The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Retinal vessel segmentation using the 2-D Gabor wavelet and supervised classification
Open accessAbstract
We present a method for automated segmentation of the vasculature in retinal images. The method produces segmentations by classifying each image pixel as vessel or nonvessel, based on the pixel's feature vector. Feature vectors are composed of the pixel's intensity and two-dimensional Gabor wavelet transform responses taken at multiple scales. The Gabor wavelet is capable of tuning to specific frequencies, thus allowing noise filtering and vessel enhancement in a single step. We use a Bayesian classifier with class-conditional probability density functions (likelihoods) described as Gaussian mixtures, yielding a fast classification, while being able to model complex decision surfaces. The probability distributions are estimated based on a training set of labeled pixels obtained from manual segmentations. The method's performance is evaluated on publicly available DRIVE (Staal et al., 2004) and STARE (Hoover et al., 2000) databases of manually labeled images. On the DRIVE database, it achieves an area under the receiver operating characteristic curve of 0.9614, being slightly superior than that presented by state-of-the-art approaches. We are making our implementation available as open source MATLAB scripts for researchers interested in implementation details, evaluation, or development of methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2012) · Encyclopedia of the Sciences of Learning · doi:10.1007/978-1-4419-1428-6_5195 · Cited by 19,370
Russell, E. L., Chiang, L. H., & Braatz, R. D. (2000) · Advances in Industrial Control · doi:10.1007/978-1-4471-0409-4_3 · Cited by 7,862
Digital Image Processing: PIKS Inside
Pratt, W. K. (2002) · Wiley eBooks · doi:10.1002/0471221325 · Cited by 4,340
Ridge-based vessel segmentation in color images of the retina
Staal, J., Abramoff, M. D., Niemeijer, M., Viergever, M. A., & van Ginneken, B. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.825627 · Cited by 4,202
Texture features for browsing and retrieval of image data
Manjunath, B. S., & Ma, W. Y. (1996) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.531803 · Cited by 3,727
Wavelets and signal processing
Rioul, O., & Vetterli, M. (1991) · IEEE Signal Processing Magazine · doi:10.1109/79.91217 · Cited by 2,786
Locating blood vessels in retinal images by piecewise threshold probing of a matched filter response
Hoover, A. D., Kouznetsova, V., & Goldbaum, M. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.845178 · Cited by 2,582
Digital image processing (2nd ed.)
(1992) · CVGIP: Image Understanding · doi:10.1016/1049-9660(92)90019-y · Cited by 1,780
Detection of blood vessels in retinal images using two-dimensional matched filters
Chaudhuri, S., Chatterjee, S., Katz, N., Nelson, M., & Goldbaum, M. (1989) · IEEE Transactions on Medical Imaging · doi:10.1109/42.34715 · Cited by 1,668
Image representation using 2D Gabor wavelets
Lee, T. S. (1996) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.541406 · Cited by 1,629
Segmentation of vessel-like patterns using mathematical morphology and curvature evaluation
Zana, F., & Klein, J.-C. (2001) · IEEE Transactions on Image Processing · doi:10.1109/83.931095 · Cited by 862
Clinical Ophthalmology: A Systematic Approach
(1991) · Archives of Ophthalmology · doi:10.1001/archopht.1991.01080100041028 · Cited by 852
Comparative study of retinal vessel segmentation methods on a new publicly available database
Niemeijer, M., Staal, J., van Ginneken, B., Loog, M., & Abramoff, M. D. (2004) · SPIE Proceedings · doi:10.1117/12.535349 · Cited by 790
Sinthanayothin, C., Boyce, J. F., Cook, H. L., & Williamson, T. H. (1999) · British Journal of Ophthalmology · doi:10.1136/bjo.83.8.902 · Cited by 778
Shape Analysis and Classification: Theory and Practice
da Fontoura Costa, L., & Cesar Jr., R. M. (2010) · CRC Press eBooks · doi:10.1201/9781420037555 · Cited by 700
Jiang, X., & Mojon, D. (2003) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2003.1159954 · Cited by 679
Can, A., Shen, H., Turner, Tanenbaum, & Roysam (1999) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/4233.767088 · Cited by 434
T-snakes: Topology adaptive snakes
McInerney, T., & Terzopoulos, D. (2000) · Medical Image Analysis · doi:10.1016/s1361-8415(00)00008-6 · Cited by 418
Flux maximizing geometric flows
Vasilevskiy, A., & Siddiqi, K. (2002) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2002.1114849 · Cited by 383
A fuzzy vessel tracking algorithm for retinal images based on fuzzy clustering
Tolias, Y. A., & Panas, S. M. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.700738 · Cited by 365
Clinical Ophthalmology. A Systematic Approach
(1989) · Annals of Internal Medicine · doi:10.7326/0003-4819-111-12-1052_4 · Cited by 352
Gang, L., Chutatape, O., & Krishnan, S. M. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.979356 · Cited by 294
The detection and quantification of retinopathy using digital angiograms
Zhou, L., Rzeszotarski, M. S., Singerman, L. J., & Chokreff, J. M. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363106 · Cited by 292
Image analysis with two-dimensional continuous wavelet transform
Antoine, J.-P., Carrette, P., Murenzi, R., & Piette, B. (1993) · Signal Processing · doi:10.1016/0165-1684(93)90085-o · Cited by 277
Diagnosis of Diabetic Eye Disease
Sussman, E. J. (1982) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1982.03320480047025 · Cited by 266
Measurement of Retinal Vessel Widths From Fundus Images Based on 2-D Modeling
Lowell, J., Hunter, A., Steel, D., Basu, A., Ryder, R., & Kennedy, R. L. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.830524 · Cited by 255
World blindness: a 21st century perspective
Taylor, H. R. (2001) · British Journal of Ophthalmology · doi:10.1136/bjo.85.3.261 · Cited by 254
Retinal blood vessel detection and tracking by matched Gaussian and Kalman filters
Chutatape, O., Zheng, L., & Krishnan, S. M. (2002) · Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Vol.20 Biomedical Engineering Towards the Year 2000 and Beyond (Cat. No.98CH36286) · doi:10.1109/iembs.1998.746160 · Cited by 228
Retinopathy and Risk of Congestive Heart Failure
Wong, T. Y. (2005) · JAMA · doi:10.1001/jama.293.1.63 · Cited by 227
Retinal Blood Vessel Segmentation by Means of Scale-Space Analysis and Region Growing
Martínez-Pérez, M. E., Hughes, A. D., Stanton, A. V., Thom, S. A., Bharath, A. A., & Parker, K. H. (1999) · Lecture Notes in Computer Science · doi:10.1007/10704282_10 · Cited by 200
Arnéodo, A., Decoster, N., & Roux, S. G. (2000) · The European Physical Journal B · doi:10.1007/s100510051161 · Cited by 185
Empirical evaluation techniques in computer vision
Bowyer, K. W., & Phillips, P. J. (1998) · Medical Entomology and Zoology · Cited by 167
Back-propagation network and its configuration for blood vessel detection in angiograms
Nekovei, R., & Sun, Y. (1995) · IEEE Transactions on Neural Networks · doi:10.1109/72.363449 · Cited by 159
Integrated wavelet processing and spatial statistical testing of fMRI data
Ville, D. V. D., Blu, T., & Unser, M. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.056 · Cited by 78
Cornforth, D. J., Jelinek, H. F., Cree, M. J., Leandro, J. J. G., Soares, J. V. B., & Junior, R. M. C. (2009) · Studies in computational intelligence · doi:10.1007/978-3-540-95978-6_12 · Cited by 41
Self-citationAngiography and Plaque Imaging: Advanced Segmentation Techniques
Suri, J. S., & Laxminarayan, S. (2007) · Cited by 34
A wavelet subspace method for real-time face tracking
Feris, R. S., Krueger, V., & Junior, R. M. C. (2004) · Real-Time Imaging · doi:10.1016/j.rti.2004.06.002 · Cited by 32
Performance Analysis of Oriented Feature Detectors
Ayres, F. J., & Rangayyan, R. M. (2005) · Brazilian Symposium on Computer Graphics and Image Processing (SIBGRAPI) · doi:10.1109/sibgrapi.2005.38 · Cited by 21
Cited by
Retinal Imaging and Image Analysis
Abramoff, M. D., Garvin, M. K., & Sonka, M. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084567 · Cited by 1,439
Ilastik: Interactive learning and segmentation toolkit
Sommer, C., Straehle, C., Kothe, U., & Hamprecht, F. A. (2011) · 2011 IEEE International Symposium on Biomedical Imaging: From Nano to Macro · doi:10.1109/isbi.2011.5872394 · Cited by 1,125
An Ensemble Classification-Based Approach Applied to Retinal Blood Vessel Segmentation
Fraz, M. M., Remagnino, P., Hoppe, A., Uyyanonvara, B., Rudnicka, A. R., Owen, C. G., & Barman, S. A. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2205687 · Cited by 1,031
Blood vessel segmentation methodologies in retinal images – A survey
Fraz, M. M., Remagnino, P., Hoppe, A., Uyyanonvara, B., Rudnicka, A. R., Owen, C. G., & Barman, S. A. (2012) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2012.03.009 · Cited by 1,001
Marín, D., Aquino, A., Gegundez-Arias, M. E., & Bravo, J. M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2064333 · Cited by 929
Metadata
- Authors
- Soares, J. V. B., Leandro, J. J. G., Cesar, R. M., Jelinek, H. F., & Cree, M. J.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2006-09
- Volume
- 25
- Issue
- 9
- Pages
- 1214-1222
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2163344010
- Cited by
- 1,497
- References
- 38
- FWCI
- 25.69
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.