The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
A Novel Method for the Automatic Grading of Retinal Vessel Tortuosity
Abstract
Tortuosity is among the first alterations in the retinal vessel network to appear in many retinopathies, such as those due to hypertension. An automatic evaluation of retinal vessel tortuosity would help the early detection of such retinopathies. Quite a few techniques for tortuosity measurement and classification have been proposed, but they do not always match the clinical concept of tortuosity. This justifies the need for a new definition, able to express in mathematical terms the tortuosity as perceived by ophthalmologists. We propose here a new algorithm for the evaluation of tortuosity in vessels recognized in digital fundus images. It is based on partitioning each vessel in segments of constant-sign curvature and then combining together each evaluation of such segments and their number. The algorithm has been compared with other available tortuosity measures on a set of 30 arteries and one of 30 veins from 60 different images. These vessels had been preliminarily ordered by a retina specialist by increasing perceived tortuosity. The proposed algorithm proved to be the best one in matching the clinically perceived vessel tortuosity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ridge-based vessel segmentation in color images of the retina
Staal, J., Abramoff, M. D., Niemeijer, M., Viergever, M. A., & van Ginneken, B. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.825627 · Cited by 4,202
Locating blood vessels in retinal images by piecewise threshold probing of a matched filter response
Hoover, A. D., Kouznetsova, V., & Goldbaum, M. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.845178 · Cited by 2,582
Detection of blood vessels in retinal images using two-dimensional matched filters
Chaudhuri, S., Chatterjee, S., Katz, N., Nelson, M., & Goldbaum, M. (1989) · IEEE Transactions on Medical Imaging · doi:10.1109/42.34715 · Cited by 1,668
Wong, T. Y., Klein, R., Couper, D. J., Cooper, L. S., Shahar, E., Hubbard, L. D., Wofford, M. R., & Sharrett, A. R. (2001) · The Lancet · doi:10.1016/s0140-6736(01)06253-5 · Cited by 781
Girard, B. (2008) · Cited by 616
Automatic detection of diabetic retinopathy using an artificial neural network: a screening tool.
Gardner, G. G., Keating, D., Williamson, T. H., & Elliott, A. T. (1996) · British Journal of Ophthalmology · doi:10.1136/bjo.80.11.940 · Cited by 508
Detection of Optic Disc in Retinal Images by Means of a Geometrical Model of Vessel Structure
Foracchia, M., Grisan, E., & Ruggeri, A. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.829331 · Cited by 445
Self-citationCan, A., Shen, H., Turner, Tanenbaum, & Roysam (1999) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/4233.767088 · Cited by 434
Measuring tortuosity of the intracerebral vasculature from MRA images
Bullitt, E., Gerig, G., Pizer, S. M., Lin, W., & Aylward, S. R. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.816964 · Cited by 419
A fuzzy vessel tracking algorithm for retinal images based on fuzzy clustering
Tolias, Y. A., & Panas, S. M. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.700738 · Cited by 365
Heneghan, C. (2002) · Medical Image Analysis · doi:10.1016/s1361-8415(02)00058-0 · Cited by 353
Measurement and classification of retinal vascular tortuosity
Hart, W. E., Goldbaum, M., Côté, B., Kube, P., & Nelson, M. R. (1999) · International Journal of Medical Informatics · doi:10.1016/s1386-5056(98)00163-4 · Cited by 328
EVALUATION OF OPHTHALMOSCOPIC CHANGES OF HYPERTENSION AND ARTERIOLAR SCLEROSIS
SCHEIE, H. G. (1953) · Archives of Ophthalmology · doi:10.1001/archopht.1953.00920020122001 · Cited by 268
Retinal vascular tree morphology: a semi-automatic quantification
Martinez-Perez, M. E., Highes, A. D., Stanton, A. V., Thorn, S. A., Chapman, N., Bharath, A. A., & Parker, K. H. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.800789 · Cited by 241
Vascular network changes in the retina with age and hypertension.
Stanton, A. V., Wasan, B. S., Cerutti, A., Ford, S. R., Marsh, R. J., Sever, P., Thom, S., & Hughes, A. D. (1995) · PubMed · Cited by 200
Vascular network changes in the retina with age and hypertension
Wasan, B. S., Cerutti, A., Ford, S., & Marsh, R. (1995) · Journal of Hypertension · doi:10.1097/00004872-199512010-00039 · Cited by 69
Cited by
Trainable COSFIRE filters for vessel delineation with application to retinal images
Azzopardi, G., Strisciuglio, N., Vento, M., & Petkov, N. (2015) · Medical Image Analysis · doi:10.1016/j.media.2014.08.002 · Cited by 713
Brown, J. M., Campbell, J. P., Beers, A., Chang, K., Ostmo, S., Chan, R. V. P., Dy, J., Erdogmus, D., Ioannidis, S., Kalpathy-Cramer, J., et al. (2018) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2018.1934 · Cited by 657
Twisted Blood Vessels: Symptoms, Etiology and Biomechanical Mechanisms
Han, H.-C. (2012) · Journal of Vascular Research · doi:10.1159/000335123 · Cited by 489
Odstrcilik, J., Kolar, R., Budai, A., Hornegger, J., Jan, J., Gazarek, J., Kubena, T., Cernosek, P., Svoboda, O., & Angelopoulou, E. (2013) · IET Image Processing · doi:10.1049/iet-ipr.2012.0455 · Cited by 472
Owen, C. G., Rudnicka, A. R., Mullen, R., Barman, S. A., Monekosso, D., Whincup, P. H., Ng, J., & Paterson, C. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.08-3018 · Cited by 465
Metadata
- Authors
- Grisan, E., Foracchia, M., & Ruggeri, A.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2008-03
- Volume
- 27
- Issue
- 3
- Pages
- 310-319
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2140431812
- Cited by
- 260
- References
- 16
- FWCI
- 6.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.