The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Automated 3-D Intraretinal Layer Segmentation of Macular Spectral-Domain Optical Coherence Tomography Images
Open accessAbstract
With the introduction of spectral-domain optical coherence tomography (OCT), much larger image datasets are routinely acquired compared to what was possible using the previous generation of time-domain OCT. Thus, the need for 3-D segmentation methods for processing such data is becoming increasingly important. We report a graph-theoretic segmentation method for the simultaneous segmentation of multiple 3-D surfaces that is guaranteed to be optimal with respect to the cost function and that is directly applicable to the segmentation of 3-D spectral OCT image data. We present two extensions to the general layered graph segmentation method: the ability to incorporate varying feasibility constraints and the ability to incorporate true regional information. Appropriate feasibility constraints and cost functions were learned from a training set of 13 spectral-domain OCT images from 13 subjects. After training, our approach was tested on a test set of 28 images from 14 subjects. An overall mean unsigned border positioning error of 5.69+/-2.41 microm was achieved when segmenting seven surfaces (six layers) and using the average of the manual tracings of two ophthalmologists as the reference standard. This result is very comparable to the measured interobserver variability of 5.71+/-1.98 microm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Interactive graph cuts for optimal boundary & region segmentation of objects in N-D images
Boykov, Y. Y., & Jolly, M.-P. (2002) · Proceedings Eighth IEEE International Conference on Computer Vision. ICCV 2001 · doi:10.1109/iccv.2001.937505 · Cited by 3,674
Speckle reducing anisotropic diffusion
Yu, Y., & Acton, S. T. (2002) · IEEE Transactions on Image Processing · doi:10.1109/tip.2002.804276 · Cited by 1,850
de Boer, J. F., Cense, B., Park, B. H., Pierce, M. C., Tearney, G. J., & Bouma, B. E. (2003) · Optics Letters · doi:10.1364/ol.28.002067 · Cited by 1,250
In vivo human retinal imaging by Fourier domain optical coherence tomography
Wojtkowski, M., Leitgeb, R., Kowalczyk, A., Bajraszewski, T., & Fercher, A. F. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1482379 · Cited by 913
State-of-the-art retinal optical coherence tomography
DREXLER, W., & FUJIMOTO, J. (2008) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2007.07.005 · Cited by 906
Optimal Surface Segmentation in Volumetric Images-A Graph-Theoretic Approach
Li, K., Wu, X., Chen, D. Z., & Sonka, M. (2006) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2006.19 · Cited by 664
Self-citationMacular Segmentation with Optical Coherence Tomography
Ishikawa, H., Stein, D. M., Wollstein, G., Beaton, S., Fujimoto, J. G., & Schuman, J. S. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-0335 · Cited by 498
van Dijk, H. W., Kok, P. H. B., Garvin, M., Sonka, M., DeVries, J. H., Michels, R. P. J., van Velthoven, M. E. J., Schlingemann, R. O., Verbraak, F. D., & Abra`moff, M. D. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.08-3143 · Cited by 367
Self-citationGarvin, M. K., Abramoff, M. D., Kardon, R., Russell, S. R., Wu, X., & Sonka, M. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.923966 · Cited by 336
Self-citationAutomated detection of retinal layer structures on optical coherence tomography images
DeBuc, D. C., Salinas, H. M., & Puliafito, C. A. (2005) · Optics Express · doi:10.1364/opex.13.010200 · Cited by 288
Retinal thickness measurements from optical coherence tomography using a Markov boundary model
Koozekanani, D., Boyer, K., & Roberts, C. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.952728 · Cited by 231
Approximate Thin Plate Spline Mappings
Donato, G., & Belongie, S. (2002) · Lecture Notes in Computer Science · doi:10.1007/3-540-47977-5_2 · Cited by 228
Quantitative Thickness Measurement of Retinal Layers Imaged by Optical Coherence Tomography
Shahidi, M., Wang, Z., & Zelkha, R. (2005) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2005.01.012 · Cited by 130
A Scalable graph-cut algorithm for N-D grids
Delong, A., & Boykov, Y. Y. (2008) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr.2008.4587464 · Cited by 130
Delineating fluid-filled region boundaries in optical coherence tomography images of the retina
Fernandez, D. C. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.848655 · Cited by 124
Segmentation of Three-dimensional Retinal Image Data
Fuller, A. R., Zawadzki, R. J., Choi, S., Wiley, D. F., Werner, J. S., & Hamann, B. (2007) · IEEE Transactions on Visualization and Computer Graphics · doi:10.1109/tvcg.2007.70590 · Cited by 87
Towards quantitative analysis of retinal features in optical coherence tomography
Baroni, M., Fortunato, P., & Torre, A. L. (2006) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.06.003 · Cited by 84
QUANTIFICATION OF PHOTORECEPTOR LAYER THICKNESS IN NORMAL EYES USING OPTICAL COHERENCE TOMOGRAPHY
Chan, A. Y., Duker, J. S., Ishikawa, H., Ko, T. H., Schuman, J. S., & Fujimoto, J. G. (2006) · Retina · doi:10.1097/00006982-200607000-00011 · Cited by 61
Cited by
Unsupervised Anomaly Detection with Generative Adversarial Networks to Guide Marker Discovery
Schlegl, T., Seeböck, P., Waldstein, S. M., Schmidt-Erfurth, U., & Langs, G. (2017) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-59050-9_12 · Cited by 2,627
f-AnoGAN: Fast unsupervised anomaly detection with generative adversarial networks
Schlegl, T., Seeböck, P., Waldstein, S. M., Langs, G., & Schmidt-Erfurth, U. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.01.010 · Cited by 1,545
Retinal Imaging and Image Analysis
Abramoff, M. D., Garvin, M. K., & Sonka, M. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084567 · Cited by 1,439
Self-citationChiu, S. J., Li, X. T., Nicholas, P., Toth, C. A., Izatt, J. A., & Farsiu, S. (2010) · Optics Express · doi:10.1364/oe.18.019413 · Cited by 733
Fully Automated Detection and Quantification of Macular Fluid in OCT Using Deep Learning
Schlegl, T., Waldstein, S. M., Bogunovic, H., Endstraßer, F., Sadeghipour, A., Philip, A.-M., Podkowinski, D., Gerendas, B. S., Langs, G., & Schmidt-Erfurth, U. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2017.10.031 · Cited by 597
Metadata
- Authors
- Garvin, M. K., Abramoff, M. D., Wu, X., Russell, S. R., Burns, T. L., & Sonka, M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2009-09
- Volume
- 28
- Issue
- 9
- Pages
- 1436-1447
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2127318120
- Cited by
- 626
- References
- 18
- FWCI
- 13.15
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.