The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Automated 3-D Intraretinal Layer Segmentation of Macular Spectral-Domain Optical Coherence Tomography Images
Open accessAbstract
With the introduction of spectral-domain optical coherence tomography (OCT), much larger image datasets are routinely acquired compared to what was possible using the previous generation of time-domain OCT. Thus, the need for 3-D segmentation methods for processing such data is becoming increasingly important. We report a graph-theoretic segmentation method for the simultaneous segmentation of multiple 3-D surfaces that is guaranteed to be optimal with respect to the cost function and that is directly applicable to the segmentation of 3-D spectral OCT image data. We present two extensions to the general layered graph segmentation method: the ability to incorporate varying feasibility constraints and the ability to incorporate true regional information. Appropriate feasibility constraints and cost functions were learned from a training set of 13 spectral-domain OCT images from 13 subjects. After training, our approach was tested on a test set of 28 images from 14 subjects. An overall mean unsigned border positioning error of 5.69+/-2.41 microm was achieved when segmenting seven surfaces (six layers) and using the average of the manual tracings of two ophthalmologists as the reference standard. This result is very comparable to the measured interobserver variability of 5.71+/-1.98 microm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Interactive graph cuts for optimal boundary & region segmentation of objects in N-D images
Boykov, Y. Y., & Jolly, M.-P. (2002) · Proceedings Eighth IEEE International Conference on Computer Vision. ICCV 2001 · doi:10.1109/iccv.2001.937505 · Cited by 3,674
Speckle reducing anisotropic diffusion
Yu, Y., & Acton, S. T. (2002) · IEEE Transactions on Image Processing · doi:10.1109/tip.2002.804276 · Cited by 1,850
de Boer, J. F., Cense, B., Park, B. H., Pierce, M. C., Tearney, G. J., & Bouma, B. E. (2003) · Optics Letters · doi:10.1364/ol.28.002067 · Cited by 1,250
In vivo human retinal imaging by Fourier domain optical coherence tomography
Wojtkowski, M., Leitgeb, R., Kowalczyk, A., Bajraszewski, T., & Fercher, A. F. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1482379 · Cited by 913
State-of-the-art retinal optical coherence tomography
DREXLER, W., & FUJIMOTO, J. (2008) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2007.07.005 · Cited by 906
Optimal Surface Segmentation in Volumetric Images-A Graph-Theoretic Approach
Li, K., Wu, X., Chen, D. Z., & Sonka, M. (2006) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2006.19 · Cited by 664
Self-citationMacular Segmentation with Optical Coherence Tomography
Ishikawa, H., Stein, D. M., Wollstein, G., Beaton, S., Fujimoto, J. G., & Schuman, J. S. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-0335 · Cited by 498
van Dijk, H. W., Kok, P. H. B., Garvin, M., Sonka, M., DeVries, J. H., Michels, R. P. J., van Velthoven, M. E. J., Schlingemann, R. O., Verbraak, F. D., & Abra`moff, M. D. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.08-3143 · Cited by 367
Self-citationGarvin, M. K., Abramoff, M. D., Kardon, R., Russell, S. R., Wu, X., & Sonka, M. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.923966 · Cited by 336
Self-citationAutomated detection of retinal layer structures on optical coherence tomography images
DeBuc, D. C., Salinas, H. M., & Puliafito, C. A. (2005) · Optics Express · doi:10.1364/opex.13.010200 · Cited by 288
Cited by
Unsupervised Anomaly Detection with Generative Adversarial Networks to Guide Marker Discovery
Schlegl, T., Seeböck, P., Waldstein, S. M., Schmidt-Erfurth, U., & Langs, G. (2017) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-59050-9_12 · Cited by 2,627
f-AnoGAN: Fast unsupervised anomaly detection with generative adversarial networks
Schlegl, T., Seeböck, P., Waldstein, S. M., Langs, G., & Schmidt-Erfurth, U. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.01.010 · Cited by 1,545
Retinal Imaging and Image Analysis
Abramoff, M. D., Garvin, M. K., & Sonka, M. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084567 · Cited by 1,439
Self-citationChiu, S. J., Li, X. T., Nicholas, P., Toth, C. A., Izatt, J. A., & Farsiu, S. (2010) · Optics Express · doi:10.1364/oe.18.019413 · Cited by 733
Fully Automated Detection and Quantification of Macular Fluid in OCT Using Deep Learning
Schlegl, T., Waldstein, S. M., Bogunovic, H., Endstraßer, F., Sadeghipour, A., Philip, A.-M., Podkowinski, D., Gerendas, B. S., Langs, G., & Schmidt-Erfurth, U. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2017.10.031 · Cited by 597
Mwanza, J.-C., Oakley, J. D., Budenz, D. L., Chang, R. T., Knight, O. J., & Feuer, W. J. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-7962 · Cited by 429
A paradigm shift in imaging biomarkers in neovascular age-related macular degeneration
Schmidt-Erfurth, U., & Waldstein, S. M. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.07.007 · Cited by 390
“Obviously, a precise automated quantification of the relevant retinal morphologic lesions is necessary, but currently only achieved for fewmorphologic factors (Garvin et al., 2009; Schlegl et al., 2015; Xu et al., 2015b; Zhang et al., 2012; Zhang et al., 2014).”
BackgroundDecreased Retinal Ganglion Cell Layer Thickness in Patients with Type 1 Diabetes
van Dijk, H. W., Verbraak, F. D., Kok, P. H. B., Garvin, M. K., Sonka, M., Lee, K., DeVries, J. H., Michels, R. P. J., van Velthoven, M. E. J., Schlingemann, R. O., et al. (2010) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.09-5041 · Cited by 359
Self-citationEarly Neurodegeneration in the Retina of Type 2 Diabetic Patients
van Dijk, H. W., Verbraak, F. D., Kok, P. H. B., Stehouwer, M., Garvin, M. K., Sonka, M., DeVries, J. H., Schlingemann, R. O., & Abràmoff, M. D. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-8997 · Cited by 358
Self-citationRetinal layer segmentation of macular OCT images using boundary classification
Lang, A., Carass, A., Hauser, M., Sotirchos, E. S., Calabresi, P. A., Ying, H. S., & Prince, J. L. (2013) · Biomedical Optics Express · doi:10.1364/boe.4.001133 · Cited by 310
Automated layer segmentation of macular OCT images using dual-scale gradient information
Yang, Q., Reisman, C. A., Wang, Z., Fukuma, Y., Hangai, M., Yoshimura, N., Tomidokoro, A., Araie, M., Raza, A. S., Hood, D. C., et al. (2010) · Optics Express · doi:10.1364/oe.18.021293 · Cited by 284
RETOUCH: The Retinal OCT Fluid Detection and Segmentation Benchmark and Challenge
Bogunovic, H., Venhuizen, F., Klimscha, S., Apostolopoulos, S., Bab-Hadiashar, A., Bagci, U., Beg, M. F., Bekalo, L., Chen, Q., Ciller, C., et al. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2901398 · Cited by 273
Exploiting epistemic uncertainty of anatomy segmentation for anomaly detection in retinal OCT
Seebock, P., Orlando, J. I., Schlegl, T., Waldstein, S. M., Bogunovic, H., Klimscha, S., Langs, G., & Schmidt-Erfurth, U. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2919951 · Cited by 164
Structured layer surface segmentation for retina OCT using fully convolutional regression networks
He, Y., Carass, A., Liu, Y., Jedynak, B. M., Solomon, S. D., Saidha, S., Calabresi, P. A., & Prince, J. L. (2021) · Medical Image Analysis · doi:10.1016/j.media.2020.101856 · Cited by 104
“…level sets (Carass et al., 2014; Novosel et al., 2015; Carass and Prince, 2016; Novosel et al., 2017; Liu et al., 2018, 2019) or graph methods (Garvin et al., 2009; Chiu et al., 2010; Lang et al., 2013, 2014, 2015; Antony et al., 2014, 2016b; Lang et al., 2017) to obtain final smooth,…”
MethodOrlando, J. I., Seebock, P., Bogunovic, H., Klimscha, S., Grechenig, C., Waldstein, S., Gerendas, B. S., & Schmidt-Erfurth, U. (2019) · 2019 IEEE 16th International Symposium on Biomedical Imaging (ISBI 2019) · doi:10.1109/isbi.2019.8759581 · Cited by 65
Metadata
- Authors
- Garvin, M. K., Abramoff, M. D., Wu, X., Russell, S. R., Burns, T. L., & Sonka, M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2009-09
- Volume
- 28
- Issue
- 9
- Pages
- 1436-1447
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2127318120
- Cited by
- 626
- References
- 18
- FWCI
- 13.15
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.