MsCNN: A Deep Learning Framework for P300-Based Brain–Computer Interface Speller
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
In this paper, a novel multiscale convolutional neural network (MsCNN) architecture is proposed for P300 based BCI speller. Major limitation of BCI system is that it requires a large number of data to train the system. However, collection of large amount of data from a single subject makes the task tedious for the subject and this will affect the quality of the acquired electroencephalogram (EEG) signal. To cope with this issues, a MsCNN model with transfer learning (MsCNN-TL) technique is proposed in this work for improvement of the P300 based character recognition performance with limited amount of training data. The multi-resolution deep features are extracted from the fully connected layer of the trained MsCNN-TL architecture. These deep features are optimized using Fisher ratio (F-ratio) based feature selection technique and the optimal features are applied to the ensemble of support vector machines (ESVMs) for P300 detection. The proposed method is tested on BCI competition datasets and it achieves better performance compared to the other state-of-the-art techniques for limited training dataset.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 1×
“In 1988, Farwell and Donchin developed this type of P300 speller paradigm [31].”
BackgroundBrain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
The novelty P3: an event-related brain potential (ERP) sign of the brain's evaluation of novelty
Friedman, D., Cycowicz, Y. M., & Gaeta, H. (2001) · Neuroscience & Biobehavioral Reviews · doi:10.1016/s0149-7634(01)00019-7 · Cited by 1,282 · cited 1×
“The signal is called as P300 because a positive peak is appeared after 300 ms of the stimulus [6].”
BackgroundThe BCI competition III: validating alternative approaches to actual BCI problems
Blankertz, B., Muller, K.-R., Krusienski, D. J., Schalk, G., Wolpaw, J. R., Schlogl, A., Pfurtscheller, G., Millan, J. R., Schroder, M., & Birbaumer, N. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875642 · Cited by 927
Convolutional Neural Networks for P300 Detection with Application to Brain-Computer Interfaces
Cecotti, H., & Graser, A. (2011) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2010.125 · Cited by 778
Blankertz, B., Muller, K.-R., Curio, G., Vaughan, T. M., Schalk, G., Wolpaw, J. R., Schlogl, A., Neuper, C., Pfurtscheller, G., Hinterberger, T., et al. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826692 · Cited by 670
BCI competition III: Dataset II—Ensemble of SVMs for BCI P300 speller
Rakotomamonjy, A., & Guigue, V. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.915728 · Cited by 512 · cited 4×
“To minimise the classifier variability and error, ensemble of classifiers technique is adopted in BCI system [11].”
BackgroundMethodInfluentialJayaram, V., Alamgir, M., Altun, Y., Scholkopf, B., & Grosse-Wentrup, M. (2016) · IEEE Computational Intelligence Magazine · doi:10.1109/mci.2015.2501545 · Cited by 468 · cited 3×
“In addition, requirement of long calibration time for the network due to the large variability of EEG signals restricts the use of BCI in real time application for both patients and healthy subjects [27], [28].”
BackgroundMethodLotte, F. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2404941 · Cited by 327 · cited 1×
“In addition, requirement of long calibration time for the network due to the large variability of EEG signals restricts the use of BCI in real time application for both patients and healthy subjects [27], [28].”
BackgroundDeep learning based on Batch Normalization for P300 signal detection
Liu, M., Wu, W., Gu, Z., Yu, Z., Qi, F., & Li, Y. (2018) · Neurocomputing · doi:10.1016/j.neucom.2017.08.039 · Cited by 230 · cited 7×
“It is observed from Tables III and V that with limited amount of training data, the proposed MsCNN-TL-ESVM technique shows better performance compared to the other methods [7], [12], [14], [17], [20], [36].”
BackgroundMethodResultInfluential
Cited by
A review on transfer learning in EEG signal analysis
Wan, Z., Yang, R., Huang, M., Zeng, N., & Liu, X. (2021) · Neurocomputing · doi:10.1016/j.neucom.2020.09.017 · Cited by 468
Review of Machine Learning Techniques for EEG Based Brain Computer Interface
Aggarwal, S., & Chugh, N. (2022) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-021-09684-6 · Cited by 270
Wang, Z., Chen, C., Li, J., Wan, F., Sun, Y., & Wang, H. (2023) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2023.3237319 · Cited by 75
“6) MsCNN-TL-ESVM was proposed by Sourav Kundu and Samit Ari [41].”
MethodA systematic deep learning model selection for p300-based brain-computer interfaces
Abibullaev, B., & Zollanvari, A. (2022) · IEEE Transactions on Systems Man and Cybernetics Systems · doi:10.1109/tsmc.2021.3051136 · Cited by 53
Aghili, S. N., & Erfanian, A. (2023) · IEEE Access · doi:10.1109/access.2023.3313260 · Cited by 12
Metadata
- Authors
- Kundu, S., & Ari, S.
- Venue
- IEEE Transactions on Medical Robotics and Bionics
- Published
- 2020-02
- Volume
- 2
- Issue
- 1
- Pages
- 86-93
- ISSN
- 2576-3202 (ISSN-L)
- OpenAlex
- W2996546005
- Cited by
- 70
- References
- 11
- FWCI
- 2.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: MsCNN: A Deep Learning Framework for P300-Based Brain–Computer Interface Speller. https://app.cochat.ai/papers/10.1109/tmrb.2019.2959559
- The paper
- Kundu, S., & Ari, S. (2020). MsCNN: A Deep Learning Framework for P300-Based Brain–Computer Interface Speller. IEEE Transactions on Medical Robotics and Bionics. https://doi.org/10.1109/tmrb.2019.2959559
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.