Design of a Dual-Band Implantable Antenna and Development of Skin Mimicking Gels for Continuous Glucose Monitoring
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
In this study, we present a small-size dual medical implant communications service (MICS) (402-405 MHz) and industrial, scientific, and medical (ISM) (2.4-2.48 GHz) band implantable antenna for continuous glucose-monitoring applications. The antenna is optimized for dual-band operation by combining an in-house finite-element boundary integral electromagnetic simulation code and particle swarm optimization algorithm. In order to test the designed antenna in vitro, gels mimicking the electrical properties of human skin are also developed. The optimized antenna is fabricated and measured in the gel. The simulated and measured bandwidths are found to be 20.4% MICS, 4.2% ISM, and 35.3% MICS, and 7.1% ISM, respectively. Although we have emphasized continuous glucose monitoring throughout this paper, the antenna and skin mimicking gels presented here can be used for many other wireless telemetry applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kennedy, J., & Eberhart, R. (2002) · Proceedings of ICNN'95 - International Conference on Neural Networks · doi:10.1109/icnn.1995.488968 · Cited by 58,192
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/002 · Cited by 4,270
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175 · cited 1×
“In [32], the electrical properties of the skin at 402 MHz and 2.4 GHz were found to be , S m and , S m, respectively.”
BackgroundInfluentialThe dielectric properties of biological tissues: I. Literature survey
Gabriel, C., Gabriel, S., & Corthout, E. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/001 · Cited by 3,156
Particle swarm optimization in electromagnetics
Robinson, J., & Rahmat-Samii, Y. (2004) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2004.823969 · Cited by 2,265
Implanted Antennas Inside a Human Body: Simulations, Designs, and Characterizations
Kim, J., & Rahmat-Samii, Y. (2004) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2004.832018 · Cited by 757
Design of Implantable Microstrip Antenna for Communication With Medical Implants
Soontornpipit, P., Furse, C. M., & Chung, Y. C. (2004) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2004.831976 · Cited by 472
Tissue-mimicking phantom materials for narrowband and ultrawideband microwave applications
Lazebnik, M., Madsen, E. L., Frank, G. R., & Hagness, S. C. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/18/001 · Cited by 418
Formulas for preparing phantom muscle tissue at various radiofrequencies
Chou, C., Chen, G., Guy, A. W., & Luk, K. H. (1984) · Bioelectromagnetics · doi:10.1002/bem.2250050408 · Cited by 253
Implantable myoelectric sensors (IMES) for upper-extremity prosthesis control- preliminary work
Weir, R. F. F., Troyk, P. R., DeMichele, G. A., & Kuiken, T. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1279658 · Cited by 72
Cited by
Detecting Vital Signs with Wearable Wireless Sensors
Yilmaz, T., Foster, R., & Hao, Y. (2010) · Sensors · doi:10.3390/s101210837 · Cited by 344
Kiourti, A., & Nikita, K. S. (2012) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2012.2201078 · Cited by 337
Liu, C., Guo, Y.-X., & Xiao, S. (2014) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2014.2307341 · Cited by 316
Huang, F.-J., Lee, C.-M., Chang, C.-L., Chen, L.-K., Yo, T.-C., & Luo, C.-H. (2011) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2011.2152317 · Cited by 268
Design and Safety Considerations of an Implantable Rectenna for Far-Field Wireless Power Transfer
Liu, C., Guo, Y.-X., Sun, H., & Xiao, S. (2014) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2014.2352363 · Cited by 234
“A dual-band antenna was studied in [6] to improve and extend the lifetime of IMDs.”
BackgroundKiourti, A., Psathas, K. A., & Nikita, K. S. (2014) · Bioelectromagnetics · doi:10.1002/bem.21813 · Cited by 209
“Suggested ideas include pre-configured on-off function of the IIMD [Furse, 2009], and transmission/ detection of a “ wake-up ” alarm signal [Karacolak et al., 2008].”
MethodYilmaz, T., Foster, R., & Hao, Y. (2014) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2014.2313139 · Cited by 168
“Radio frequency (RF) techniques in the literature are mostly focused on telemetry and BGL sensing is usually performed with a chemical sensor [2]–[4].”
BackgroundWireless power transfer system for deep-implanted biomedical devices
Iqbal, A., Sura, P. R., Al-Hasan, M., Mabrouk, I. B., & Denidni, T. A. (2022) · Scientific Reports · doi:10.1038/s41598-022-18000-6 · Cited by 105
Review on medical implantable antenna technology and imminent research challenges
Soliman, M. M., Chowdhury, M. E. H., Khandakar, A., Islam, M. T., Qiblawey, Y., Musharavati, F., & Zal Nezhad, E. (2021) · Sensors · doi:10.3390/s21093163 · Cited by 95
Sani, A., Alomainy, A., & Hao, Y. (2009) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2009.2029770 · Cited by 91
Metadata
- Authors
- Karacolak, T., Hood, A. Z., & Topsakal, E.
- Venue
- IEEE Transactions on Microwave Theory and Techniques
- Published
- 2008-04
- Volume
- 56
- Issue
- 4
- Pages
- 1001-1008
- ISSN
- 0018-9480 (ISSN-L)
- 1557-9670
- OpenAlex
- W2147131164
- Cited by
- 633
- References
- 13
- FWCI
- 12.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.