CoChat

A Flat Interface Nerve Electrode With Integrated Multiplexer

Open access
Lertmanorat, Zeng, Montague, Fred W., Durand, Dominique M. · 2009 · IEEE Transactions on Neural Systems and Rehabilitation Engineering
Cited by 18

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Abstract

One of the goals of peripheral nerve cuff electrode development is the design of an electrode capable of selectively activating a specific population of axons in a common nerve trunk. Several designs such as the round spiral electrode or the flat interface nerve electrode (FINE) have shown such ability. However, multiple contact electrodes require many leads, making the implantation difficult and potentially damaging to the nerve. Taking advantage of the flat geometry of the FINE, multiplexers were embedded within the cuff electrode to reduce the number of leads needed to control 32 channels. The circuit was implemented on a polyimide film using off-the-shelf electronic components. The electronic module was surface-mounted directly onto the electrode's flat substrate. Two circuit designs were designed, built, and tested: 1) a single supply design with only two wires but limited to cathodic-first pulse and 2) a dual-supply design requiring three lead wires but an arbitrary stimulation waveform. The electrode design includes 32 contacts in a 1 mm x 8 mm opening. The contact size is 300 microm x 400 microm with access resistance less than 1 k ohm. This electrode is not intended for long-term use, but developed as a feasibility study for future development using low-water-absorption materials such as liquid crystal polymer and an application specific integrated circuit.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tnsre.2008.2009307

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

See all 18

Metadata

Authors
Lertmanorat, Z., Montague, F. W., & Durand, D. M.
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2009-04
Volume
17
Issue
2
Pages
176-182
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2133215897
Cited by
18
References
19
FWCI
0.26
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Flat Interface Nerve Electrode With Integrated Multiplexer. https://app.cochat.ai/papers/10.1109/tnsre.2008.2009307
The paper
Lertmanorat, Z., Montague, F. W., & Durand, D. M. (2009). A Flat Interface Nerve Electrode With Integrated Multiplexer. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2008.2009307

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.