A Flat Interface Nerve Electrode With Integrated Multiplexer
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
One of the goals of peripheral nerve cuff electrode development is the design of an electrode capable of selectively activating a specific population of axons in a common nerve trunk. Several designs such as the round spiral electrode or the flat interface nerve electrode (FINE) have shown such ability. However, multiple contact electrodes require many leads, making the implantation difficult and potentially damaging to the nerve. Taking advantage of the flat geometry of the FINE, multiplexers were embedded within the cuff electrode to reduce the number of leads needed to control 32 channels. The circuit was implemented on a polyimide film using off-the-shelf electronic components. The electronic module was surface-mounted directly onto the electrode's flat substrate. Two circuit designs were designed, built, and tested: 1) a single supply design with only two wires but limited to cathodic-first pulse and 2) a dual-supply design requiring three lead wires but an arbitrary stimulation waveform. The electrode design includes 32 contacts in a 1 mm x 8 mm opening. The contact size is 300 microm x 400 microm with access resistance less than 1 k ohm. This electrode is not intended for long-term use, but developed as a feasibility study for future development using low-water-absorption materials such as liquid crystal polymer and an application specific integrated circuit.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A spiral nerve cuff electrode for peripheral nerve stimulation
Naples, G. G., Mortimer, J. T., Scheiner, A., & Sweeney, J. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8670 · Cited by 415 · cited 1×
“epimysial [3], intramuscular [4], epi-neural [5]–[7], and intrafascicular electrodes [8]–[11].”
BackgroundFunctionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398 · cited 3×
“A flat interface nerve electrode (FINE) was developed to overcome this problem [16].”
BackgroundSelf-citationSelective Stimulation of Cat Sciatic Nerve Using an Array of Varying-Length Microelectrodes
Branner, A., Stein, R. B., & Normann, R. A. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.85.4.1585 · Cited by 359 · cited 2×
“epimysial [3], intramuscular [4], epi-neural [5]–[7], and intrafascicular electrodes [8]–[11].”
BackgroundSelective control of muscle activation with a multipolar nerve cuff electrode
Veraart, C., Grill, W. M., & Mortimer, J. T. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.237694 · Cited by 320 · cited 3×
“Multicontact spiral cuff electrodes have also been shown to be selective in stimulating individual fascicles in a common nerve [6], [7].”
BackgroundMethodAn implantable multielectrode array with on-chip signal processing
Najafi, K., & Wise, K. D. (1986) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1986.1052646 · Cited by 310 · cited 1×
“Integrated circuits have been used to reduce the number of interconnecting leads for both central and peripheral nerve interfaces [24], [25].”
MethodSmith, B., Tang, Z., Johnson, M. W., Pourmehdi, S., Gazdik, M. M., Buckett, J. R., & Peckham, P. H. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.664202 · Cited by 270 · cited 1×
“lating waveform for the single-supply design is limited to a cathodic-first pulse followed by low-amplitude anodic pulse, this type of stimulating waveform has been used clinically for over a decade with no complications [27], [28].”
Electrodeposited iridium oxide for neural stimulation and recording electrodes
Meyer, R. D., Cogan, S. F., Nguyen, T. H., & Rauh, R. D. (2001) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/7333.918271 · Cited by 255 · cited 1×
“However, electrodeposition of iridium oxide would be required for nerve stimulation to increase the charge injection limit and prevent metal dissolution [31].”
BackgroundLago, N., Yoshida, K., Koch, K. P., & Navarro, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886617 · Cited by 227
A nerve cuff technique for selective excitation of peripheral nerve trunk regions
Sweeney, J. D., Ksienski, D. A., & Mortimer, J. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55681 · Cited by 196
Schiefer, M. A., Triolo, R. J., & Tyler, D. J. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.918425 · Cited by 148 · cited 5×
“flat area of the electrode is a suitable location for housing an electronic module, especially for a large nerve such as a femoral nerve that is 12 mm wide and 4 mm thick [17].”
BackgroundInfluential
Cited by
A review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133
Corrosion of silicon integrated circuits and lifetime predictions in implantable electronic devices
Vanhoestenberghe, A., & Donaldson, N. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/031002 · Cited by 140
Motor-commands decoding using peripheral nerve signals: a review
Hong, K.-S., Aziz, N., & Ghafoor, U. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab383 · Cited by 63
Wu, Y., & Guo, L. (2020) · Neural Interface Engineering · doi:10.1007/978-3-030-41854-0_5 · Cited by 3
Metadata
- Authors
- Lertmanorat, Z., Montague, F. W., & Durand, D. M.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2009-04
- Volume
- 17
- Issue
- 2
- Pages
- 176-182
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2133215897
- Cited by
- 18
- References
- 19
- FWCI
- 0.26
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Flat Interface Nerve Electrode With Integrated Multiplexer. https://app.cochat.ai/papers/10.1109/tnsre.2008.2009307
- The paper
- Lertmanorat, Z., Montague, F. W., & Durand, D. M. (2009). A Flat Interface Nerve Electrode With Integrated Multiplexer. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2008.2009307
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.