Multiple Binary Classifications via Linear Discriminant Analysis for Improved Controllability of a Powered Prosthesis
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
This paper describes a novel pattern recognition based myoelectric control system that uses parallel binary classification and class specific thresholds. The system was designed with an intuitive configuration interface, similar to existing conventional myoelectric control systems. The system was assessed quantitatively with a classification error metric and functionally with a clothespin test implemented in a virtual environment. For each case, the proposed system was compared to a state-of-the-art pattern recognition system based on linear discriminant analysis and a conventional myoelectric control scheme with mode switching. These assessments showed that the proposed control system had a higher classification error ( p < 0.001) but yielded a more controllable myoelectric control system ( p < 0.001) as measured through a clothespin usability test implemented in a virtual environment. Furthermore, the system was computationally simple and applicable for real-time embedded implementation. This work provides the basis for a clinically viable pattern recognition based myoelectric control system which is robust, easily configured, and highly usable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chiang, L. H., Russell, E. L., & Braatz, R. D. (2001) · Advanced Textbooks in Control and Signal Processing · doi:10.1007/978-1-4471-0347-9_3 · Cited by 5,003
Adaptive Control Processes: A Guided Tour
Bellman, R. E. (1961) · doi:10.1515/9781400874668 · Cited by 2,802
Pattern Classification (2nd ed.)
Duda, R. O., Hart, P. E., & Stork, D. G. (1999) · Cited by 2,520
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 2×
“Many different feature sets have been proposed, including time domain coefficients (TD) [ 9 ], autoregressive coefficients (AR) [14], Cepstrum coefficients [15], short-time frequency transform, wavelet transform, wavelet packet transform [16] and concatenated TD and AR (TDAR) features [17].”
BackgroundSelf-citationA robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743 · cited 5×
“Estimates for the maximum allowable delay between the generation of MES and actuation of a prosthesis vary from 50ms[10]to400ms[11].Engleharthasshownthatlongeranalysis windows yield higher classification accuracies [ 12 ]; however, Farrell showed that controller delays longer than 100 ms reduce the usability of the pr…”
BackgroundMethodInfluentialSelf-citationMyoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089 · cited 4×
“This is similar to previous training data collection techniques which have investigated real-time pattern recognition control [ 32 ].”
BackgroundMethodResultInfluentialBellman, R. (1964) · IEEE Transactions on Circuit Theory · doi:10.1109/tct.1964.1082221 · Cited by 991
A wavelet-based continuous classification scheme for multifunction myoelectric control
Englehart, K., Hudgin, B., & Parker, P. A. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914793 · Cited by 697 · cited 2×
“Many different feature sets have been proposed, including time domain coefficients (TD) [9], autoregressive coefficients (AR) [14], Cepstrum coefficients [15], short-time frequency transform, wavelet transform, wavelet packet transform [ 16 ] and concatenated TD and AR (TDAR) features [17].”
BackgroundMethodSelf-citationMyoelectric signal processing for control of powered limb prostheses
Parker, P., Englehart, K., & Hudgins, B. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2006.08.006 · Cited by 651 · cited 1×
“Commercially available powered prostheses have historically been limited to one or two actuated degrees of freedom (DOFs) [ 1 ].”
BackgroundSelf-citationHuang, Y., Englehart, K. B., Hudgins, B., & Chan, A. D. C. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.856295 · Cited by 643 · cited 2×
“Most modern classification methods have been applied to MES control, including Bayesian classifiers [12], artificial neural networks, Gaussian mixture models [ 17 ], Hidden Markov Models [22], fuzzy logic [23], and genetic algorithms [24].”
BackgroundMethodSelf-citationA Comparison of Surface and Intramuscular Myoelectric Signal Classification
Hargrove, L. J., Englehart, K., & Hudgins, B. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889192 · Cited by 518 · cited 5×
“The purpose of the experiment was to compare the controllability of the proposed MBC system to another well researched pattern recognition system based on linear discriminant analysis (LDA) [7], [ 8 ], [12], [31], [32] and a conventional control scheme with mode switches [4].”
BackgroundMethodResultInfluentialSelf-citationThe optimal controller delay for myoelectric prostheses
Farrell, T. R., & Weir, R. F. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891391 · Cited by 438 · cited 1×
“Estimates for the maximum allowable delay between the generation of MES and actuation of a prosthesis vary from 50ms[10]to400ms[11].Engleharthasshownthatlongeranalysis windows yield higher classification accuracies [12]; however, Farrell showed that controller delays longer than 100 ms reduce the usability of the pros…”
BackgroundFuzzy EMG classification for prosthesis control
Chan, F. H. Y., Yang, Y.-S., Lam, F. K., Zhang, Y.-T., & Parker, P. A. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.867872 · Cited by 376 · cited 1×
“Most modern classification methods have been applied to MES control, including Bayesian classifiers [12], artificial neural networks, Gaussian mixture models [17], Hidden Markov Models [22], fuzzy logic [ 23 ], and genetic algorithms [24].”
MethodChu, J.-U., Moon, I., & Mun, M.-S. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.883695 · Cited by 352 · cited 1×
“Self organizing feature maps have also been used in series with PCA for unsupervised nonlinear dimensionality reduction [ 21 ].”
MethodContinuous Myoelectric Control for Powered Prostheses Using Hidden Markov Models
Chan, A. D. C., & Englehart, K. B. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.836492 · Cited by 343 · cited 1×
“Most modern classification methods have been applied to MES control, including Bayesian classifiers [12], artificial neural networks, Gaussian mixture models [17], Hidden Markov Models [ 22 ], fuzzy logic [23], and genetic algorithms [24].”
MethodSelf-citationDecoding a New Neural–Machine Interface for Control of Artificial Limbs
Zhou, P., Lowery, M. M., Englehart, K. B., Huang, H., Li, G., Hargrove, L., Dewald, J. P. A., & Kuiken, T. A. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00178.2007 · Cited by 215
Self-citationHargrove, L. J., Li, G., Englehart, K. B., & Hudgins, B. S. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2008171 · Cited by 211 · cited 1×
“Principal components analysis (PCA [16], [ 19 ]) and uncorrelated linear discriminant analysis (ULDA [20]) are examples of linear feature projection dimensionality reduction techniques that have been shown to reduce classification errors.”
MethodSelf-citationGraupe, D., Salahi, J., & Kohn, K. H. (1982) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(82)90021-8 · Cited by 205 · cited 1×
“Pattern recognition systems operate on the assumption that the set of features describing the myoelectric signal at a given electrode location will be repeatable for a given state of muscle activation and different between activation states [ 5 ].”
BackgroundUsing uncorrelated discriminant analysis for tissue classification with gene expression data
Ye, J., Li, T., Xiong, T., & Janardan, R. (2004) · IEEE/ACM Transactions on Computational Biology and Bioinformatics · doi:10.1109/tcbb.2004.45 · Cited by 183 · cited 3×
“reduction matriceswerecomputed usingthealgorithm provided by Ye [ 20 ] on data collection trials 1‐4.”
MethodInfluentialFarrell, T. R., & Weir, R. F. F. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.923917 · Cited by 159 · cited 2×
“MES has also been investigated as control input [ 7 ], [8]; investigators found that intramuscular MES yielded the same classification accuracy as surface MES for the motions studied.”
MethodResultREAL-TIME MYOELECTRIC CONTROL IN A VIRTUAL ENVIRONMENT TO RELATE USABILITY VS. ACCURACY
Lock, B. A., Englehart, K. B., & Hudgins, B. (2005) · DukeSpace (Duke University) · Cited by 122
Self-citationA three-state myo-electric control
Dorcas, D. S., & Scott, R. N. (1966) · Medical & Biological Engineering & Computing · doi:10.1007/bf02476154 · Cited by 119 · cited 1×
“Conventional control schemes have found widespread clinical use and usually map an estimate of the myoelectric signal (MES) amplitude [ 2 ], or rate of change [3], to one DOF of the prosthesis.”
BackgroundHefftner, G., Zucchini, W., & Jaros, G. G. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.1370 · Cited by 118
Walsh, N. E. (2006) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-200606000-00037 · Cited by 113
Graupe, D., Salahi, J., & Zhang, D. (1985) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(85)90004-4 · Cited by 97 · cited 1×
“Many different feature sets have been proposed, including time domain coefficients (TD) [9], autoregressive coefficients (AR) [ 14 ], Cepstrum coefficients [15], short-time frequency transform, wavelet transform, wavelet packet transform [16] and concatenated TD and AR (TDAR) features [17].”
BackgroundA Virtual Reality Environment for Designing and Fitting Neural Prosthetic Limbs
Hauschild, M., Davoodi, R., & Loeb, G. E. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891369 · Cited by 97 · cited 1×
“Consequently, functional tests of pattern recognition systems have only been completed in virtual reality environments [26]‐[ 28 ].”
BackgroundPractical Methods for Controlling Powered Upper-Extremity Prostheses
Williams, T. W. (1990) · Assistive Technology · doi:10.1080/10400435.1990.10132142 · Cited by 71
Hargrove, L., Zhou, P., Englehart, K., & Kuiken, T. A. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2010392 · Cited by 47 · cited 2×
“A weighted sum of all mean absolute values on the input channels were used to obtain a proportional control estimate [ 25 ].”
MethodSelf-citationApplying Genetic Programming To Control Of An Artificial Arm
Farry, K. A., Fernandez, J. J., Abramczyk, R., Novy, M., & Atkins, D. J. (1997) · DukeSpace (Duke University) · Cited by 23
A FLEXIBLE USER INTERFACE FOR RAPID PROTOTYPING OF ADVANCED REAL-TIME MYOELECTRIC CONTROL SCHEMES
Scheme, E., & Englehart, K. B. (2008) · DukeSpace (Duke University) · Cited by 23
Self-citation
Cited by
Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992
Myoelectric forearm prostheses: State of the art from a user-centered perspective
Peerdeman, B., Boere, D., Witteveen, H., Huis in `tVeld, R., Hermens, H., Stramigioli, S., Rietman, H., Veltink, P., & Misra, S. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.08.0161 · Cited by 469
Smith, L. H., Hargrove, L. J., Lock, B. A., & Kuiken, T. A. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2100828 · Cited by 443
Self-citationClassification of Simultaneous Movements Using Surface EMG Pattern Recognition
Young, A. J., Smith, L. H., Rouse, E. J., & Hargrove, L. J. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2232293 · Cited by 320
Self-citationYoung, A. J., Hargrove, L. J., & Kuiken, T. A. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2159216 · Cited by 287
Self-citation
Metadata
- Authors
- Hargrove, L. J., Scheme, E. J., Englehart, K. B., & Hudgins, B. S.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2010-02
- Volume
- 18
- Issue
- 1
- Pages
- 49-57
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2097823586
- Cited by
- 219
- References
- 31
- FWCI
- 10.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.