Experimental Analysis of Accuracy in the Identification of Motor Unit Spike Trains From High-Density Surface EMG
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
The aim of this study was to compare the decomposition results obtained from high-density surface electromyography (EMG) and concurrently recorded intramuscular EMG. Surface EMG signals were recorded with electrode grids from the tibialis anterior, biceps brachii, and abductor digiti minimi muscles of twelve healthy men during isometric contractions ranging between 5% and 20% of the maximal force. Bipolar intramuscular EMG signals were recorded with pairs of wire electrodes. Surface and intramuscular EMG were independently decomposed into motor unit spike trains. When averaged over all the contractions of the same contraction force, the percentage of discharge times of motor units identified by both decompositions varied in the ranges 84%-87% (tibialis anterior), 84%-86% (biceps brachii), and 87%-92% (abductor digiti minimi) across the force levels analyzed. This index of agreement between the two decompositions was linearly correlated with a self-consistency measure of motor unit discharge pattern that was based on coefficient of variation for the interspike interval (R(2) = 0.68 for tibialis anterior, R(2) = 0.56 for biceps brachii, and R(2) = 0.38 for abductor digiti minimi). These results constitute an important contribution to the validation of the noninvasive approach for the investigation of motor unit behavior in isometric low-force tasks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multichannel Blind Source Separation Using Convolution Kernel Compensation
Holobar, A., & Zazula, D. (2007) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2007.896108 · Cited by 648
Self-citationDecomposition of Surface EMG Signals
De Luca, C. J., Adam, A., Wotiz, R., Gilmore, L. D., & Nawab, S. H. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00009.2006 · Cited by 511
Analysis of motor units with high-density surface electromyography
Merletti, R., Holobar, A., & Farina, D. (2008) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2008.09.002 · Cited by 350
Self-citationEstimating motor unit discharge patterns from high-density surface electromyogram.
Holobar, A., Farina, D., Gazzoni, M., Merletti, R., & Zazula, D. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.10.160 · Cited by 318 · cited 3×
“We have also analyzed the performance of this method on experimental signals with concurrent recording of intramuscular signals but only on one representative recording [ 19 ].”
MethodResultInfluentialSelf-citationEMGLAB: An interactive EMG decomposition program
McGill, K. C., Lateva, Z. C., & Marateb, H. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.05.015 · Cited by 317
Lefever, R. S., & De Luca, C. J. (1982) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1982.324881 · Cited by 300
EMG signal decomposition: how can it be accomplished and used?
Stashuk, D. (2001) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00050-x · Cited by 268
Gazzoni, M., Farina, D., & Merletti, R. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.01.002 · Cited by 179
Self-citationA technique for the detection, decomposition and analysis of the EMG signal
Mambrito, B., & De Luca, C. J. (1984) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(84)90031-2 · Cited by 167
Correlation-based decomposition of surface electromyograms at low contraction forces
Holobar, A., & Zazula, D. (2004) · Medical & Biological Engineering & Computing · doi:10.1007/bf02350989 · Cited by 167
Self-citation
Cited by
Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992
Self-citationMulti-channel intramuscular and surface EMG decomposition by convolutive blind source separation
Negro, F., Muceli, S., Castronovo, A. M., Holobar, A., & Farina, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026027 · Cited by 647
Self-citationThe extraction of neural strategies from the surface EMG: an update
Farina, D., Merletti, R., & Enoka, R. M. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00162.2014 · Cited by 589
Self-citationHeckman, C. J., & Enoka, R. M. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c100087 · Cited by 414
Holobar, A., Minetto, M. A., & Farina, D. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/1/016008 · Cited by 400
“The proposed measure of decomposition accuracy is computationally bound to the CKC-based decomposition and high-density surface EMG recordings with several tens of recorded EMG channels (Holobar et al 2010).”
BackgroundMethodInfluentialSelf-citationDecoding the neural drive to muscles from the surface electromyogram
Farina, D., Holobar, A., Merletti, R., & Enoka, R. M. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.10.040 · Cited by 383
“For example, the range of individual motor units detected from the abductor digiti minimi, tibialis anterior, and biceps brachii muscles during static contractions at 610% MVC force was 1–19 (Holobar et al., 2010).”
BackgroundInfluentialSelf-citationTutorial: Analysis of motor unit discharge characteristics from high-density surface EMG signals
Del Vecchio, A., Holobar, A., Falla, D., Felici, F., Enoka, R. M., & Farina, D. (2020) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2020.102426 · Cited by 372
Self-citationProsthetic Myoelectric Control Strategies: A Clinical Perspective
Roche, A. D., Rehbaum, H., Farina, D., & Aszmann, O. C. (2014) · Current Surgery Reports · doi:10.1007/s40137-013-0044-8 · Cited by 261
Self-citationA Novel Framework Based on FastICA for High Density Surface EMG Decomposition
Chen, M., & Zhou, P. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2412038 · Cited by 260
Blind source identification from the multichannel surface electromyogram
Holobar, A., & Farina, D. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/7/r143 · Cited by 239
Self-citationCharacterization of Human Motor Units From Surface EMG Decomposition
Farina, D., & Holobar, A. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2498665 · Cited by 221
“Within this separation scheme, the convolution kernel compensation (CKC) approach [47], [48] has been the first convolutive BSS algorithm to be proposed and extensively tested for decomposition of multichannel EMG signals [50], [51].”
MethodSelf-citationPrinciples of Motor Unit Physiology Evolve With Advances in Technology
Farina, D., Negro, F., Muceli, S., & Enoka, R. M. (2016) · Physiology · doi:10.1152/physiol.00040.2015 · Cited by 212
“These methods are not impeded by the amount of overlap in the recorded action potentials (53-59) and have been proven to identify the discharge times of motor units with high accuracy in both multichannel intramuscular (93) and surface EMG recordings (58).”
BackgroundSelf-citationNeural Data-Driven Musculoskeletal Modeling for Personalized Neurorehabilitation Technologies
Sartori, M., Llyod, D. G., & Farina, D. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2538296 · Cited by 188
Self-citationHigh-density surface EMG maps from upper-arm and forearm muscles
Rojas-Martínez, M., Mañanas, M. A., & Alonso, J. F. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-85 · Cited by 181
“In recent years, on the other hand, the development and application of electrode arrays in one or two dimensions have allowed the study of the sEMG signal in the temporal and the spatial domain, opening new possibilities to the study of the neuromuscular system [5-7] and to the field of myoelectric control [8].”
BackgroundFunction and structure of the deep cervical extensor muscles in patients with neck pain
Schomacher, J., & Falla, D. (2013) · Manual Therapy · doi:10.1016/j.math.2013.05.009 · Cited by 160
Gallina, A., Disselhorst-Klug, C., Farina, D., Merletti, R., Besomi, M., Holobar, A., Enoka, R. M., Hug, F., Falla, D., Søgaard, K., et al. (2022) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2022.102656 · Cited by 77
Self-citationGallego, J. A., Dideriksen, J. L., Holobar, A., Ibanez, J., Glaser, V., Romero, J. P., Benito-Leon, J., Pons, J. L., Rocon, E., & Farina, D. (2015) · Journal of Neuroscience · doi:10.1523/jneurosci.0106-15.2015 · Cited by 67
“The convolution kernel compensation algorithm has been extensively validated in 500 healthy subjects performing different types of contractions (Holobar et al., 2009, 2010) and, in the particular case of tremor, through the analysis of simulated (Holobar et al., 2012) and experi- mental signals…”
MethodSelf-citationGallego, J. A., Dideriksen, J. L., Holobar, A., Ibáñez, J., Pons, J. L., Louis, E. D., Rocon, E., & Farina, D. (2015) · Journal of Neurophysiology · doi:10.1152/jn.00531.2014 · Cited by 64
“…has been validated with the decomposition of motor neuron activities in more than 15 muscles and 500 healthy subjects performing voluntary contractions (e.g., Holobar et al. 2009, 2010) and has recently been shown to work accurately also for EMG signals of tremor patients (Holobar et al. 2012).”
MethodSelf-citationYavuz, U. Ş., Negro, F., Sebik, O., Holobar, A., Frömmel, C., Türker, K. S., & Farina, D. (2015) · The Journal of Physiology · doi:10.1113/jp270635 · Cited by 55
“Moreover, there has been an extensive validation effort for surface EMG decomposition (Holobar et al. 2010, 2014; Nawab et al. 2010; Hu et al. 2013), so that the approach has recently begun to be accepted for drawing conclusions of physiological interest in healthy subjects (Beck et al. 2005; De…”
BackgroundMethodResultSelf-citation
Metadata
- Authors
- Holobar, A., Minetto, M. A., Botter, A., Negro, F., & Farina, D.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2010-06
- Volume
- 18
- Issue
- 3
- Pages
- 221-229
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2168149181
- Cited by
- 255
- References
- 19
- FWCI
- 4.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.