BCI Demographics II: How Many (and What Kinds of) People Can Use a High-Frequency SSVEP BCI?
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Brain-computer interface (BCI) systems use brain activity as an input signal and enable communication without movement. This study is a successor of our previous study (BCI demographics I) and examines correlations among BCI performance, personal preferences, and different subject factors such as age or gender for two sets of steady-state visual evoked potential (SSVEP) stimuli: one in the medium frequency range (13, 14, 15 and 16 Hz) and another in the high-frequency range (34, 36, 38, 40 Hz). High-frequency SSVEPs (above 30 Hz) diminish user fatigue and risk of photosensitive epileptic seizures. Results showed that most people, despite having no prior BCI experience, could use the SSVEP-based Bremen-BCI system in a very noisy field setting at a fair. Results showed that demographic parameters as well as handedness, tiredness, alcohol and caffeine consumption, etc., have no significant effect on the performance of SSVEP-based BCI. Most subjects did not consider the flickering stimuli annoying, only five out of total 86 participants indicated change in fatigue during the experiment. 84 subjects performed with a mean information transfer rate of 17.24 ±6.99 bit/min and an accuracy of 92.26 ±7.82% with the medium frequency set, whereas only 56 subjects performed with a mean information transfer rate of 12.10 ±7.31 bit/min and accuracy of 89.16 ±9.29% with the high-frequency set. These and other demographic analyses may help identify the best BCI for each user.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 1×
“The information transfer rate (ITR) was calculated based on the following formula [1]: (1) In this formula, represents the number of bits per trial, represents the total number of choices, and represents the probability of correct selection (accuracy).”
MethodBCI2000: A General-Purpose Brain-Computer Interface (BCI) System
Schalk, G., McFarland, D. J., Hinterberger, T., Birbaumer, N., & Wolpaw, J. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827072 · Cited by 3,024 · cited 1×
“The general-purpose software platform BCI2000 [39] was used for data acquisition, data storage and real-time data processing in a cycle of around 100 ms.”
MethodThe five percent electrode system for high-resolution EEG and ERP measurements
Oostenveld, R., & Praamstra, P. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00527-7 · Cited by 1,909 · cited 1×
“They were placed on for ground and as the input electrodes on the international system of EEG measurement [ 37 ].”
MethodSteady-state visually evoked potentials: Focus on essential paradigms and future perspectives
Vialatte, F.-B., Maurice, M., Dauwels, J., & Cichocki, A. (2010) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2009.11.005 · Cited by 1,066
Combining brain-computer interfaces and assistive technologies: state-of-the-art and challenges
Millán, J. D. R. (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00161 · Cited by 866 · cited 1×
“Nowadays, the most commonly used EEG-based BCI systems employ event-related synchronization of mu and beta bands, event-related potentials and steady-state visual evoked potential (SSVEP) [7], [8].”
MethodAn efficient P300-based brain–computer interface for disabled subjects
Hoffmann, U., Vesin, J.-M., Ebrahimi, T., & Diserens, K. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.03.005 · Cited by 859
The e-puck, a Robot Designed for Education in Engineering
Francesco Mondada, C., Michael Bonani, C., Raemy, X., Pugh, J., Cianci, C. M., Klaptocz, A., Magnenat, S., Zufferey, J., Floreano, D., & Martinoli, A. (2009) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · Cited by 785
Bin, G., Gao, X., Yan, Z., Hong, B., & Gao, S. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/046002 · Cited by 773 · cited 2×
“Spelling or dialing applications [19] re-sults in higher ITR values, because there is no break between two commands caused by the processing time of the application.”
BackgroundInfluentialNeurophysiological predictor of SMR-based BCI performance
Blankertz, B., Sannelli, C., Halder, S., Hammer, E. M., Kübler, A., Müller, K.-R., Curio, G., & Dickhaus, T. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.022 · Cited by 674 · cited 1×
“New articles have begun to address BCI illiteracy by the determination of neurophysiological factors that may serve to predict BCI performance [34] or by learning about individual differences and personal preferences using questionnaires [11], [35].”
BackgroundA Survey of Stimulation Methods Used in SSVEP-Based BCIs
Zhu, D., Bieger, J., Garcia Molina, G., & Aarts, R. M. (2010) · Computational Intelligence and Neuroscience · doi:10.1155/2010/702357 · Cited by 654
How many people are able to control a P300-based brain-computer interface (BCI)?
Guger, C., Daban, S., Sellers, E., Holzner, C., Krausz, G., Carabalona, R., Gramatica, F., & Edlinger, G. (2009) · Neuroscience Letters · doi:10.1016/j.neulet.2009.06.045 · Cited by 652 · cited 2×
“With a P300-based BCI, 93% of 99 subjects reached an accuracy of over 60% [32] and less than 3% of 100 subjects achieved an accuracy of 0% [33].”
MethodA BCI-based environmental controller for the motion-disabled
Gao, X., Xu, D., Cheng, M., & Gao, S. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814449 · Cited by 637 · cited 1×
“This measure depends on three factors: speed, accuracy, and number of targets, which can vary from two [13] up to 48 [14].”
BackgroundMultiple Channel Detection of Steady-State Visual Evoked Potentials for Brain-Computer Interfaces
Friman, O., Volosyak, I., & Graser, A. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889160 · Cited by 541 · cited 1×
“In sum-mary, we use the Minimum Energy Combination [40] for spatial filtering of the electrode data and calculate the power in each stimulus frequency based on a 2 s data window.”
MethodSelf-citationHow many people are able to operate an EEG-based brain-computer interface (BCI)?
Guger, C., Edlinger, G., Harkam, W., Niedermayer, I., & Pfurtscheller, G. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814481 · Cited by 526 · cited 2×
“With a P300-based BCI, 93% of 99 subjects reached an accuracy of over 60% [32] and less than 3% of 100 subjects achieved an accuracy of 0% [33].”
Clinical Applications of Brain-Computer Interfaces: Current State and Future Prospects
Mak, J. N., & Wolpaw, J. R. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2035356 · Cited by 509 · cited 1×
“Nowadays, the most commonly used EEG-based BCI systems employ event-related synchronization of mu and beta bands, event-related potentials and steady-state visual evoked potential (SSVEP) [7], [8].”
MethodTowards a cure for BCI illiteracy
Vidaurre, C., & Blankertz, B. (2010) · Brain Topography · doi:10.1007/s10548-009-0121-6 · Cited by 501 · cited 1×
“Another important topic in BCI research is inter-subject variability that often leads to the well-documented “BCI illiteracy” phenomenon [30], i.e., a non-negligible portion of subjects are unable to attain effective control [ 31 ].”
BackgroundPhotic‐ and Pattern‐induced Seizures: A Review for the Epilepsy Foundation of America Working Group
Fisher, R. S., Harding, G., Erba, G., Barkley, G. L., & Wilkins, A. (2005) · Epilepsia · doi:10.1111/j.1528-1167.2005.31405.x · Cited by 427 · cited 1×
“Stimulation in this frequency range evokes SSVEPs with a large amplitude but is annoying and tiring for the user or can even induce epileptic seizures for photosensitive subjects [24].”
BackgroundBrain-Computer Interfaces Based on Visual Evoked Potentials
Wang, Y., Gao, X., Hong, B., Jia, C., & Gao, S. (2008) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2008.923958 · Cited by 423 · cited 1×
“The SSVEP approach currently provides the fastest and the most reliable communication paradigm for the implementation of a noninvasive BCI system [15]–[18].”
BackgroundSteady-State VEP-Based Brain-Computer Interface Control in an Immersive 3D Gaming Environment
Lalor, E. C., Kelly, S. P., Finucane, C., Burke, R., Smith, R., Reilly, R. B., & McDarby, G. (2005) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/asp.2005.3156 · Cited by 421
EEG-based communication: improved accuracy by response verification
Wolpaw, J. R., Ramoser, H., McFarland, D. J., & Pfurtscheller, G. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.712231 · Cited by 396 · cited 1×
“The performance of the BCI can be assessed by the information transfer rate (ITR) as introduced in [ 9 ] and reported in the majority of BCI studies [10]–[12].”
MethodBCI demographics: how many (and what kinds of) people can use an SSVEP BCI?
Allison, B., Luth, T., Valbuena, D., Teymourian, A., Volosyak, I., & Graser, A. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039495 · Cited by 344 · cited 4×
“New articles have begun to address BCI illiteracy by the determination of neurophysiological factors that may serve to predict BCI performance [34] or by learning about individual differences and personal preferences using questionnaires [ 11 ], [35].”
MethodResultInfluentialSelf-citationHuman Cerebral Activation during Steady-State Visual-Evoked Responses
Pastor, M. A., Artieda, J., Arbizu, J., Valencia, M., & Masdeu, J. C. (2003) · The Journal of Neuroscience · doi:10.1523/jneurosci.23-37-11621.2003 · Cited by 324 · cited 2×
“However, the amplitude of SSVEPs strongly decreases at high frequencies [25], there are only a few papers that have reported the successful implementation of high-frequency SSVEP BCIs up to now [26]–[29].”
BackgroundInfluentialKübler, A., Furdea, A., Halder, S., Hammer, E. M., Nijboer, F., & Kotchoubey, B. (2009) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2008.04122.x · Cited by 303 · cited 1×
“These devices use brain activity as an input signal and may be the only possible way of communication for severely disabled users, such as persons suffering from Cerebral Palsy, stroke victims, or persons with injuries of the brain or spinal cord [ 3 ], [4].”
BackgroundA Comprehensive Survey of Brain Interface Technology Designs
Mason, S. G., Bashashati, A., Fatourechi, M., Navarro, K. F., & Birch, G. E. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9170-0 · Cited by 299 · cited 1×
“its high time resolution, ease of acquisition, and lower system costs as compared to other brain activity monitoring modalities [6].”
BackgroundBrain-Computer Interfacing for Intelligent Systems
Nijholt, A., & Tan, D. (2008) · IEEE Intelligent Systems · doi:10.1109/mis.2008.41 · Cited by 279 · cited 1×
“Another important topic in BCI research is inter-subject variability that often leads to the well-documented “BCI illiteracy” phenomenon [30], i.e., a non-negligible portion of subjects are unable to attain effective control [31].”
BackgroundTrejo, L. J., Rosipal, R., & Matthews, B. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875578 · Cited by 267 · cited 1×
“Other studies have reported classification accuracies of more than 90% [21]–[23].”
BackgroundVEP-based brain-computer interfaces: time, frequency, and code modulations [Research Frontier
Bin, G., Gao, X., Wang, Y., Hong, B., & Gao, S. (2009) · IEEE Computational Intelligence Magazine · doi:10.1109/mci.2009.934562 · Cited by 256 · cited 1×
“In another paper from the same research group, Bin et al., reported ITR values of bit/min for code based modulation [ 20 ].”
BackgroundAn SSVEP-Actuated Brain Computer Interface Using Phase-Tagged Flickering Sequences: A Cursor System
Lee, P., Sie, J.-J., Liu, Y.-J., Wu, C.-H., Lee, M.-H., Shu, C.-H., Li, P.-H., Sun, C., & Shyu, K. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-9964-y · Cited by 144 · cited 1×
“However, the amplitude of SSVEPs strongly decreases at high frequencies [25], there are only a few papers that have reported the successful implementation of high-frequency SSVEP BCIs up to now [26]–[ 29 ].”
BackgroundParini, S., Maggi, L., Turconi, A. C., & Andreoni, G. (2009) · Computational Intelligence and Neuroscience · doi:10.1155/2009/864564 · Cited by 126 · cited 1×
“The performance of the BCI can be assessed by the information transfer rate (ITR) as introduced in [9] and reported in the majority of BCI studies [10]–[12].”
MethodBrain–computer interface using water-based electrodes
Volosyak, I., Valbuena, D., Malechka, T., Peuscher, J., & Gräser, A. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/6/066007 · Cited by 82 · cited 1×
“Our recent study presents the first results of the evaluation of water-based electrodes in the online BCI experiments with ten healthy subjects [42].”
BackgroundSelf-citationEvaluation of the Bremen SSVEP based BCI in real world conditions
Volosyak, I., Cecotti, H., Valbuena, D., & Graser, A. (2009) · 2009 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2009.5209543 · Cited by 74 · cited 4×
“Additionally, after classification of a nonzero class, the data window was cleared [23] and an idle period, in which no further classification will be made, of 1 s is introduced.”
BackgroundMethodInfluentialSelf-citationAn SSVEP-Based Brain–Computer Interface for the Control of Functional Electrical Stimulation
Gollee, H., Volosyak, I., McLachlan, A. J., Hunt, K. J., & Gräser, A. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2043432 · Cited by 74 · cited 1×
“The performance of the BCI can be assessed by the information transfer rate (ITR) as introduced in [9] and reported in the majority of BCI studies [10]–[ 12 ].”
MethodSelf-citationImpact of Frequency Selection on LCD Screens for SSVEP Based Brain-Computer Interfaces
Volosyak, I., Cecotti, H., & Gräser, A. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-02478-8_88 · Cited by 57 · cited 1×
“New articles have begun to address BCI illiteracy by the determination of neurophysiological factors that may serve to predict BCI performance [34] or by learning about individual differences and personal preferences using questionnaires [11], [35].”
BackgroundSelf-citationEEG based BCI-towards a better control. Brain-computer interface research at aalborg university
Nielsen, K. D., Cabrera, A. F., & do Nascimento, O. F. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875529 · Cited by 48
Steady-State Visual Evoked Potential Response - Impact of the Time Segment Length
Volosyak, I., Cecotti, H., & Gräser, A. (2010) · Control and Intelligent Systems · doi:10.2316/j.2010.216.680-0145 · Cited by 25 · cited 2×
“Due to further modifications in the SSVEP signal processing algorithm [23], [41], the number of BCI illiterates was reduced to 2.33% using medium ranged frequencies in this work without decreasing the mean accuracy.”
BackgroundMethodInfluentialSelf-citationDetection of high frequency steady state visual evoked potentials for Brain-computer interfaces
Garcia‐Molina, G., Ibañez, D. P., Mihajlović, V., & Chestakov, D. A. (2009) · Cited by 21
Hoffmann, U., Fimbel, E. J., & Keller, T. (2009) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2009.5109334 · Cited by 16
Sensor Modalities for Brain-Computer Interfacing
Schalk, G. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-02577-8_67 · Cited by 14 · cited 1×
“2121919 an increased interest in noninvasive BCI systems which are based on various sensory modalities [5].”
Background
Cited by
A comprehensive review of EEG-based brain–computer interface paradigms
Abiri, R., Borhani, S., Sellers, E. W., Jiang, Y., & Zhao, X. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaf12e · Cited by 946
A high-ITR SSVEP-based BCI speller
Chen, X., Chen, Z., Gao, S., & Gao, X. (2014) · Brain-Computer Interfaces · doi:10.1080/2326263x.2014.944469 · Cited by 301
Trends in EEG-BCI for daily-life: Requirements for artifact removal
Minguillon, J., Lopez-Gordo, M. A., & Pelayo, F. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.09.005 · Cited by 289
Cao, T., Wan, F., Wong, C. M., da Cruz, J. N., & Hu, Y. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-28 · Cited by 188
Comparing user-dependent and user-independent training of CNN for SSVEP BCI
Ravi, A., Beni, N. H., Manuel, J., & Jiang, N. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab6a67 · Cited by 165
“This method is particularly suited for SSVEP BCIs as these responses are more consistent across most humans, compared with other signal modalities of BCI such as sensory-motor rhythm [11].”
Method
Metadata
- Authors
- Volosyak, I., Valbuena, D., Luth, T., Malechka, T., & Graser, A.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2011-06
- Volume
- 19
- Issue
- 3
- Pages
- 232-239
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2159314878
- Cited by
- 175
- References
- 38
- FWCI
- 3.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.