Limb-State Information Encoded by Peripheral and Central Somatosensory Neurons: Implications for an Afferent Interface
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
A major issue to be addressed in the development of neural interfaces for prosthetic control is the need for somatosensory feedback. Here, we investigate two possible strategies: electrical stimulation of either dorsal root ganglia (DRG) or primary somatosensory cortex (S1). In each approach, we must determine a model that reflects the representation of limb state in terms of neural discharge. This model can then be used to design stimuli that artificially activate the nervous system to convey information about limb state to the subject. Electrically activating DRG neurons using naturalistic stimulus patterns, modeled on recordings made during passive limb movement, evoked activity in S1 that was similar to that of the original movement. We also found that S1 neural populations could accurately discriminate different patterns of DRG stimulation across a wide range of stimulus pulse-rates. In studying the neural coding in S1, we also decoded the kinematics of active limb movement using multi-electrode recordings in the monkey. Neurons having both proprioceptive and cutaneous receptive fields contributed equally to this decoding. Some neurons were most informative of limb state in the recent past, but many others appeared to signal upcoming movements suggesting that they also were modulated by an efference copy signal. Finally, we show that a monkey was able to detect stimulation through a large percentage of electrodes implanted in area 2. We discuss the design of appropriate stimulus paradigms for conveying time-varying limb state information, and the relative merits and limitations of central and peripheral approaches.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 1×
“The importance of somatosensory feedback prompts the need for an afferent interface to parallel the efferent interfaces that have been under development for over a decade [3–8].”
BackgroundLearning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761 · cited 1×
“The importance of somatosensory feedback prompts the need for an afferent interface to parallel the efferent interfaces that have been under development for over a decade [3–8].”
BackgroundCortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
Cortical microstimulation influences perceptual judgements of motion direction
Salzman, C. D., Britten, K. H., & Newsome, W. T. (1990) · Nature · doi:10.1038/346174a0 · Cited by 881 · cited 1×
“In those experiments, monkeys were trained to distinguish the mean direction of motion of a partially coherent random dot display [63–65].”
MethodA high-performance brain–computer interface
Santhanam, G., Ryu, S. I., Yu, B. M., Afshar, A., & Shenoy, K. V. (2006) · Nature · doi:10.1038/nature04968 · Cited by 698
Schmidt, E. M., Bak, M. J., Hambrecht, F. T., Kufta, C. V., O'Rourke, D. K., & Vallabhanath, P. (1996) · Brain · doi:10.1093/brain/119.2.507 · Cited by 672 · cited 1×
“able to detect small spots of light (phosphenes) of differing size, color, and location [15].”
BackgroundControl of limb dynamics in normal subjects and patients without proprioception
Sainburg, R. L., Ghilardi, M. F., Poizner, H., & Ghez, C. (1995) · Journal of Neurophysiology · doi:10.1152/jn.1995.73.2.820 · Cited by 662 · cited 1×
“servation is consistent with the fact that patients lacking proprioceptive feedback due to large-fiber neuropathy and other causes suffer from greatly impoverished movement quality, despite having normal muscle strength [2].”
ResultHisted, M. H., Bonin, V., & Reid, R. C. (2009) · Neuron · doi:10.1016/j.neuron.2009.07.016 · Cited by 604 · cited 1×
“However, there is recent evidence suggesting that electrical stimulation activates neurons more sparsely and at a greater distance from the electrode tip than previously thought [56].”
BackgroundOchoa, J., & Torebjörk, E. (1983) · The Journal of Physiology · doi:10.1113/jphysiol.1983.sp014873 · Cited by 467 · cited 2×
“The basic feasibility has already been demonstrated in a limited number of human studies [9–13].”
Background
Cited by
Restoring sensorimotor function through intracortical interfaces: progress and looming challenges
Bensmaia, S. J., & Miller, L. E. (2014) · Nature Reviews Neuroscience · doi:10.1038/nrn3724 · Cited by 368
Self-citationNeural interfaces for somatosensory feedback: bringing life to a prosthesis
Tyler, D. J. (2015) · Current Opinion in Neurology · doi:10.1097/wco.0000000000000266 · Cited by 105
“Preclinical work in brain [78], dorsal root ganglion [79,80] and intraspinal microstimulation [81] approaches are progressing, but peripheral interfaces have achieved chronic clinical demonstration [82 && ,83 & ].”
BackgroundInterfacing the Somatosensory System to Restore Touch and Proprioception: Essential Considerations
Weber, D. J., Friesen, R., & Miller, L. E. (2012) · Journal of Motor Behavior · doi:10.1080/00222895.2012.735283 · Cited by 98
“This approach has been used in cats to compare the S1 neural response to natural inputs (e.g., leg motion) to that of electrical stimulation applied through an array of microelectrodes in the dorsal root ganglia (DRG; Weber et al., 2011).”
BackgroundMethodSelf-citationSelectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review.
Ghafoor, U., Kim, S., & Hong, K.-S. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00059 · Cited by 88
“Preclinical works on the approaches related to the brain (Bensmaia and Miller, 2014), dorsal root ganglion (Weber et al., 2006, 2011; Bruns et al., 2013), and intra-spinal microstimulation (Gaunt et al., 2006; Capogrosso et al., 2016) are progressing.”
Hiremath, S. V., Chen, W., Wang, W., Foldes, S., Yang, Y., Tyler-Kabara, E. C., Collinger, J. L., & Boninger, M. L. (2015) · Frontiers in Integrative Neuroscience · doi:10.3389/fnint.2015.00040 · Cited by 53
“…to perform sensory discrimination tasks or even closed-loop brain-control tasks successfully (Romo et al., 2000; Horch et al., 2011; Miller and Weber, 2011; O’Doherty et al., 2011; Weber et al., 2011, 2012; Johnson et al., 2013; Tabot et al., 2013; Zaaimi et al., 2013; Bensmaia and Miller, 2014).”
Background
Metadata
- Authors
- Weber, D. J., London, B. M., Hokanson, J. A., Ayers, C. A., Gaunt, R. A., Torres, R. R., Zaaimi, B., & Miller, L. E.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2011-10
- Volume
- 19
- Issue
- 5
- Pages
- 501-513
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2111268077
- Cited by
- 100
- References
- 15
- FWCI
- 4.17
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Limb-State Information Encoded by Peripheral and Central Somatosensory Neurons: Implications for an Afferent Interface. https://app.cochat.ai/papers/10.1109/tnsre.2011.2163145
- The paper
- Weber, D. J., London, B. M., Hokanson, J. A., Ayers, C. A., Gaunt, R. A., Torres, R. R., Zaaimi, B., & Miller, L. E. (2011). Limb-State Information Encoded by Peripheral and Central Somatosensory Neurons: Implications for an Afferent Interface. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2011.2163145
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.