Design and Validation of a Fully Implantable, Chronic, Closed-Loop Neuromodulation Device With Concurrent Sensing and Stimulation
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Chronically implantable, closed-loop neuromodulation devices with concurrent sensing and stimulation hold promise for better understanding the nervous system and improving therapies for neurological disease. Concurrent sensing and stimulation are needed to maximize usable neural data, minimize time delays for closed-loop actuation, and investigate the instantaneous response to stimulation. Current systems lack concurrent sensing and stimulation primarily because of stimulation interference to neural signals of interest. While careful design of high performance amplifiers has proved useful to reduce disturbances in the system, stimulation continues to contaminate neural sensing due to biological effects like tissue-electrode impedance mismatch and constraints on stimulation parameters needed to deliver therapy. In this work we describe systematic methods to mitigate the effect of stimulation through a combination of sensing hardware, stimulation parameter selection, and classification algorithms that counter residual stimulation disturbances. To validate these methods we implemented and tested a completely implantable system for over one year in a large animal model of epilepsy. The system proved capable of measuring and detecting seizure activity in the hippocampus both during and after stimulation. Furthermore, we demonstrate an embedded algorithm that actuates neural modulation in response to seizure detection during stimulation, validating the capability to detect bioelectrical markers in the presence of therapy and titrate it appropriately. The capability to detect neural states in the presence of stimulation and optimally titrate therapy is a key innovation required for generalizing closed-loop neural systems for multiple disease states.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kuhn, A. A., Kempf, F., Brucke, C., Gaynor Doyle, L., Martinez-Torres, I., Pogosyan, A., Trottenberg, T., Kupsch, A., Schneider, G.-H., Hariz, M. I., et al. (2008) · Journal of Neuroscience · doi:10.1523/jneurosci.0282-08.2008 · Cited by 858
Weinberger, M., Mahant, N., Hutchison, W. D., Lozano, A. M., Moro, E., Hodaie, M., Lang, A. E., & Dostrovsky, J. O. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00697.2006 · Cited by 588
Denison, T., Consoer, K., Santa, W., Avestruz, A.-T., Cooley, J., & Kelly, A. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.908664 · Cited by 451
Self-citationLong-term motor cortex plasticity induced by an electronic neural implant
Jackson, A., Mavoori, J., & Fetz, E. E. (2006) · Nature · doi:10.1038/nature05226 · Cited by 450
Deep Brain Stimulation in Patients with Refractory Temporal Lobe Epilepsy
Boon, P., Vonck, K., De Herdt, V., Van Dycke, A., Goethals, M., Goossens, L., Van Zandijcke, M., De Smedt, T., Dewaele, I., Achten, R., et al. (2007) · Epilepsia · doi:10.1111/j.1528-1167.2007.01005.x · Cited by 368
Velasco, A. L., Velasco, F., Velasco, M., Trejo, D., Castro, G., & Carrillo‐Ruiz, J. D. (2007) · Epilepsia · doi:10.1111/j.1528-1167.2007.01181.x · Cited by 331
Osorio, I., Frei, M. G., & Wilkinson, S. B. (1998) · Epilepsia · doi:10.1111/j.1528-1157.1998.tb01430.x · Cited by 318
Intra-operative STN DBS attenuates the prominent beta rhythm in the STN in Parkinson's disease
Wingeier, B., Tcheng, T., Koop, M. M., Hill, B. C., Heit, G., & Bronte-Stewart, H. M. (2006) · Experimental Neurology · doi:10.1016/j.expneurol.2005.09.016 · Cited by 287
Hippocampal electrical stimulation in mesial temporal lobe epilepsy
Tellez-Zenteno, J. F., McLachlan, R. S., Parrent, A., Kubu, C. S., & Wiebe, S. (2006) · Neurology · doi:10.1212/01.wnl.0000209300.49308.8f · Cited by 246
Technology Insight: neuroengineering and epilepsy—designing devices for seizure control
Stacey, W. C., & Litt, B. (2008) · Nature Clinical Practice Neurology · doi:10.1038/ncpneuro0750 · Cited by 234
Azin, M., Guggenmos, D. J., Barbay, S., Nudo, R. J., & Mohseni, P. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2108770 · Cited by 164
A chronic generalized bi-directional brain–machine interface
Rouse, A. G., Stanslaski, S. R., Cong, P., Jensen, R. M., Afshar, P., Ullestad, D., Gupta, R., Molnar, G. F., Moran, D. W., & Denison, T. J. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036018 · Cited by 155
Self-citationDeep Brain Stimulation for Epilepsy
Halpern, C. H., Samadani, U., Litt, B., Jaggi, J. L., & Baltuch, G. H. (2008) · Neurotherapeutics · doi:10.1016/j.nurt.2007.10.065 · Cited by 151
A 5 $\mu$W/Channel Spectral Analysis IC for Chronic Bidirectional Brain–Machine Interfaces
Avestruz, A.-T., Santa, W., Carlson, D., Jensen, R., Stanslaski, S., Helfenstine, A., & Denison, T. (2008) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2006460 · Cited by 143
Self-citationRossi, L., Foffani, G., Marceglia, S., Bracchi, F., Barbieri, S., & Priori, A. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/010 · Cited by 131
An autonomous implantable computer for neural recording and stimulation in unrestrained primates
Mavoori, J., Jackson, A., Diorio, C., & Fetz, E. E. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.04.017 · Cited by 122
Rossi, L., Marceglia, S. R. F., Foffani, G., Cogiamanian, F. M., Tamma, F., Rampini, P. M., Barbieri, S., Bracchi, F., & Priori, A. (2008) · Brain Research Bulletin · doi:10.1016/j.brainresbull.2008.01.023 · Cited by 104
A system for neural recording and closed-loop intracortical microstimulation in awake rodents.
Venkatraman, S., Elkabany, K., Long, J. D., Yao, Y., & Carmena, J. M. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2005944 · Cited by 96
Ince, N. F., GUPTE, A. A., Wichmann, T., Ashe, J., Henry, T. R., Bebler, M., Eberly, L. E., & Abosch, A. (2010) · Neurosurgery · doi:10.1227/01.neu.0000372091.64824.63 · Cited by 93
Yoshida, F., Martínez‐Torres, I., Pogosyan, A. H., Holl, E. M., Petersen, E., Chen, C. C., Foltynie, T., Limousin, P. D., Zrinzo, L. U., Hariz, M. I., et al. (2010) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.2009.190918 · Cited by 83
Loukas, C., & Brown, P. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.02.017 · Cited by 67
Shoeb, A. H., Carlson, D., Panken, E., & Denison, T. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333790 · Cited by 62
Self-citationA Miniaturized System for Spike-Triggered Intracortical Microstimulation in an Ambulatory Rat
Azin, M., Guggenmos, D. J., Barbay, S., Nudo, R. J., & Mohseni, P. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2159603 · Cited by 46
An implantable Bi-directional brain-machine interface system for chronic neuroprosthesis research
Stanslaski, S. R., Cong, P., Carlson, D., Santa, W. A., Jensen, R. M., Molnar, G., Marks, W. J., Shafquat, A., & Denison, T. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5334562 · Cited by 43
Self-citationAl-ani, T., Cazettes, F., Palfi, S., & Lefaucheur, J. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2011.03.022 · Cited by 42
Sensory feedback for upper limb prostheses
Hsiao, S. S., Fettiplace, M. R., & Darbandi, B. (2011) · Progress in brain research · doi:10.1016/b978-0-444-53355-5.00005-1 · Cited by 34
Harding, G. W. (1991) · Computers and Biomedical Research · doi:10.1016/0010-4809(91)90029-v · Cited by 31
Of seizure prediction, statistics, and dogs
Litt, B., & Krieger, A. Μ. (2007) · Neurology · doi:10.1212/01.wnl.0000255912.43452.12 · Cited by 23
Advancing neuromodulation using a dynamic control framework
Afshar, P., Wei, X., Lazarewicz, M. T., Gupta, R., Molnar, G., & Denison, T. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090150 · Cited by 2
Self-citation
Cited by
Piech, D. K., Johnson, B. C., Shen, K., Ghanbari, M. M., Li, K. Y., Neely, R. M., Kay, J. E., Carmena, J. M., Maharbiz, M. M., & Muller, R. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0518-9 · Cited by 442
The modulatory effect of adaptive deep brain stimulation on beta bursts in Parkinson’s disease
Tinkhauser, G., Pogosyan, A., Little, S., Beudel, M., Herz, D. M., Tan, H., & Brown, P. (2017) · Brain · doi:10.1093/brain/awx010 · Cited by 454
Implantable devices: issues and challenges
Bazaka, K., & Jacob, M. (2012) · Electronics · doi:10.3390/electronics2010001 · Cited by 358
“correlates with disease symptoms, and can therefore be used as a biomarker [50].”
InfluentialCasson, A. J. (2019) · Biomedical Engineering Letters · doi:10.1007/s13534-018-00093-6 · Cited by 340
Adaptive deep brain stimulation (aDBS) controlled by local field potential oscillations
Priori, A., Foffani, G., Rossi, L., & Marceglia, S. (2013) · Experimental Neurology · doi:10.1016/j.expneurol.2012.09.013 · Cited by 331
Metadata
- Authors
- Stanslaski, S., Afshar, P., Cong, P., Giftakis, J., Stypulkowski, P., Carlson, D., Linde, D., Ullestad, D., Avestruz, A.-T., & Denison, T.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2012-07
- Volume
- 20
- Issue
- 4
- Pages
- 410-421
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2060583550
- Cited by
- 330
- References
- 29
- FWCI
- 5.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.