Design and Validation of a Fully Implantable, Chronic, Closed-Loop Neuromodulation Device With Concurrent Sensing and Stimulation
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Chronically implantable, closed-loop neuromodulation devices with concurrent sensing and stimulation hold promise for better understanding the nervous system and improving therapies for neurological disease. Concurrent sensing and stimulation are needed to maximize usable neural data, minimize time delays for closed-loop actuation, and investigate the instantaneous response to stimulation. Current systems lack concurrent sensing and stimulation primarily because of stimulation interference to neural signals of interest. While careful design of high performance amplifiers has proved useful to reduce disturbances in the system, stimulation continues to contaminate neural sensing due to biological effects like tissue-electrode impedance mismatch and constraints on stimulation parameters needed to deliver therapy. In this work we describe systematic methods to mitigate the effect of stimulation through a combination of sensing hardware, stimulation parameter selection, and classification algorithms that counter residual stimulation disturbances. To validate these methods we implemented and tested a completely implantable system for over one year in a large animal model of epilepsy. The system proved capable of measuring and detecting seizure activity in the hippocampus both during and after stimulation. Furthermore, we demonstrate an embedded algorithm that actuates neural modulation in response to seizure detection during stimulation, validating the capability to detect bioelectrical markers in the presence of therapy and titrate it appropriately. The capability to detect neural states in the presence of stimulation and optimally titrate therapy is a key innovation required for generalizing closed-loop neural systems for multiple disease states.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kuhn, A. A., Kempf, F., Brucke, C., Gaynor Doyle, L., Martinez-Torres, I., Pogosyan, A., Trottenberg, T., Kupsch, A., Schneider, G.-H., Hariz, M. I., et al. (2008) · Journal of Neuroscience · doi:10.1523/jneurosci.0282-08.2008 · Cited by 858
Weinberger, M., Mahant, N., Hutchison, W. D., Lozano, A. M., Moro, E., Hodaie, M., Lang, A. E., & Dostrovsky, J. O. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00697.2006 · Cited by 588
Denison, T., Consoer, K., Santa, W., Avestruz, A.-T., Cooley, J., & Kelly, A. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.908664 · Cited by 451
Self-citationLong-term motor cortex plasticity induced by an electronic neural implant
Jackson, A., Mavoori, J., & Fetz, E. E. (2006) · Nature · doi:10.1038/nature05226 · Cited by 450
Deep Brain Stimulation in Patients with Refractory Temporal Lobe Epilepsy
Boon, P., Vonck, K., De Herdt, V., Van Dycke, A., Goethals, M., Goossens, L., Van Zandijcke, M., De Smedt, T., Dewaele, I., Achten, R., et al. (2007) · Epilepsia · doi:10.1111/j.1528-1167.2007.01005.x · Cited by 368
Velasco, A. L., Velasco, F., Velasco, M., Trejo, D., Castro, G., & Carrillo‐Ruiz, J. D. (2007) · Epilepsia · doi:10.1111/j.1528-1167.2007.01181.x · Cited by 331
Osorio, I., Frei, M. G., & Wilkinson, S. B. (1998) · Epilepsia · doi:10.1111/j.1528-1157.1998.tb01430.x · Cited by 318
Intra-operative STN DBS attenuates the prominent beta rhythm in the STN in Parkinson's disease
Wingeier, B., Tcheng, T., Koop, M. M., Hill, B. C., Heit, G., & Bronte-Stewart, H. M. (2006) · Experimental Neurology · doi:10.1016/j.expneurol.2005.09.016 · Cited by 287
Hippocampal electrical stimulation in mesial temporal lobe epilepsy
Tellez-Zenteno, J. F., McLachlan, R. S., Parrent, A., Kubu, C. S., & Wiebe, S. (2006) · Neurology · doi:10.1212/01.wnl.0000209300.49308.8f · Cited by 246
Technology Insight: neuroengineering and epilepsy—designing devices for seizure control
Stacey, W. C., & Litt, B. (2008) · Nature Clinical Practice Neurology · doi:10.1038/ncpneuro0750 · Cited by 234
Cited by
The modulatory effect of adaptive deep brain stimulation on beta bursts in Parkinson’s disease
Tinkhauser, G., Pogosyan, A., Little, S., Beudel, M., Herz, D. M., Tan, H., & Brown, P. (2017) · Brain · doi:10.1093/brain/awx010 · Cited by 454
Piech, D. K., Johnson, B. C., Shen, K., Ghanbari, M. M., Li, K. Y., Neely, R. M., Kay, J. E., Carmena, J. M., Maharbiz, M. M., & Muller, R. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0518-9 · Cited by 442
Implantable devices: issues and challenges
Bazaka, K., & Jacob, M. (2012) · Electronics · doi:10.3390/electronics2010001 · Cited by 358
“correlates with disease symptoms, and can therefore be used as a biomarker [50].”
InfluentialCasson, A. J. (2019) · Biomedical Engineering Letters · doi:10.1007/s13534-018-00093-6 · Cited by 340
Adaptive deep brain stimulation (aDBS) controlled by local field potential oscillations
Priori, A., Foffani, G., Rossi, L., & Marceglia, S. (2013) · Experimental Neurology · doi:10.1016/j.expneurol.2012.09.013 · Cited by 331
Closed-loop Neurostimulation: The Clinical Experience
Sun, F. T., & Morrell, M. J. (2014) · Neurotherapeutics · doi:10.1007/s13311-014-0280-3 · Cited by 286
Cingulate dynamics track depression recovery with deep brain stimulation
Alagapan, S., Choi, K. S., Heisig, S., Riva-Posse, P., Crowell, A., Tiruvadi, V., Obatusin, M., Veerakumar, A., Waters, A. C., Gross, R. E., et al. (2023) · Nature · doi:10.1038/s41586-023-06541-3 · Cited by 274
Chandrakumar, H., & Markovic, D. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2016.2645611 · Cited by 237
“Off-chip coupling capacitors can be used to increase the dc input impedance [29], but they become impractical for a miniaturized implant with a large number of recording channels.”
BackgroundAdvances in closed-loop deep brain stimulation devices
Parastarfeizabadi, M., & Kouzani, A. Z. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0295-1 · Cited by 232
“The suggested device fits in a 39cm(3) space, employing front-end filtering that guarantees the op-amp input to be within its normal operation area [86].”
BackgroundMethodInfluentialA mm-Sized Wireless Implantable Device for Electrical Stimulation of Peripheral Nerves
Charthad, J., Chang, T. C., Liu, Z., Sawaby, A., Weber, M. J., Baker, S., Gore, F., Felt, S. A., & Arbabian, A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2799623 · Cited by 230
“ral stimulation and recording, as thoroughly discussed in [51], [52] to enable a complete implant system for closed-loop neuromodulation [52], [53].”
BackgroundNeuromodulation: present and emerging methods
Luan, S., Williams, I., Nikolic, K., & Constandinou, T. G. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00027 · Cited by 162
Jiang, W., Hokhikyan, V., Chandrakumar, H., Karkare, V., & Markovic, D. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2016.2624989 · Cited by 140
Toward true closed-loop neuromodulation: artifact-free recording during stimulation.
Zhou, A., Johnson, B. C., & Muller, R. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2018.01.012 · Cited by 125
Conformable hybrid systems for implantable bioelectronic interfaces
Fallegger, F., Schiavone, G., & Lacour, S. P. (2020) · Advanced Materials · doi:10.1002/adma.201903904 · Cited by 113
Deep brain stimulation for psychiatric disorders: From focal brain targets to cognitive networks
Sullivan, C. R. P., Olsen, S., & Widge, A. S. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2020.117515 · Cited by 112
“With recent advances in technology, it has become possible to record patients’ brain activity directly from the DBS lead for long periods of time, often over a year (Stanslaski et al. 2012).”
BackgroundVeerakumar, A., Tiruvadi, V., Howell, B., Waters, A. C., Crowell, A. L., Voytek, B., Riva-Posse, P., Denison, L., Rajendra, J. K., Edwards, J. A., et al. (2019) · Journal of Neurophysiology · doi:10.1152/jn.00875.2018 · Cited by 89
Track-and-Zoom Neural Analog-to-Digital Converter With Blind Stimulation Artifact Rejection
Reza Pazhouhandeh, M., Chang, M., Valiante, T. A., & Genov, R. (2020) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.2991526 · Cited by 74
“Moreover, a high input impedance keeps the dc current low due to the EDO and avoids any tissue damage [31]–[33].”
BackgroundSmart, O., Choi, K. S., Riva-Posse, P., Tiruvadi, V., Rajendra, J., Waters, A. C., Crowell, A. L., Edwards, J., Gross, R. E., & Mayberg, H. S. (2018) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2018.00043 · Cited by 41
“The next phase of studies will examine brain oscillatory changes that are elicited during active chronic stimulation using hardware capable of simultaneous stimulation and recording off of the DBS lead (Stanslaski et al., 2012).”
BackgroundCulaclii, S., Kim, B., Lo, Y.-K., Li, L., & Liu, W. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2816464 · Cited by 34
“designs [3]–[11] and digital post-processing [12]–[17].”
Algorithm and hardware considerations for real-time neural signal on-implant processing
Zhang, Z., Savolainen, O. W., & Constandinou, T. G. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac5268 · Cited by 25
“Based on the Medtronic Activa PC neuromodulator, the Activa PC+S was designed in 2012 [54].”
MethodHuang, C.-W., Lai, C.-K., Hung, C.-C., Wu, C.-Y., & Ker, M.-D. (2023) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2023.3254891 · Cited by 16
Equalization for intracortical microstimulation artifact reduction.
Chu, P., Muller, R., Koralek, A., Carmena, J. M., Rabaey, J. M., & Gambini, S. (2013) · 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609483 · Cited by 13
“Finally in [8], still in the context of DBS, a combination of electrode placement and frequency separation is used.”
BackgroundMethod
Metadata
- Authors
- Stanslaski, S., Afshar, P., Cong, P., Giftakis, J., Stypulkowski, P., Carlson, D., Linde, D., Ullestad, D., Avestruz, A.-T., & Denison, T.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2012-07
- Volume
- 20
- Issue
- 4
- Pages
- 410-421
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2060583550
- Cited by
- 330
- References
- 29
- FWCI
- 5.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.