Is Accurate Mapping of EMG Signals on Kinematics Needed for Precise Online Myoelectric Control?
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
In this paper, we present a systematic analysis of the relationship between the accuracy of the mapping between EMG and hand kinematics and the control performance in goal-oriented tasks of three simultaneous and proportional myoelectric control algorithms: nonnegative matrix factorization (NMF), linear regression (LR), and artificial neural networks (ANN). The purpose was to investigate the impact of the precision of the kinematics estimation by a myoelectric controller for accurately complete goal-directed tasks. Nine naïve subjects performed a series of goal-directed myoelectric control tasks using the three algorithms, and their online performance was characterized by 6 indexes. The results showed that, although the three algorithms' mapping accuracies were significantly different, their online performance was similar. Moreover, for LR and ANN, the offline performance was not correlated to any of the online performance indexes, and only a weak correlation was found with three of them for NMF . We conclude that for reliable simultaneous and proportional myoelectric control, it is not necessary to achieve high accuracy in the mapping between EMG and kinematics. Rather, good online myoelectric control is achieved by the continuous interaction and adaptation of the user with the myoelectric controller through feedback (visual in the current study). Control signals generated by EMG with rather poor association with kinematic variables can still be fully exploited by the user for precise control. This conclusion explains the possibility of accurate simultaneous and proportional control over multiple degrees of freedom when using unsupervised algorithms, such as NMF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The information capacity of the human motor system in controlling the amplitude of movement.
Fitts, P. M. (1954) · Journal of Experimental Psychology · doi:10.1037/h0055392 · Cited by 6,466 · cited 1×
“represents the Shannon’s extension of Fitts’ law [21], as presented in [22]”
MethodThe information capacity of the human motor system in controlling the amplitude of movement.
Fitts, P. M. (1992) · Journal of Experimental Psychology: General · doi:10.1037/0096-3445.121.3.262 · Cited by 6,278
Myoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244 · cited 1×
“Currently, all commercial prostheses still use simple signal processing techniques for surface EMG,which only provide, at most, the sequential control of two degrees-offreedom (DoF) with an unintuitive switching command between the DoFs [3].”
BackgroundScheme, E., & Englehart, K. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0177 · Cited by 969 · cited 1×
“classes of forearm and hand motions [5].”
Control of Fast-Reaching Movements by Muscle Synergy Combinations
d'Avella, A., Portone, A., Fernandez, L., & Lacquaniti, F. (2006) · The Journal of Neuroscience · doi:10.1523/jneurosci.0830-06.2006 · Cited by 727 · cited 2×
“It was shown that this index is relatively unbiased with respect to mean square error when takes very small values [20].”
BackgroundMethodEmergence of a stable cortical map for neuroprosthetic control
Ganguly, K., & Carmena, J. M. (2009) · PLoS Biology · doi:10.1371/journal.pbio.1000153 · Cited by 578
Epidemiologic Overview of Individuals with Upper-Limb Loss and Their Reported Research Priorities
Atkins, D. J., Heard, D. C. Y., & Donovan, W. H. (1996) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-199600810-00003 · Cited by 508 · cited 2×
“In general, the clinical and commercial impact of myoelectric controlled prostheses remains very limited: only one out of four upper limb amputees uses this kind of prosthesis on a daily basis, even when the related costs are reimbursed [4].”
BackgroundJiang, N., Englehart, K. B., & Parker, P. A. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2007967 · Cited by 450 · cited 5×
“The algorithms selected for the comparison were artificial neural networks (ANN), linear regressor (LR), and nonnegative matrix factorization (NMF), as they have been used for SPC, and because it is known that their offline performance is different [11], [12].”
BackgroundMethodInfluentialSelf-citationMyoelectric Control of Artificial Limbs—Is There a Need to Change Focus? [In the Spotlight]
Jiang, N., Dosen, S., Muller, K.-R., & Farina, D. (2012) · IEEE Signal Processing Magazine · doi:10.1109/msp.2012.2203480 · Cited by 434 · cited 1×
“One of the reasons for failure of this type of myoelectric control in clinics is that it does not allow the simultaneous and proportional control (SPC) of two or more DoFs [6], which is the natural motor control approach.”
BackgroundSelf-citationDecoding the neural drive to muscles from the surface electromyogram
Farina, D., Holobar, A., Merletti, R., & Enoka, R. M. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.10.040 · Cited by 383 · cited 1×
“T HEMYOELECTRIC signal (EMG) is the electrical manifestationofmuscular contractions, andcontains richneural control information [1].”
BackgroundSelf-citation
Cited by
Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992
Self-citationAtzori, M., Cognolato, M., & Müller, H. (2016) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2016.00009 · Cited by 684
“Recently, semi-supervised methods and supervised methods were compared to evaluate the impact of precise kinematic estimations for accurately completing goal-directed tasks (Jiang et al., 2014).”
MethodBi, L., Feleke, A. >., & Guan, C. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.02.011 · Cited by 418
Farina, D., Vujaklija, I., Sartori, M., Kapelner, T., Negro, F., Jiang, N., Bergmeister, K., Andalib, A., Principe, J., & Aszmann, O. C. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0025 · Cited by 359
Self-citationCurrent state of digital signal processing in myoelectric interfaces and related applications
Hakonen, M., Piitulainen, H., & Visala, A. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.02.009 · Cited by 305
Prosthetic Myoelectric Control Strategies: A Clinical Perspective
Roche, A. D., Rehbaum, H., Farina, D., & Aszmann, O. C. (2014) · Current Surgery Reports · doi:10.1007/s40137-013-0044-8 · Cited by 261
Self-citationA survey of sensor fusion methods in wearable robotics
Novak, D., & Riener, R. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.012 · Cited by 252
Ison, M., & Artemiadis, P. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/051001 · Cited by 225
“Jiang et al [57] compare real-time performance to other classifiers with better offline statistics, noting that the intuitive controls underlying the NMF algorithm allow users to quickly adapt and achieve equal performance metrics.”
BackgroundResultInfluentialNgeo, J. G., Tamei, T., & Shibata, T. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-122 · Cited by 198
“When significant interaction was detected, focused ANOVA was conducted by fixing the levels of one of the interacting factors [10].”
MethodEvaluating EMG feature and classifier selection for application to partial-hand prosthesis control
Adewuyi, A. A., Hargrove, L. J., & Kuiken, T. A. (2016) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2016.00015 · Cited by 85
“Some previous research has demonstrated a minimal correlation between offline performance and usability with a virtual task (Lock et al., 2005; Jiang et al., 2014); however, other studies have shown significant correlation between offline classification error and real-time control (Smith et al.”
BackgroundBenchmarking Brain-Computer Interfaces Outside the Laboratory: The Cybathlon 2016
Novak, D., Sigrist, R., Gerig, N. J., Wyss, D., Bauer, R., Götz, U., & Riener, R. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00756 · Cited by 41
“Similar issues have been noted in other electrophysiological devices such as myoelectric prostheses (Jiang et al., 2014) and emphasize the need for online benchmarking.”
BackgroundLukyanenko, P., Dewald, H. A., Lambrecht, J., Kirsch, R. F., Tyler, D. J., & Williams, M. R. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00833-3 · Cited by 27
Use of probabilistic weights to enhance linear regression myoelectric control
Smith, L. H., Kuiken, T. A., & Hargrove, L. J. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/6/066030 · Cited by 15
“Both linear (Hahne et al., 2014, Jiang et al., 2014b, Smith et al., 2015a) and nonlinear (Jiang et al., 2012, Hahne et al., 2014, Kamavuako et al., 2012, Ameri et al., 2014, Ngeo et al., 2014, Muceli and Farina, 2012) methods of mapping EMG activity to prosthesis movement have been evaluated,…”
BackgroundMethodInfluential
Metadata
- Authors
- Jiang, N., Vujaklija, I., Rehbaum, H., Graimann, B., & Farina, D.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2014-05
- Volume
- 22
- Issue
- 3
- Pages
- 549-558
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2080596365
- Cited by
- 218
- References
- 29
- FWCI
- 9.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.