Is Accurate Mapping of EMG Signals on Kinematics Needed for Precise Online Myoelectric Control?
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
In this paper, we present a systematic analysis of the relationship between the accuracy of the mapping between EMG and hand kinematics and the control performance in goal-oriented tasks of three simultaneous and proportional myoelectric control algorithms: nonnegative matrix factorization (NMF), linear regression (LR), and artificial neural networks (ANN). The purpose was to investigate the impact of the precision of the kinematics estimation by a myoelectric controller for accurately complete goal-directed tasks. Nine naïve subjects performed a series of goal-directed myoelectric control tasks using the three algorithms, and their online performance was characterized by 6 indexes. The results showed that, although the three algorithms' mapping accuracies were significantly different, their online performance was similar. Moreover, for LR and ANN, the offline performance was not correlated to any of the online performance indexes, and only a weak correlation was found with three of them for NMF . We conclude that for reliable simultaneous and proportional myoelectric control, it is not necessary to achieve high accuracy in the mapping between EMG and kinematics. Rather, good online myoelectric control is achieved by the continuous interaction and adaptation of the user with the myoelectric controller through feedback (visual in the current study). Control signals generated by EMG with rather poor association with kinematic variables can still be fully exploited by the user for precise control. This conclusion explains the possibility of accurate simultaneous and proportional control over multiple degrees of freedom when using unsupervised algorithms, such as NMF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The information capacity of the human motor system in controlling the amplitude of movement.
Fitts, P. M. (1954) · Journal of Experimental Psychology · doi:10.1037/h0055392 · Cited by 6,466 · cited 1×
“represents the Shannon’s extension of Fitts’ law [21], as presented in [22]”
MethodThe information capacity of the human motor system in controlling the amplitude of movement.
Fitts, P. M. (1992) · Journal of Experimental Psychology: General · doi:10.1037/0096-3445.121.3.262 · Cited by 6,278
Myoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244 · cited 1×
“Currently, all commercial prostheses still use simple signal processing techniques for surface EMG,which only provide, at most, the sequential control of two degrees-offreedom (DoF) with an unintuitive switching command between the DoFs [3].”
BackgroundScheme, E., & Englehart, K. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0177 · Cited by 969 · cited 1×
“classes of forearm and hand motions [5].”
Control of Fast-Reaching Movements by Muscle Synergy Combinations
d'Avella, A., Portone, A., Fernandez, L., & Lacquaniti, F. (2006) · The Journal of Neuroscience · doi:10.1523/jneurosci.0830-06.2006 · Cited by 727 · cited 2×
“It was shown that this index is relatively unbiased with respect to mean square error when takes very small values [20].”
BackgroundMethodEmergence of a stable cortical map for neuroprosthetic control
Ganguly, K., & Carmena, J. M. (2009) · PLoS Biology · doi:10.1371/journal.pbio.1000153 · Cited by 578
Epidemiologic Overview of Individuals with Upper-Limb Loss and Their Reported Research Priorities
Atkins, D. J., Heard, D. C. Y., & Donovan, W. H. (1996) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-199600810-00003 · Cited by 508 · cited 2×
“In general, the clinical and commercial impact of myoelectric controlled prostheses remains very limited: only one out of four upper limb amputees uses this kind of prosthesis on a daily basis, even when the related costs are reimbursed [4].”
BackgroundJiang, N., Englehart, K. B., & Parker, P. A. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2007967 · Cited by 450 · cited 5×
“The algorithms selected for the comparison were artificial neural networks (ANN), linear regressor (LR), and nonnegative matrix factorization (NMF), as they have been used for SPC, and because it is known that their offline performance is different [11], [12].”
BackgroundMethodInfluentialSelf-citationMyoelectric Control of Artificial Limbs—Is There a Need to Change Focus? [In the Spotlight]
Jiang, N., Dosen, S., Muller, K.-R., & Farina, D. (2012) · IEEE Signal Processing Magazine · doi:10.1109/msp.2012.2203480 · Cited by 434 · cited 1×
“One of the reasons for failure of this type of myoelectric control in clinics is that it does not allow the simultaneous and proportional control (SPC) of two or more DoFs [6], which is the natural motor control approach.”
BackgroundSelf-citationDecoding the neural drive to muscles from the surface electromyogram
Farina, D., Holobar, A., Merletti, R., & Enoka, R. M. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.10.040 · Cited by 383 · cited 1×
“T HEMYOELECTRIC signal (EMG) is the electrical manifestationofmuscular contractions, andcontains richneural control information [1].”
BackgroundSelf-citationLinear and Nonlinear Regression Techniques for Simultaneous and Proportional Myoelectric Control
Hahne, J. M., Biebmann, F., Jiang, N., Rehbaum, H., Farina, D., Meinecke, F. C., Muller, K.-R., & Parra, L. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305520 · Cited by 365 · cited 5×
“, and is the bias vector, as defined in [11].”
BackgroundMethodResultSelf-citationLearning to integrate arbitrary signals from vision and touch
Ernst, M. O. (2007) · Journal of Vision · doi:10.1167/7.5.7 · Cited by 332 · cited 1×
“In agreement with our results, in visio-haptic sensory interactions, which is another man–machine interfacing area, humans can learn seemly uncorrelated arbitrary information from different sensory modalities and adapt to the changes in these sensory inputs [29].”
ResultClassification of Simultaneous Movements Using Surface EMG Pattern Recognition
Young, A. J., Smith, L. H., Rouse, E. J., & Hargrove, L. J. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2232293 · Cited by 320 · cited 1×
“Although simultaneous activation of two classes by pattern recognition was recently achieved by enriching the training set [7], this approach would become impractical when the number of DoFs or motions increases.”
BackgroundA Note on the Information-Theoretic Basis for Fitts’ Law
MacKenzie, I. S. (1989) · Journal of Motor Behavior · doi:10.1080/00222895.1989.10735486 · Cited by 315
Muceli, S., & Farina, D. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2178039 · Cited by 285 · cited 2×
“The efficacy of this scheme in realizing SPC has been now extensively demonstrated in able-bodied subjects [8], [10], as well as transradial amputees [9], [13], both in offline analysis [8]–[11], and in online validations [13].”
BackgroundResultSelf-citationJiang, N., Rehbaum, H., Vujaklija, I., Graimann, B., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2278411 · Cited by 269 · cited 6×
“The efficacy of this scheme in realizing SPC has been now extensively demonstrated in able-bodied subjects [8], [10], as well as transradial amputees [9], [13], both in offline analysis [8]–[11], and in online validations [13].”
BackgroundMethodResultSelf-citationEMG-Based Control of a Robot Arm Using Low-Dimensional Embeddings
Artemiadis, P. K., & Kyriakopoulos, K. J. (2010) · IEEE Transactions on Robotics · doi:10.1109/tro.2009.2039378 · Cited by 267 · cited 1×
“The observation that no “super machine intelligence” is necessary for robust SPC myoelectric control is also noted by other researchers in the literature, where the concept of “human embedded control” is used to describe the user’s ability in controlling multi-DoF tasks through poorly calibrated controllers [27], [28].”
BackgroundNielsen, J. L. G., Holmgaard, S., Jiang, N., Englehart, K. B., Farina, D., & Parker, P. A. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2068298 · Cited by 260 · cited 2×
“For example, supervised regression methods, such as artificial neural networks (ANN), can be used to estimate joint kinetics [8] and kinematics [9]–[11] of complex wrist contractions involving multiple DoFs.”
BackgroundMethodSelf-citationOrtiz-Catalan, M., Brånemark, R., & Håkansson, B. (2013) · Source Code for Biology and Medicine · doi:10.1186/1751-0473-8-11 · Cited by 232 · cited 1×
“In a more recent study, inconsistencies were found in the offline and online classification accuracy of several patter recognition algorithms [17].”
BackgroundWilliams, M. R., & Kirsch, R. F. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2006216 · Cited by 189 · cited 1×
“It is important to note that, even though the definitions of TP and in the current study are similar to those in [23], the optimal path considered here was not the straight line from the starting point to the target point, as the control variables were the angles in the two DoFs and not in the Cartesian coordinates as…”
Jiang, N., Vest-Nielsen, J. L., Muceli, S., & Farina, D. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-42 · Cited by 181 · cited 4×
“For example, supervised regression methods, such as artificial neural networks (ANN), can be used to estimate joint kinetics [8] and kinematics [9]–[11] of complex wrist contractions involving multiple DoFs.”
BackgroundMethodResultSelf-citationMuceli, S., Jiang, N., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2282898 · Cited by 172 · cited 1×
“The results from ANN and LR were consistent with those shown in previous studies [9], [11], [25], [26].”
ResultSelf-citationREAL-TIME MYOELECTRIC CONTROL IN A VIRTUAL ENVIRONMENT TO RELATE USABILITY VS. ACCURACY
Lock, B. A., Englehart, K. B., & Hudgins, B. (2005) · DukeSpace (Duke University) · Cited by 122
Scheme, E. J., & Englehart (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2226189 · Cited by 89
Hill, W., Stavdahl, Ø., Hermansson, L. N., Kyberd, P., Swanson, S., & Hubbard, S. (2009) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/jpo.0b013e3181a1d2dc · Cited by 53 · cited 1×
“The success in these efforts made it possible to move the focus of SPC research from the Function domain into the Activity domain, as defined by the upper limb prosthetic outcome measures (ULPOM) group [14].”
BackgroundSimultaneous and proportional control of 2D wrist movements with myoelectric signals
Hahne, J. M., Rehbaum, H., Bießmann, F., Meinecke, F. C., Müller, K. R., Jiang, N., Farina, D., & Parra, L. C. (2012) · Machine learning for signal processing ... · doi:10.1109/mlsp.2012.6349712 · Cited by 49 · cited 1×
“The results from ANN and LR were consistent with those shown in previous studies [9], [11], [25], [26].”
ResultSelf-citationRehbaum, H., Jiang, N., Paredes, L. P., Amsuess, S., Graimann, B., & Farina, D. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346187 · Cited by 45 · cited 1×
“The subjects were instructed to move the arrow so that its tip would stay within a circle for at least 300 ms within a 20 s time interval, as in previous studies [13], [19].”
ResultSelf-citationMultifunction control of prostheses using the myoelectric signal
Englehart, K. B., Parker, P. A., & Hudgins, B. S. (2000) · The CRC Press international series on computational intelligence/International series on computational intelligence · doi:10.1201/9781420042122.ch5 · Cited by 36 · cited 1×
“2287383 control signal for multi-function upper limb prostheses for more than six decades [2].”
BackgroundTask discrimination from myoelectric activity: A learning scheme for EMG-based interfaces
Liarokapis, M. V., Artemiadis, P., & Kyriakopoulos, K. J. (2013) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2013.6650366 · Cited by 25 · cited 1×
“The observation that no “super machine intelligence” is necessary for robust SPC myoelectric control is also noted by other researchers in the literature, where the concept of “human embedded control” is used to describe the user’s ability in controlling multi-DoF tasks through poorly calibrated controllers [27], [28].”
Background
Cited by
Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992
Self-citationAtzori, M., Cognolato, M., & Müller, H. (2016) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2016.00009 · Cited by 684
“Recently, semi-supervised methods and supervised methods were compared to evaluate the impact of precise kinematic estimations for accurately completing goal-directed tasks (Jiang et al., 2014).”
MethodBi, L., Feleke, A. >., & Guan, C. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.02.011 · Cited by 418
Farina, D., Vujaklija, I., Sartori, M., Kapelner, T., Negro, F., Jiang, N., Bergmeister, K., Andalib, A., Principe, J., & Aszmann, O. C. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0025 · Cited by 359
Self-citationCurrent state of digital signal processing in myoelectric interfaces and related applications
Hakonen, M., Piitulainen, H., & Visala, A. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.02.009 · Cited by 305
Metadata
- Authors
- Jiang, N., Vujaklija, I., Rehbaum, H., Graimann, B., & Farina, D.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2014-05
- Volume
- 22
- Issue
- 3
- Pages
- 549-558
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2080596365
- Cited by
- 218
- References
- 29
- FWCI
- 9.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.