Dexterous Control of a Prosthetic Hand Using Fine-Wire Intramuscular Electrodes in Targeted Extrinsic Muscles
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Restoring dexterous motor function equivalent to that of the human hand after amputation is one of the major goals in rehabilitation engineering. To achieve this requires the implementation of a effortless human-machine interface that bridges the artificial hand to the sources of volition. Attempts to tap into the neural signals and to use them as control inputs for neuroprostheses range in invasiveness and hierarchical location in the neuromuscular system. Nevertheless today, the primary clinically viable control technique is the electromyogram measured peripherally by surface electrodes. This approach is neither physiologically appropriate nor dexterous because arbitrary finger movements or hand postures cannot be obtained. Here we demonstrate the feasibility of achieving real-time, continuous and simultaneous control of a multi-digit prosthesis directly from forearm muscles signals using intramuscular electrodes on healthy subjects. Subjects contracted physiologically appropriate muscles to control four degrees of freedom of the fingers of a physical robotic hand independently. Subjects described the control as intuitive and showed the ability to drive the hand into 12 postures without explicit training. This is the first study in which peripheral neural correlates were processed in real-time and used to control multiple digits of a physical hand simultaneously in an intuitive and direct way.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
Direct neural sensory feedback and control of a prosthetic arm
Dhillon, G. S., & Horch, K. W. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.856072 · Cited by 573
The optimal controller delay for myoelectric prostheses
Farrell, T. R., & Weir, R. F. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891391 · Cited by 438
Self-citationDouble nerve intraneural interface implant on a human amputee for robotic hand control
Rossini, P. M., Micera, S., Benvenuto, A., Carpaneto, J., Cavallo, G., Citi, L., Cipriani, C., Denaro, L., Denaro, V., Di Pino, G., et al. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.001 · Cited by 396 · cited 3×
“When making an analytic comparison between this and previous works on physiologic control of intrinsic hand movements using peripheral information [1]–[3], [26]–[28] significant differences can be found.”
BackgroundResultSelf-citationThe SmartHand transradial prosthesis
Cipriani, C., Controzzi, M., & Carrozza, M. C. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-29 · Cited by 286
Self-citationOnline Myoelectric Control of a Dexterous Hand Prosthesis by Transradial Amputees
Cipriani, C., Antfolk, C., Controzzi, M., Lundborg, G., Rosen, B., Carrozza, M. C., & Sebelius, F. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2108667 · Cited by 233 · cited 1×
“[26] demonstrated significant classification accuracies 90% of ten different hand postures (offline processing) in a transradial amputee; Cipriani and colleagues [27] showed real-time control of seven postures with average accuracy of 79% across five transradial amputees.”
BackgroundSelf-citationDevelopment of an Implantable Myoelectric Sensor for Advanced Prosthesis Control
Merrill, D. R., Lockhart, J., Troyk, P. R., Weir, R. F., & Hankin, D. L. (2011) · Artificial Organs · doi:10.1111/j.1525-1594.2011.01219.x · Cited by 117
Self-citationJia, X., Koenig, M. A., Zhang, X., Zhang, J., Chen, T., & Chen, Z. (2007) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2007.02.021 · Cited by 70 · cited 1×
“However, previous studies either demonstrated proportional control of only one DoF [1], [2] or the control of multiple DoFs using pattern recognition which by definition allows for a finite number of postures/grasps [3], [26]–[28].”
Background
Research works printed but not linked: 21
- 10.1109/TBME.2006.881774 · DOI
- 10.1113/jphysiol.1994.sp020312 · DOI · Paper page
- 10.1152/jn.00797.2009 · DOI
- 10.1111/j.1469-7793.1997.693bj.x · DOI
- 10.1152/jn.00287.2003 · DOI
- 10.1113/jphysiol.2011.217810 · DOI
- birdwell, 2011, Investigation of Extrinsic Finger and Thumb Muscles to Command Individual Digits on a Multi-Functional Artificial Hand
- 10.1152/jn.00748.2012 · DOI
- 10.1109/TNSRE.2010.2047590 · DOI · Paper page
- 10.1109/JBHI.2013.2249590 · DOI · Paper page
- 10.1016/S0140-6736(07)60193-7 · DOI · Paper page
- 10.1109/TBME.2012.2197210 · DOI · Paper page
- 10.1109/TBME.2008.2005942 · DOI · Paper page
- 10.1109/RBME.2010.2085429 · DOI · Paper page
- 10.1115/1.4004653 · DOI
- 10.1002/0471678384 · DOI · Paper page
- basmajian, 1962, A new bipolar electrode for electromyography, J Appl Physiol, 17, 849, 10.1152/jappl.1962.17.5.849 · DOI · Paper page
- keller, 1947, ?Studies to determine the functional requirements for hand arm prosthesis ?
- 10.1109/TBME.1978.326283 · DOI
- 10.1523/JNEUROSCI.2869-07.2008 · DOI · Paper page
- 10.1109/TBME.2008.2005485 · DOI · Paper page
Cited by
Farina, D., Vujaklija, I., Sartori, M., Kapelner, T., Negro, F., Jiang, N., Bergmeister, K., Andalib, A., Principe, J., & Aszmann, O. C. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0025 · Cited by 359
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Self-citationWendelken, S., Page, D. M., Davis, T., Wark, H. A. C., Kluger, D. T., Duncan, C., Warren, D. J., Hutchinson, D. T., & Clark, G. A. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0320-4 · Cited by 216
“using EMG signals and/or classifier decodes, which have been limited to only 4 DOFs [36].”
MethodKaya, M., Binli, M. K., Ozbay, E., Yanar, H., & Mishchenko, Y. (2018) · Scientific Data · doi:10.1038/sdata.2018.211 · Cited by 178
Is it Finger or Wrist Dexterity That is Missing in Current Hand Prostheses?
Montagnani, F., Controzzi, M., & Cipriani, C. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2398112 · Cited by 161
“, using intramuscular myoelectric signals [19]) for wrist movements—in particular the pronation/supination and the flexion/ extension [20]–[23] – it was demonstrated using clinically available surface electrodes, and clinically viable systems.”
Self-citation
Metadata
- Authors
- Cipriani, C., Segil, J. L., Birdwell, J. A., & Weir, R. F. F.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2014-07
- Volume
- 22
- Issue
- 4
- Pages
- 828-836
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2039537472
- Cited by
- 81
- References
- 8
- FWCI
- 5.96
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dexterous Control of a Prosthetic Hand Using Fine-Wire Intramuscular Electrodes in Targeted Extrinsic Muscles. https://app.cochat.ai/papers/10.1109/tnsre.2014.2301234
- The paper
- Cipriani, C., Segil, J. L., Birdwell, J. A., & Weir, R. F. F. (2014). Dexterous Control of a Prosthetic Hand Using Fine-Wire Intramuscular Electrodes in Targeted Extrinsic Muscles. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2014.2301234
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.