Is it Finger or Wrist Dexterity That is Missing in Current Hand Prostheses?
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Building prostheses with dexterous motor function equivalent to that of the human hand is one of the ambitious goals of bioengineers. State of art prostheses lack several degrees of freedom (DoF) and force the individuals to compensate for them by changing the motions of their arms and body. However, such compensatory movements often result in residual limb pain and overuse syndromes. Significant efforts were spent in designing artificial hands with multiple allowed grasps but little work has been done with regards to wrist design, regardless the fact that the wrist contributes significantly to the execution of upper limb motor tasks. We hypothesized that a single DoF hand with wrist flexion/extension allowed function comparable to a highly performant multi DoF hand without wrist flexion/extension. To assess this we compared four emulated architectures of hand-wrist prostheses using the Southampton Hand Assessment Procedure and evaluating the extent of compensatory movements with unimpaired subjects wearing ortheses. Our findings show indeed that shifting the dexterity from the hand to the wrist could preserve the ability of transradial amputees in performing common tasks with limited effect on the compensatory movements. Hence, this study invites rehabilitation engineers to focus on novel artificial wrist architectures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001 · cited 1×
“Examples of robotic hands that attempted to do so are the DARPA Revolutionizing Prosthetics Proto 2 [16], and in a simplified manner the SmartHand [10], the Vanderbilt Multi-grasp hand [13], the DEKA [14] and the Azzurra hands [15], to cite a few.”
Self-citationFarina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992 · cited 1×
“To date the most technologically advanced prostheses are the myoelectric ones [1].”
Mechanical design and performance specifications of anthropomorphic prosthetic hands: A review
Belter, J. T., Segil, J. L., Dollar, A. M., & Weir, R. F. (2013) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2011.10.0188 · Cited by 716 · cited 1×
“Several multi-digit hands have seen the light in research laboratories around the world and few designs actually reached the clinic [12]–[16] and the markets [17].”
Light, C. M., Chappell, P. H., & Kyberd, P. J. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2002.32737 · Cited by 417 · cited 6×
“The subject performed the task until satisfied that the fastest possible time was achieved [30].”
InfluentialClassification of Simultaneous Movements Using Surface EMG Pattern Recognition
Young, A. J., Smith, L. H., Rouse, E. J., & Hargrove, L. J. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2232293 · Cited by 320
The SmartHand transradial prosthesis
Cipriani, C., Controzzi, M., & Carrozza, M. C. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-29 · Cited by 286 · cited 1×
“Several multi-digit hands have seen the light in research laboratories around the world and few designs actually reached the clinic [12]–[16] and the markets [17].”
Self-citationJiang, N., Rehbaum, H., Vujaklija, I., Graimann, B., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2278411 · Cited by 269 · cited 1×
“, [22] demonstrated performant HMIs able to control in a simultaneous and proportional fashion the three DoFs of the wrist using surface myoelectric signals.”
Resnik, L., Klinger, S. L., & Etter, K. (2014) · Prosthetics & Orthotics International · doi:10.1177/0309364613506913 · Cited by 214 · cited 4×
“Weir et al., and Resnik et al., presented the wrists for multi-DoF prosthetic limbs, namely the DARPA Revolutionizing Prosthetics Proto 2 arm [16] and the DEKA arm [14].”
InfluentialDesign of a Multifunctional Anthropomorphic Prosthetic Hand With Extrinsic Actuation
Dalley, S. A., Wiste, T. E., Withrow, T. J., & Goldfarb, M. (2009) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2009.2033113 · Cited by 204
Jiang, N., Vest-Nielsen, J. L., Muceli, S., & Farina, D. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-42 · Cited by 181
Compensatory movements of transradial prosthesis users during common tasks
Carey, S. L., Jason Highsmith, M., Maitland, M. E., & Dubey, R. V. (2008) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2008.05.008 · Cited by 179 · cited 5×
“Each task was performed three times with each hand-wrist configuration, as in similar studies [2], [3], [32].”
InfluentialMusculoskeletal Pain and Overuse Syndromes in Adult Acquired Major Upper-Limb Amputees
Østlie, K., Franklin, R. J., Skjeldal, O. H., Skrondal, A., & Magnus, P. M. (2011) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2011.06.026 · Cited by 161 · cited 1×
“This was an expected result as indicated by the percentage of myoelectric hand users with shoulder injuries or posture problems [5], [6], [7].”
Closed-loop control in prosthetic systems: Historical perspective
Childress, D. S. (1980) · Annals of Biomedical Engineering · doi:10.1007/bf02363433 · Cited by 158 · cited 2×
“Powered prostheses have existed for roughly one hundred years [10].”
The nature of human prehension: Three dextrous hands in one
Iberall, T. (2005) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.1987.1087813 · Cited by 146
Impact of impaired wrist motion on hand and upper-extremity performance
Adams, B. D., Grosland, N. M., Murphy, D., & McCullough, M. B. A. (2003) · The Journal Of Hand Surgery · doi:10.1016/s0363-5023(03)00424-6 · Cited by 140 · cited 2×
“The hand-wrist configurations, were emulated using custom built ortheses worn by able bodied subjects, as in previous studies [2], [28], [29].”
Design of Artificial Hands: A Review
Controzzi, M., Cipriani, C., & Carrozza, M. C. (2014) · Springer tracts in advanced robotics · doi:10.1007/978-3-319-03017-3_11 · Cited by 135 · cited 1×
“Engineers and researchers involved in this field have spent significant efforts in designing artificial hands with enhanced dexterity, trying to mimic the complex kinematical architecture of the human hand [11].”
Self-citationCharacterization of Compensatory Trunk Movements During Prosthetic Upper Limb Reaching Tasks
Metzger, A. J., Dromerick, A. W., Holley, R. J., & Lum, P. S. (2012) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2012.03.011 · Cited by 128 · cited 1×
“In this work, the pronation/supination movement was allowed in all of the configurations, thus the relevant compensatory movements were all at the level of the shoulder and the trunk [29], [34].”
Major, M. J., Stine, R. L., Heckathorne, C. W., Fatone, S., & Gard, S. A. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-132 · Cited by 104 · cited 5×
“Tenmarkers were placed in order to assess off-line the movements of the trunk, right shoulder and arm, as done in similar studies [3], [32], [33] (Fig.”
InfluentialOveruse Syndrome and the Unilateral Upper Limb Amputee: Consequences and Prevention
Gambrell, C. R. (2008) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/jpo.0b013e31817ecb16 · Cited by 97 · cited 1×
“This was an expected result as indicated by the percentage of myoelectric hand users with shoulder injuries or posture problems [5], [6], [7].”
Case Studies to Demonstrate the Range of Applications of the Southampton Hand Assessment Procedure
Kyberd, P., Murgia, A., Gasson, M. N., Tjerks, T., Metcalf, C., Chappell, P. H., Warwick, K., Lawson, S. E. M., & Barnhill, T. (2009) · British Journal of Occupational Therapy · doi:10.1177/030802260907200506 · Cited by 97 · cited 1×
“These results agree with the minimal SHAP increase that is considered to be statistically significant, namely the Smallest Real Difference as calculated by Kyberd and colleagues [36]; notably, the IOFs of B and C were not statistically significant different measures , whereas they were both significantly different mea…”
The i-LIMB Hand and the DMC Plus Hand Compared: A Case Report
Van Der Niet, O., Reinders-Messelink, H. A., Bongers, R. M., Bouwsema, H., & Van Der Sluis, C. K. (2010) · Prosthetics & Orthotics International · doi:10.3109/03093641003767207 · Cited by 87 · cited 1×
“It was used already in a number of studies in the field of prosthetic devices [37], [38], [39].”
Cipriani, C., Segil, J. L., Birdwell, J. A., & Weir, R. F. F. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2301234 · Cited by 81 · cited 1×
“, using intramuscular myoelectric signals [19]) for wrist movements—in particular the pronation/supination and the flexion/ extension [20]–[23] – it was demonstrated using clinically available surface electrodes, and clinically viable systems.”
Self-citationMurgia, A., Kyberd, P., & Barnhill, T. (2010) · Gait & Posture · doi:10.1016/j.gaitpost.2009.11.007 · Cited by 71 · cited 2×
“Tenmarkers were placed in order to assess off-line the movements of the trunk, right shoulder and arm, as done in similar studies [3], [32], [33] (Fig.”
Almstr�m, C., Herberts, P., & K�rner, L. (1981) · International Orthopaedics · doi:10.1007/bf00286094 · Cited by 67 · cited 4×
“flexion/extension and pronation/supination [24].”
InfluentialTwo-degree-of-freedom powered prosthetic wrist
Kyberd, P., Lemaire, E. D., Scheme, E., MacPhail, C. M., Goudreau, L., Bush, G., & Brookeshaw, M. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.07.0137 · Cited by 65 · cited 2×
“mechanism for the ToMPAW modular arm [9].”
Simultaneous, Proportional, Multi-axis Prosthesis Control using Multichannel Surface EMG
Yatsenko, D., McDonnall, D., & Guillory, K. S. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353749 · Cited by 54 · cited 2×
“, using intramuscular myoelectric signals [19]) for wrist movements—in particular the pronation/supination and the flexion/ extension [20]–[23] – it was demonstrated using clinically available surface electrodes, and clinically viable systems.”
Complications Following an Amputation
Yoo, S. (2013) · Physical Medicine and Rehabilitation Clinics of North America · doi:10.1016/j.pmr.2013.09.003 · Cited by 52 · cited 1×
“[4]–[8].”
Objectifying the Functional Advantages of Prosthetic Wrist Flexion
Bertels, T., Schmalz, T., & Ludwigs, E. (2009) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/jpo.0b013e3181a10f46 · Cited by 48
Kyberd, P. (2011) · Prosthetics and Orthotics International · doi:10.1177/0309364611418554 · Cited by 43 · cited 1×
“It was used already in a number of studies in the field of prosthetic devices [37], [38], [39].”
Comparative study of state-of-the-art myoelectric controllers for multigrasp prosthetic hands
Segil, J. L., Controzzi, M., Weir, R. F. F., & Cipriani, C. (2014) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2014.01.0014 · Cited by 33
Self-citationMontagnani, F., Controzzi, M., & Cipriani, C. (2013) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2013.6739477 · Cited by 28 · cited 1×
“and colleagues proposed a 2 DoFs wrist in which the stiffness could be switched in order to facilitate the reaching and holding phases of a grasp [26].”
Self-citationTHE INTRINSIC HAND – A 22 DEGREE-OF-FREEDOM ARTIFICIAL HAND-WRIST REPLACEMENT
Weir, R. F. F., Mitchell, M., Clark, S. L., Puchhammer, G., Haslinger, M. J., Grausenburger, R., Kumar, N., Hofbauer, R., Kuschnigg, P., Cornelius, V., et al. (2008) · DukeSpace (Duke University) · Cited by 24
The influence of passive wrist joints on the functionality of prosthetic hands
Kyberd, P. (2011) · Prosthetics and Orthotics International · doi:10.1177/0309364611426905 · Cited by 17 · cited 1×
“It was used already in a number of studies in the field of prosthetic devices [37], [38], [39].”
THE INTRINSIC HAND - A 22 DEGREE-OF-FREEDOM ARTIFICIAL HAND-WRIST REPLACEMENT
Bock, O. (2008) · Cited by 9
Possibilities for control of powered devices by myoelectric signals
Herberts, P., & Petersén, I. (1970) · Journal of Rehabilitation Medicine · doi:10.2340/16501977197024164170 · Cited by 9 · cited 1×
“2 grip types and a 2 DoFs wrist [25]: concepts employed in it”
Cited by
Ameri, A., Akhaee, M. A., Scheme, E., & Englehart, K. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2962189 · Cited by 171
“Wrist motions were studied in this work because of their importance in upper-limb motor tasks [25].”
Evaluating EMG feature and classifier selection for application to partial-hand prosthesis control
Adewuyi, A. A., Hargrove, L. J., & Kuiken, T. A. (2016) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2016.00015 · Cited by 85
Metadata
- Authors
- Montagnani, F., Controzzi, M., & Cipriani, C.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2015-07
- Volume
- 23
- Issue
- 4
- Pages
- 600-609
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2145517458
- Cited by
- 161
- References
- 35
- FWCI
- 4.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.