Movement Performance of Human–Robot Cooperation Control Based on EMG-Driven Hill-Type and Proportional Models for an Ankle Power-Assist Exoskeleton Robot
The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Abstract
Although the merits of electromyography (EMG)-based control of powered assistive systems have been certified, the factors that affect the performance of EMG-based human-robot cooperation, which are very important, have received little attention. This study investigates whether a more physiologically appropriate model could improve the performance of human-robot cooperation control for an ankle power-assist exoskeleton robot. To achieve the goal, an EMG-driven Hill-type neuromusculoskeletal model (HNM) and a linear proportional model (LPM) were developed and calibrated through maximum isometric voluntary dorsiflexion (MIVD). The two control models could estimate the real-time ankle joint torque, and HNM is more accurate and can account for the change of the joint angle and muscle dynamics. Then, eight healthy volunteers were recruited to wear the ankle exoskeleton robot and complete a series of sinusoidal tracking tasks in the vertical plane. With the various levels of assist based on the two calibrated models, the subjects were instructed to track the target displayed on the screen as accurately as possible by performing ankle dorsiflexion and plantarflexion. Two measurements, the root mean square error (RMSE) and root mean square jerk (RMSJ), were derived from the assistant torque and kinematic signals to characterize the movement performances, whereas the amplitudes of the recorded EMG signals from the tibialis anterior (TA) and the gastrocnemius (GAS) were obtained to reflect the muscular efforts. The results demonstrated that the muscular effort and smoothness of tracking movements decreased with an increase in the assistant ratio. Compared with LPM, subjects made lower physical efforts and generated smoother movements when using HNM, which implied that a more physiologically appropriate model could enable more natural and human-like human-robot cooperation and has potential value for improvement of human-exoskeleton interaction in future applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Muscle and tendon: properties, models, scaling, and application to biomechanics and motor control.
Zajac, F. E. (1989) · PubMed · Cited by 3,673
The heat of shortening and the dynamic constants of muscle
Hill, A. V. (1938) · Proceedings of the Royal Society of London. Series B - Biological Sciences · doi:10.1098/rspb.1938.0050 · Cited by 3,669
An interactive graphics-based model of the lower extremity to study orthopaedic surgical procedures
Delp, S. L., Loan, J. P., Hoy, M. G., Zajac, F. E., Topp, E. L., & Rosen, J. M. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102791 · Cited by 2,005
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Robot-aided neurorehabilitation
Krebs, H. I., Hogan, N., Aisen, M. L., & Volpe, B. T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.662623 · Cited by 1,425
Introduction to Surface Electromyography
Cram, J. R., Kasman, G. S., & Holtz, J. (1998) · Cited by 1,199
An EMG-driven musculoskeletal model to estimate muscle forces and knee joint moments in vivo
Lloyd, D. G., & Besier, T. F. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00010-1 · Cited by 1,199
Dynamic Optimization of Human Walking
Anderson, F. C., & Pandy, M. G. (2001) · Journal of Biomechanical Engineering · doi:10.1115/1.1392310 · Cited by 1,107
Buchanan, T. S., Lloyd, D. G., Manal, K., & Besier, T. F. (2004) · Journal of Applied Biomechanics · doi:10.1123/jab.20.4.367 · Cited by 941
Introduction to Surface Electromyography
Pope, G. D. (1998) · Physiotherapy · doi:10.1016/s0031-9406(05)61482-4 · Cited by 841
Electromechanical delay in human skeletal muscle under concentric and eccentric contractions
Cavanagh, P. R., & Komi, P. V. (1979) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00431022 · Cited by 802
Movement Smoothness Changes during Stroke Recovery
Rohrer, B., Fasoli, S., Krebs, H. I., Hughes, R., Volpe, B., Frontera, W. R., Stein, J., & Hogan, N. (2002) · The Journal of Neuroscience · doi:10.1523/jneurosci.22-18-08297.2002 · Cited by 767
Role of Cocontraction in Arm Movement Accuracy
Gribble, P. L., Mullin, L. I., Cothros, N., & Mattar, A. (2003) · Journal of Neurophysiology · doi:10.1152/jn.01020.2002 · Cited by 660
On the Control of the Berkeley Lower Extremity Exoskeleton (BLEEX)
Kazerooni, H., Racine, J.-L., Huang, L., & Steger, R. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570790 · Cited by 594
Support Vector Machine-Based Expert System for Reliable Heartbeat Recognition
Osowski, S., Hoai, L. T., & Markiewicz, T. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.824138 · Cited by 536
Hoy, M. G., Zajac, F. E., & Gordon, M. E. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90349-8 · Cited by 525
Wearable Robots: Biomechatronic Exoskeletons
(2008) · Wiley eBooks · doi:10.1002/9780470987667 · Cited by 517
Computer Modeling and Simulation of Human Movement
Pandy, M. G. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.245 · Cited by 471
Lower Limb Wearable Robots for Assistance and Rehabilitation: A State of the Art
Huo, W., Mohammed, S., Moreno, J. C., & Amirat, Y. (2016) · IEEE Systems Journal · doi:10.1109/jsyst.2014.2351491 · Cited by 455
Sensitivity of Smoothness Measures to Movement Duration, Amplitude, and Arrests
Hogan, N., & Sternad, D. (2009) · Journal of Motor Behavior · doi:10.3200/35-09-004-rc · Cited by 440
A myosignal-based powered exoskeleton system
Rosen, J., Brand, M., Fuchs, M. B., & Arcan, M. (2001) · IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans · doi:10.1109/3468.925661 · Cited by 437
A QUASI-PASSIVE LEG EXOSKELETON FOR LOAD-CARRYING AUGMENTATION
WALSH, C. J., ENDO, K., & HERR, H. (2007) · International Journal of Humanoid Robotics · doi:10.1142/s0219843607001126 · Cited by 427
A Human--Exoskeleton Interface Utilizing Electromyography
Fleischer, C., & Hommel, G. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.926860 · Cited by 412
Design of a Cable-Driven Arm Exoskeleton (CAREX) for Neural Rehabilitation
Mao, Y., & Agrawal, S. K. (2012) · IEEE Transactions on Robotics · doi:10.1109/tro.2012.2189496 · Cited by 409
Design and control of an exoskeleton for the elderly and patients
Kong, K., & Jeon, D. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.878550 · Cited by 403
Intention-Based EMG Control for Powered Exoskeletons
Lenzi, T., De Rossi, S. M. M., Vitiello, N., & Carrozza, M. C. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2198821 · Cited by 400
Hybrid Control of the Berkeley Lower Extremity Exoskeleton (BLEEX)
Kazerooni, H., Steger, R., & Huang, L. (2006) · The International Journal of Robotics Research · doi:10.1177/0278364906065505 · Cited by 382
Determination of Muscle Orientations and Moment Arms
An, K. N., Takahashi, K., Harrigan, T. P., & Chao, E. Y. (1984) · Journal of Biomechanical Engineering · doi:10.1115/1.3138494 · Cited by 367
Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression
Rocon, E., Belda-Lois, J. M., Ruiz, A. F., Manto, M., Moreno, J. C., & Pons, J. L. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903917 · Cited by 349
Metabolic energy expenditure and the regulation of movement economy
Sparrow, W. A., & Newell, K. M. (1998) · Psychonomic Bulletin & Review · doi:10.3758/bf03212943 · Cited by 281
Customized interactive robotic treatment for stroke: EMG-triggered therapy
Dipietro, L., Ferraro, M., Palazzolo, J. J., Krebs, H. I., Volpe, B. T., & Hogan, N. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.850423 · Cited by 241
Detection of self-paced reaching movement intention from EEG signals
Lew, E. (2012) · Frontiers in Neuroengineering · doi:10.3389/fneng.2012.00013 · Cited by 227
Song, R., Tong, K.-Y., Hu, X., & Li, L. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.926707 · Cited by 195
Self-citationA Powered Finger–Thumb Wearable Hand Exoskeleton With Self-Aligning Joint Axes
Cempini, M., Cortese, M., & Vitiello, N. (2015) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2014.2315528 · Cited by 193
A Model of Load Sharing Between Muscles and Soft Tissues at the Human Knee During Static Tasks
Lloyd, D. G., & Buchanan, T. S. (1996) · Journal of Biomechanical Engineering · doi:10.1115/1.2796019 · Cited by 181
An EMG-driven model to estimate muscle forces and joint moments in stroke patients
Shao, Q., Bassett, D. N., Manal, K., & Buchanan, T. S. (2009) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2009.09.002 · Cited by 178
Review of hybrid exoskeletons to restore gait following spinal cord injury
del-Ama, A. J., Koutsou, A. D., Moreno, J. C., de-los-Reyes, A., Gil-Agudo, N., & Pons, J. L. (2012) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2011.03.0043 · Cited by 174
MANAL, K. T., & Buchanan, T. S. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00152-0 · Cited by 159
Neptune, R. R., & Hull, M. L. (1998) · Journal of Biomechanical Engineering · doi:10.1115/1.2797999 · Cited by 145
Performances of Hill-Type and Neural Network Muscle Models—Toward a Myosignal-Based Exoskeleton
Rosén, J., Fuchs, M. B., & Arcan, M. (1999) · Computers and Biomedical Research · doi:10.1006/cbmr.1999.1524 · Cited by 142
Stand-Alone Wearable Power Assist Suit –Development and Availability–
Ishii, M., YAMAMOTO, K., & HYODO, K. (2005) · Journal of Robotics and Mechatronics · doi:10.20965/jrm.2005.p0575 · Cited by 130
Control and system identification for the Berkeley lower extremity exoskeleton (BLEEX)
Ghan, J., Steger, R., & Kazerooni, H. (2006) · Advanced Robotics · doi:10.1163/156855306778394012 · Cited by 125
Lee, H.-D., Lee, B.-K., Kim, W., Han, J., Shin, K., & Han, C.-S. (2014) · Mechatronics · doi:10.1016/j.mechatronics.2014.01.007 · Cited by 124
Myoelectrically controlled wrist robot for stroke rehabilitation
Song, R., Tong, R. K., Hu, X., & Zhou, W. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-52 · Cited by 117
Self-citationSong, R., & Tong, R. K. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344728 · Cited by 83
Self-citationLiarokapis, M. V., Artemiadis, P., Kyriakopoulos, K. J., & Manolakos, E. S. (2013) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2013.2259594 · Cited by 67
Koo, T. K. K., Mak, A. F. T., & Hung, L. K. (2002) · Clinical Biomechanics · doi:10.1016/s0268-0033(02)00031-1 · Cited by 62
A real-time EMG-driven musculoskeletal model of the ankle
MANAL, K. T., Silbernagel, K. G., & Buchanan, T. S. (2011) · Multibody System Dynamics · doi:10.1007/s11044-011-9285-4 · Cited by 60
Simulation of distal tendon transfer of the biceps brachii and the brachialis muscles
Giat, Y., Mizrahi, J., Levine, W. S., & Chen, J. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90217-8 · Cited by 49
Electromechanical delay in biceps brachii assessed by ultrafast ultrasonography
Hug, F., Gallot, T., Catheline, S., & Nordez, A. (2011) · Muscle & Nerve · doi:10.1002/mus.21948 · Cited by 44
Huijing, P. A., & Baan, G. C. (1992) · Journal of Electromyography and Kinesiology · doi:10.1016/1050-6411(92)90022-b · Cited by 24
Movement Stability Analysis of Surface Electromyography-Based Elbow Power Assistance
Kwon, S., Kim, Y., & Kim, J. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2295381 · Cited by 21
Cited by
Review of control strategies for lower-limb exoskeletons to assist gait
Baud, R., Manzoori, A. R., Ijspeert, A., & Bouri, M. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00906-3 · Cited by 381
A review of the key technologies for sEMG-based human-robot interaction systems
Li, K., Zhang, J., Wang, L., Zhang, M., Li, J., & Bao, S. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.102074 · Cited by 233
Furukawa, J.-I., & Morimoto, J. (2025) · npj Robotics · doi:10.1038/s44182-025-00033-4 · Cited by 3
Metadata
- Authors
- Ao, D., Song, R., & Gao, J.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2017-08
- Volume
- 25
- Issue
- 8
- Pages
- 1125-1134
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2467301443
- Cited by
- 166
- References
- 52
- FWCI
- 4.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.