A Benchmark Dataset for SSVEP-Based Brain–Computer Interfaces
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
This paper presents a benchmark steady-state visual evoked potential (SSVEP) dataset acquired with a 40-target brain- computer interface (BCI) speller. The dataset consists of 64-channel Electroencephalogram (EEG) data from 35 healthy subjects (8 experienced and 27 naïve) while they performed a cue-guided target selecting task. The virtual keyboard of the speller was composed of 40 visual flickers, which were coded using a joint frequency and phase modulation (JFPM) approach. The stimulation frequencies ranged from 8 Hz to 15.8 Hz with an interval of 0.2 Hz. The phase difference between two adjacent frequencies was . For each subject, the data included six blocks of 40 trials corresponding to all 40 flickers indicated by a visual cue in a random order. The stimulation duration in each trial was five seconds. The dataset can be used as a benchmark dataset to compare the methods for stimulus coding and target identification in SSVEP-based BCIs. Through offline simulation, the dataset can be used to design new system diagrams and evaluate their BCI performance without collecting any new data. The dataset also provides high-quality data for computational modeling of SSVEPs. The dataset is freely available fromhttp://bci.med.tsinghua.edu.cn/download.html.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371 · cited 1×
“The electrode file can be imported into EEGLAB [24] for topographic analysis using the topoplot() function.”
MethodBrainard, D. H. (1997) · Spatial Vision · doi:10.1163/156856897x00357 · Cited by 19,702
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 2×
“BRAIN–computer interfaces (BCIs) provide humans a new communication channel based on information coding and decoding with brain activities [1]–[3].”
BackgroundMethodBrain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875
Review of the BCI Competition IV
Tangermann, M., Müller, K.-R., Aertsen, A., Birbaumer, N., Braun, C., Brunner, C., Leeb, R., Mehring, C., Miller, K. J., Müller-Putz, G. R., et al. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00055 · Cited by 1,288 · cited 1×
“national BCI Competitions [4]–[7] provided a large variety of BCI datasets from leading research groups.”
BackgroundHerrmann, C. S. (2001) · Experimental Brain Research · doi:10.1007/s002210100682 · Cited by 1,080 · cited 1×
“3 illustrates the amplitude spectrum and SNR images as functions of stimulation frequency and response frequency [25].”
BackgroundSteady-state visually evoked potentials: Focus on essential paradigms and future perspectives
Vialatte, F.-B., Maurice, M., Dauwels, J., & Cichocki, A. (2010) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2009.11.005 · Cited by 1,066 · cited 1×
“Recently, steady-state visual evoked potentials (SSVEPs) have been widely used in visual BCIs due to advantages of high information transfer rate (ITR) and little user training [8], [9].”
High-speed spelling with a noninvasive brain–computer interface
Chen, X., Wang, Y., Nakanishi, M., Gao, X., Jung, T.-P., & Gao, S. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1508080112 · Cited by 969
Self-citationThe BCI competition III: validating alternative approaches to actual BCI problems
Blankertz, B., Muller, K.-R., Krusienski, D. J., Schalk, G., Wolpaw, J. R., Schlogl, A., Pfurtscheller, G., Millan, J. R., Schroder, M., & Birbaumer, N. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875642 · Cited by 927 · cited 1×
“For each file, the data loaded in MATLAB generate a 4-D matrix named “data” with dimensions of [64, 1500, 40, 6].”
MethodChen, X., Wang, Y., Gao, S., Jung, T.-P., & Gao, X. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/4/046008 · Cited by 805
Self-citationBin, G., Gao, X., Yan, Z., Hong, B., & Gao, S. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/046002 · Cited by 773
Self-citationBlankertz, B., Muller, K.-R., Curio, G., Vaughan, T. M., Schalk, G., Wolpaw, J. R., Schlogl, A., Neuper, C., Pfurtscheller, G., Hinterberger, T., et al. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826692 · Cited by 670
Multiple Channel Detection of Steady-State Visual Evoked Potentials for Brain-Computer Interfaces
Friman, O., Volosyak, I., & Graser, A. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889160 · Cited by 541
Visual and Auditory Brain–Computer Interfaces
Gao, S., Wang, Y., Gao, X., & Hong, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2300164 · Cited by 449
Self-citationBrain-Computer Interfaces Based on Visual Evoked Potentials
Wang, Y., Gao, X., Hong, B., Jia, C., & Gao, S. (2008) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2008.923958 · Cited by 423 · cited 2×
“Recently, steady-state visual evoked potentials (SSVEPs) have been widely used in visual BCIs due to advantages of high information transfer rate (ITR) and little user training [8], [9].”
BackgroundSelf-citationSteady-State VEP-Based Brain-Computer Interface Control in an Immersive 3D Gaming Environment
Lalor, E. C., Kelly, S. P., Finucane, C., Burke, R., Smith, R., Reilly, R. B., & McDarby, G. (2005) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/asp.2005.3156 · Cited by 421
FREQUENCY RECOGNITION IN SSVEP-BASED BCI USING MULTISET CANONICAL CORRELATION ANALYSIS
ZHANG, Y., ZHOU, G., JIN, J., WANG, X., & CICHOCKI, A. (2014) · International Journal of Neural Systems · doi:10.1142/s0129065714500130 · Cited by 357
A high-ITR SSVEP-based BCI speller
Chen, X., Chen, Z., Gao, S., & Gao, X. (2014) · Brain-Computer Interfaces · doi:10.1080/2326263x.2014.944469 · Cited by 301
Self-citationFrequency recognition in SSVEP-based BCI using multiset canonical correlation analysisPreprint
Zhang, Y., Zhou, G., Jin, J., Wang, X., & Cichocki, A. S. (2014) · Cited by 264
Towards Zero Training for Brain-Computer Interfacing
Krauledat, M., Tangermann, M., Blankertz, B., & Müller, K.-R. (2008) · PLoS ONE · doi:10.1371/journal.pone.0002967 · Cited by 249
Multivariate synchronization index for frequency recognition of SSVEP-based brain–computer interface
Zhang, Y., Xu, P., Cheng, K., & Yao, D. (2014) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2013.07.018 · Cited by 233
A novel hybrid BCI speller based on the incorporation of SSVEP into the P300 paradigm
Yin, E., Zhou, Z., Jiang, J., Chen, F., Liu, Y., & Hu, D. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026012 · Cited by 225
Electrophysiological evidence for an early attentional mechanism in visual processing in humans
Di Russo, F., & Spinelli, D. (1999) · Vision Research · doi:10.1016/s0042-6989(99)00031-0 · Cited by 184
A new hybrid BCI paradigm based on P300 and SSVEP
Wang, M., Daly, I. P., Allison, B. Z., Jin, J., Zhang, Y., Chen, L., & Wang, X. (2014) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.06.003 · Cited by 160
Yuan, P., Chen, X., Wang, Y., Gao, X., & Gao, S. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/4/046006 · Cited by 146
Self-citationEye-gaze independent EEG-based brain–computer interfaces for communication
Riccio, A., Mattia, D., Simione, L., Olivetti, M., & Cincotti, F. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/4/045001 · Cited by 141
Sajda, P., Gerson, A., Muller, K.-R., Blankertz, B., & Parra, L. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814453 · Cited by 139 · cited 1×
“national BCI Competitions [4]–[7] provided a large variety of BCI datasets from leading research groups.”
BackgroundManyakov, N. V., Chumerin, N., Robben, A., Combaz, A., van Vliet, M., & Hulle, M. M. V. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036011 · Cited by 126
Li, Y., Pan, J., Long, J., Yu, T., Wang, F., Yu, Z., & Wu, W. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2469106 · Cited by 117 · cited 1×
“, P300) have become more and more popular in recent studies [10]–[13].”
BackgroundA visual parallel-BCI speller based on the time–frequency coding strategy
Xu, M., Chen, L., Zhang, L., Qi, H., Ma, L., Tang, J., Wan, B., & Ming, D. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026014 · Cited by 47
Cited by
EEG dataset and OpenBMI toolbox for three BCI paradigms: an investigation into BCI illiteracy
Lee, M.-H., Kwon, O.-Y., Kim, Y.-J., Kim, H.-K., Lee, Y.-E., Williamson, J., Fazli, S., & Lee, S.-W. (2019) · GigaScience · doi:10.1093/gigascience/giz002 · Cited by 590
Self-Supervised Learning for Electroencephalography
Rafiei, M. H., Gauthier, L. V., Adeli, H., & Takabi, D. (2024) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2022.3190448 · Cited by 317
Brain-Computer Interface: Advancement and Challenges
Mridha, M. F., Das, S. C., Kabir, M. M., Lima, A. A., Islam, M. R., & Watanobe, Y. (2021) · Sensors · doi:10.3390/s21175746 · Cited by 263
Liu, B., Chen, X., Shi, N., Wang, Y., Gao, S., & Gao, X. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2021.3114340 · Cited by 215
Self-citationBETA: A Large Benchmark Database Toward SSVEP-BCI Application
Liu, B., Huang, X., Wang, Y., Chen, X., & Gao, X. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00627 · Cited by 209
“As an extension of the benchmark database (Wang et al. (2017)), the number of target is 40 and the frequency range is also from 8 to 15.”
Self-citation
Metadata
- Authors
- Wang, Y., Chen, X., Gao, X., & Gao, S.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2017-10
- Volume
- 25
- Issue
- 10
- Pages
- 1746-1752
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2553904372
- Cited by
- 501
- References
- 30
- FWCI
- 8.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.