A Deep Transfer Learning Approach to Reducing the Effect of Electrode Shift in EMG Pattern Recognition-Based Control
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
An important barrier to commercialization of pattern recognition myoelectric control of prostheses is the lack of robustness to confounding factors such as electrode shift, skin impedance variations, and learning effects. To overcome this challenge, a novel supervised adaptation approach based on transfer learning (TL) with convolutional neural networks (CNNs) is proposed which requires only a short training session (a few seconds for each class) to recalibrate the system. TL is proposed as a solution to the problem of insufficient calibration data due to short training times for both classification and regression-based control schemes. This approach was validated for electrode shift of roughly 2.5cm with 13 able-bodied subjects to estimate individual and combined wrist motions. With this method, the original CNN (trained before the shift) was fine-tuned with the calibration data from after shifting. The results show that the proposed technique outperforms training a CNN from scratch (random initialization of weights) or a support vector machine (SVM) using the minimal calibration data. Moreover, it demonstrates superior performance than previous LDA and QDA-based adaptation approaches. As the outcomes confirm, the proposed CNN TL method provides a practical solution for adaptation to external factors, improving the robustness of electromyogram (EMG) pattern recognition systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LIBSVM: A library for support vector machines
Chang, C.-C., & Lin, C.-J. (2011) · ACM Transactions on Intelligent Systems and Technology · doi:10.1145/1961189.1961199 · Cited by 40,918 · cited 1×
“The libsvm [30] package in Matlab was exploited for SVM simulation.”
Rethinking the Inception Architecture for Computer Vision
Szegedy, C., Vanhoucke, V., Ioffe, S., Shlens, J., & Wojna, Z. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.308 · Cited by 32,138
How transferable are features in deep neural networks?
Yosinski, J., Clune, J., Bengio, Y., & Lipson, H. (2014) · arXiv · doi:10.48550/arxiv.1411.1792 · Cited by 6,061 · cited 5×
“In other words, a model developed for one task is reused as the starting point for a model on a second task [17].”
InfluentialLearning Transferable Features with Deep Adaptation Networks
Long, M., Cao, Y., Wang, J., & Jordan, M. I. (2015) · arXiv · doi:10.48550/arxiv.1502.02791 · Cited by 4,505 · cited 3×
“The first convolution layers are often expected to be more relevant for parameter transferring [17], [31].”
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 1×
“Five features including the TD set [29] and mean frequency were extracted from EMG windows, and were used as inputs to SVM models,”
Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992 · cited 1×
“PATTERN recognition myoelectric control has shown great potential in decoding motor intent in multiple degrees of freedom (DoFs) [1].”
Scheme, E., & Englehart, K. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0177 · Cited by 969 · cited 4×
“Due to the unpredictable nature of external factors, adaptation of a classifier/regressor is challenging, as the system must realize when and how to adapt [2].”
InfluentialSelf-citationDeep Learning for Electromyographic Hand Gesture Signal Classification Using Transfer Learning
Cote-Allard, U., Fall, C. L., Drouin, A., Campeau-Lecours, A., Gosselin, C., Glette, K., Laviolette, F., & Gosselin, B. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2896269 · Cited by 738 · cited 3×
“[19], [23], the present study aims to apply TL to overcome performance degradation due to confounding factors.”
Atzori, M., Cognolato, M., & Müller, H. (2016) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2016.00009 · Cited by 684 · cited 2×
“CNNs have been successfully applied for amputee subjects in offline tests [18].”
Surface EMG-Based Inter-Session Gesture Recognition Enhanced by Deep Domain Adaptation
Du, Y., Jin, W., Wei, W., Hu, Y., & Geng, W. (2017) · Sensors · doi:10.3390/s17030458 · Cited by 363
Feature Extraction and Selection for Myoelectric Control Based on Wearable EMG Sensors
Phinyomark, A., N. Khushaba, R., & Scheme, E. (2018) · Sensors · doi:10.3390/s18051615 · Cited by 352 · cited 1×
“It has been demonstrated [37] that a mixture of both temporal and spectral features are required for accurate recognition of motion estimation from the EMG signal.”
Self-citationYoung, A. J., Hargrove, L. J., & Kuiken, T. A. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2159216 · Cited by 287 · cited 1×
“Furthermore, the typical electrode shift in prostheses is reported to be less than 1 cm [34].”
Hargrove, L., Englehart, K., & Hudgins, B. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.11.005 · Cited by 276 · cited 2×
“This solution has been applied to overcome the effect of electrode shift in [10], by including virtually all plausible displacement combinations in the training set.”
Self-citationEMG Pattern Recognition in the Era of Big Data and Deep Learning
Phinyomark, A., & Scheme, E. (2018) · Big Data and Cognitive Computing · doi:10.3390/bdcc2030021 · Cited by 272 · cited 1×
“A review can be found in [22].”
Self-citationHahne, J. M., Schweisfurth, M. A., Koppe, M., & Farina, D. (2018) · Science Robotics · doi:10.1126/scirobotics.aat3630 · Cited by 216 · cited 3×
“Furthermore, in [32], [33], the users were able to”
Self-Correcting Pattern Recognition System of Surface EMG Signals for Upper Limb Prosthesis Control
Amsuss, S., Goebel, P. M., Jiang, N., Graimann, B., Paredes, L., & Farina, D. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2296274 · Cited by 202 · cited 2×
“Although some success has been made with this approach [5]–[7], robust adaptation to larger changes such as in electrode shift has yet to be achieved.”
Stango, A., Negro, F., & Farina, D. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2366752 · Cited by 191 · cited 3×
“With this approach, a variogram (a statistical measure of spatial correlation between channels) has been implemented as an alternative to features extracted from individual EMG channels and yielded higher robustness to electrode shift [8].”
Muceli, S., Jiang, N., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2282898 · Cited by 172 · cited 2×
“Furthermore, in [32], [33], the users were able to”
Vidovic, M. M.-C., Hwang, H.-J., Amsuss, S., Hahne, J. M., Farina, D., & Muller, K.-R. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2492619 · Cited by 171 · cited 18×
“Moreover, domain adaptation of LDA and QDA classifiers introduced in previous studies [12], [13], [24] were investigated, and the proposed CNN TL”
InfluentialSupport Vector Regression for Improved Real-Time, Simultaneous Myoelectric Control
Ameri, A., Kamavuako, E. N., Scheme, E. J., Englehart, K. B., & Parker, P. A. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2323576 · Cited by 171 · cited 1×
“included for comparison as previous work has shown their strong performance in myoelectric control [27].”
Self-citationRegression convolutional neural network for improved simultaneous EMG control
Ameri, A., Akhaee, M. A., Scheme, E., & Englehart, K. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab0e2e · Cited by 170 · cited 4×
“2) SVM-Based Schemes: The same SVM configuration as previously reported in [20], [21] was used.”
InfluentialSelf-citationIs it Finger or Wrist Dexterity That is Missing in Current Hand Prostheses?
Montagnani, F., Controzzi, M., & Cipriani, C. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2398112 · Cited by 161 · cited 2×
“Wrist motions were studied in this work because of their importance in upper-limb motor tasks [25].”
The effect of electrode displacements on pattern recognition based myoelectric control
Hargrove, L., Englehart, K., & Hudgins, B. (2006) · 2006 International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2006.260681 · Cited by 135 · cited 2×
“that, for a system with four EMG channels placed around the forearm and ten motion classes, a shift of 1 cm increases the classification error from roughly 5 to 20 percent (for longitudinal shift) and to 40 percent (for transverse shift) [3].”
Self-citationGu, Y.-K., Yang, D.-P., Huang, Q., Yang, W., & Liu, H. (2018) · Expert systems with applications · doi:10.1016/j.eswa.2017.11.049 · Cited by 128 · cited 2×
“Although some success has been made with this approach [5]–[7], robust adaptation to larger changes such as in electrode shift has yet to be achieved.”
Surface Electromyography (EMG) Signal Processing, Classification, and Practical Considerations
Phinyomark, A., Campbell, E., & Scheme, E. (2019) · Series in bioengineering · doi:10.1007/978-981-13-9097-5_1 · Cited by 101 · cited 1×
“Many other issues such as variations in limb position, changes in skin-electrode impedance (caused by dryness, humidity), fatigue, variations in muscle size, and learning effects as the user gains experience contracting his/her remnant muscles, degrade the accuracy of EMG-based movement intent estimation [2], [4].”
Self-citationReal-time, simultaneous myoelectric control using a convolutional neural network
Ameri, A., Akhaee, M. A., Scheme, E., & Englehart, K. B. (2018) · PLoS ONE · doi:10.1371/journal.pone.0203835 · Cited by 94 · cited 3×
“For classification, the same model structure was employed as in our previous work [20].”
Self-citationReduced Daily Recalibration of Myoelectric Prosthesis Classifiers Based on Domain Adaptation
Liu, J., Sheng, X., Zhang, D., He, J., & Zhu, X. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2380454 · Cited by 84 · cited 5×
“Moreover, domain adaptation of LDA and QDA classifiers introduced in previous studies [12], [13], [24] were investigated, and the proposed CNN TL”
InfluentialCounteracting Electrode Shifts in Upper-Limb Prosthesis Control via Transfer Learning
Prahm, C., Schulz, A., Paaben, B., Schoisswohl, J., Kaniušas, E., Dorffner, G., Hammer, B., & Aszmann, O. C. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2907200 · Cited by 72 · cited 5×
“4) Linear Compensation Transfer Learning (LCTL): The method proposed in [15], [16] was also conducted, which is based on the assumption that pre-shift EMG features can be derived from the post-shift features using a linear trans-”
InfluentialCascaded Adaptation Framework for Fast Calibration of Myoelectric Control
Zhu, X., Liu, J., Zhang, D., Sheng, X., & Jiang, N. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2562180 · Cited by 51 · cited 5×
“Moreover, domain adaptation of LDA and QDA classifiers introduced in previous studies [12], [13], [24] were investigated, and the proposed CNN TL”
InfluentialWang, W., Chen, B., Xia, P., Hu, J., & Peng, Y. (2018) · Artificial Organs · doi:10.1111/aor.13153 · Cited by 47 · cited 3×
“Furthermore in [23], a recurrent CNN model was trained on data from multiple”
Simple and Fast Compensation of sEMG Interface Rotation for Robust Hand Motion Recognition
Kim, M., Kim, K., & Chung, W. K. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2878439 · Cited by 43 · cited 1×
“Moreover, in other applications, such as teleoperation, electrode shift can be more severe due to the lack of user-specific sockets [35].”
Transfer Learning for Rapid Re-calibration of a Myoelectric Prosthesis After Electrode Shift
Prahm, C., Paaßen, B., Schulz, A., Hammer, B., & Aszmann, O. C. (2016) · Biosystems & biorobotics · doi:10.1007/978-3-319-46669-9_28 · Cited by 42 · cited 5×
“4) Linear Compensation Transfer Learning (LCTL): The method proposed in [15], [16] was also conducted, which is based on the assumption that pre-shift EMG features can be derived from the post-shift features using a linear trans-”
InfluentialScheme, E., & Englehart, K. B. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6943675 · Cited by 41 · cited 1×
“A second strategy is to identify and deploy EMG features robust to external factors [8], [9].”
Self-citationReal-time, simultaneous myoelectric control using visual target-based training paradigm
Ameri, A., Kamavuako, E. N., Scheme, E., Englehart, K. B., & Parker, P. A. (2014) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2014.03.006 · Cited by 41 · cited 2×
“approach [26] was adopted where the regression target was set to the normalized position of the progress bar.”
Self-citationExpectation maximization transfer learning and its application for bionic hand prostheses
Paaßen, B., Schulz, A., Hahne, J. M., & Hammer, B. (2018) · Neurocomputing · doi:10.1016/j.neucom.2017.11.072 · Cited by 32 · cited 1×
“Moreover, in [14]–[16], recalibra-”
Cited by
Deep Learning for EMG-based Human-Machine Interaction: A Review
Xiong, D., Zhang, D., Zhao, X., & Zhao, Y. (2021) · IEEE/CAA Journal of Automatica Sinica · doi:10.1109/jas.2021.1003865 · Cited by 395
Leveraging High-Density EMG to Investigate Bipolar Electrode Placement for Gait Prediction Models
Hodossy, B. K., Guez, A. S., Jing, S., Huo, W., Vaidyanathan, R., & Farina, D. (2024) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2024.3371099 · Cited by 10
Metadata
- Authors
- Ameri, A., Akhaee, M. A., Scheme, E., & Englehart, K.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2020-02
- Volume
- 28
- Issue
- 2
- Pages
- 370-379
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2997304337
- Cited by
- 171
- References
- 35
- FWCI
- 4.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.