An Isolated Three-Port Bidirectional DC-DC Converter With Decoupled Power Flow Management
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
An isolated three-port bidirectional dc-dc converter composed of three full-bridge cells and a high-frequency transformer is proposed in this paper. Besides the phase shift control managing the power flow between the ports, utilization of the duty cycle control for optimizing the system behavior is discussed and the control laws ensuring the minimum overall system losses are studied. Furthermore, the dynamic analysis and associated control design are presented. A control-oriented converter model is developed and the Bode plots of the control-output transfer functions are given. A control strategy with the decoupled power flow management is implemented to obtain fast dynamic response. Finally, a 1.5 kW prototype has been built to verify all theoretical considerations. The proposed topology and control is particularly relevant to multiple voltage electrical systems in hybrid electric vehicles and renewable energy generation systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fundamentals of Power Electronics
Erickson, R. W., & Maksimović, D. (2001) · Springer eBooks · doi:10.1007/b100747 · Cited by 6,112
Fundamentals of Power Electronics
Erickson, R. W., & Maksimović, D. (2020) · Springer eBooks · doi:10.1007/978-3-030-43881-4 · Cited by 5,420
A three-phase soft-switched high-power-density DC/DC converter for high-power applications
De Doncker, R. W. A. A., Divan, D. M., & Kheraluwala, M. H. (1991) · IEEE Transactions on Industry Applications · doi:10.1109/28.67533 · Cited by 2,535
Energy Storage and Its Use With Intermittent Renewable Energy
Barton, J. P., & Infield, D. G. (2004) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2003.822305 · Cited by 1,388
Batteries and Ultracapacitors for Electric, Hybrid, and Fuel Cell Vehicles
Burke, A. F. (2007) · Proceedings of the IEEE · doi:10.1109/jproc.2007.892490 · Cited by 791
Simplified analysis of PWM converters using model of PWM switch. II. Discontinuous conduction mode
Vorperian, V. (1990) · IEEE Transactions on Aerospace and Electronic Systems · doi:10.1109/7.106127 · Cited by 787
A new ZVS bidirectional DC-DC converter for fuel cell and battery application
Peng, F. Z., Li, H., Su, G.-J., & Lawler, J. S. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.820550 · Cited by 782 · cited 1×
“A converter topology, viewed as an extension of the boost-dual-half bridge topology [21], has been described in [10].”
BackgroundThree-Port Bidirectional Converter for Hybrid Fuel Cell Systems
Duarte, J. L., Hendrix, M., & Simoes, M. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.889928 · Cited by 441
Characteristics of the Multiple-Input DC–DC Converter
Matsuo, H., Lin, W., Kurokawa, F., Shigemizu, T., & Watanabe, N. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2004.825362 · Cited by 385
Multi-input DC/DC converter based on the multiwinding transformer for renewable energy applications
Chen, Y.-M., Liu, Y.-C., & Wu, F.-Y. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2002.800776 · Cited by 350
Cited by
Zhao, B., Song, Q., Liu, W., & Sun, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2289913 · Cited by 1,886
Zhao, B., Yu, Q., & Sun, W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2180928 · Cited by 932
“In some of these studies [21], [22], the duty ratio of the driving signals of each semiconductor device is variable, and should be calculated online, that increases the complexity of the control.”
BackgroundMethodGlobal Trends in High-Power On-Board Chargers for Electric Vehicles
Khaligh, A., & D'Antonio, M. (2019) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2019.2897050 · Cited by 652
“control algorithms have been previously studied in [129]–[131] for constant voltage and resistive loads; however, three-port power flow between three variable voltage sources is a chal-”
BackgroundGeneralized Average Modeling of Dual Active Bridge DC–DC Converter
Qin, H., & Kimball, J. W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2165734 · Cited by 557
Tan, N. M. L., Abe, T., & Akagi, H. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2108317 · Cited by 490
Topologies and Control Schemes of Bidirectional DC–DC Power Converters: An Overview
Gorji, S. A., Sahebi, H. G., Ektesabi, M., & Rad, A. B. (2019) · IEEE Access · doi:10.1109/access.2019.2937239 · Cited by 439
Review on Advanced Control Technologies for Bidirectional DC/DC Converters in DC Microgrids
Xu, Q., Vafamand, N., Chen, L., Dragicevic, T., Xie, L., & Blaabjerg, F. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.2978064 · Cited by 439
Review of Multiport Converters for Solar and Energy Storage Integration
Bhattacharjee, A. K., Kutkut, N., & Batarseh, I. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2830788 · Cited by 423
Modeling and Control of Three-Port DC/DC Converter Interface for Satellite Applications
Qian, Z., Abdel-Rahman, O., Al-Atrash, H., & Batarseh, I. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2033926 · Cited by 399
“Similarly, isolated-bidirectional multiport converters can also be constructed out of full-bridge topology for relatively high-power applications [19]–[23], since they apply full voltage to the transformer and adopt more switches to process power.”
BackgroundChakraborty, S., Vu, H.-N., Hasan, M. M., Tran, D.-D., Baghdadi, M. E., & Hegazy, O. (2019) · Energies · doi:10.3390/en12081569 · Cited by 384
Minimum-Current-Stress Scheme of Dual Active Bridge DC-DC Converter With Unified-phase-shift Control
Hou, N., Song, W., & wu, M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2521410 · Cited by 369
A high-efficiency grid-tie battery energy storage system
Qian, H., Zhang, J., Lai, J.-S., & Yu, W. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2096562 · Cited by 360
Solid-State Transformer Architecture Using AC–AC Dual-Active-Bridge Converter
Qin, H., & Kimball, J. W. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2204710 · Cited by 310
A High Step-Up Three-Port DC–DC Converter for Stand-Alone PV/Battery Power Systems
Chen, Y.-M., Huang, A. Q., & Yu, X. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2242491 · Cited by 305
Optimized Operation of Current-Fed Dual Active Bridge DC–DC Converter for PV Applications
Shi, Y., Li, R., Xue, Y., & Li, H. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2432093 · Cited by 298
Wang, Z., & Li, H. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2236580 · Cited by 230
A Single-Stage Microinverter Without Using Eletrolytic Capacitors
Hu, H., Harb, S., Kutkut, N. H., Shen, Z. J., & Batarseh, I. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2224886 · Cited by 227
“Many three-port converters have been proposed in recent years, where they can be tailored for singlephase inverters with one port dedicated for power decoupling function [19]–[23].”
BackgroundEnhanced Load Step Response for a Bidirectional DC–DC Converter
Segaran, D., Holmes, D. G., & McGrath, B. P. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2200505 · Cited by 219
“B IDIRECTIONAL power transfer is a core requirement for many emerging power electronic conversion applications, such as regenerative motor drives [1], plug-in hybrid electric vehicles (P-HEV), uninterruptible power supply (UPS) systems, and renewable energy applications with intermediate energy storage [2]–[7].”
BackgroundTopology Analysis and Review of Three-Port DC–DC Converters
Wang, Z., Luo, Q., Wei, Y., Mou, D., Lu, X., & Sun, P. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2985287 · Cited by 192
“12 shows that most of the fully isolated TPCs with “P1S2” and ”P1S3-II” structures have numerous switches due to the use of full-bridge converters except the ones proposed in [67], [75],”
BackgroundWen, H., Xiao, W., & Su, B. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2316229 · Cited by 179
Mangu, B., Akshatha, S., Suryanarayana, D., & Fernandes, B. G. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2016.2544789 · Cited by 174
Zhang, Z., Ouyang, Z., Thomsen, O. C., & Andersen, M. A. E. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2159515 · Cited by 166
Ali, A., H. H. Mousa, H., F. Shaaban, M., A. Azzouz, M., & S. A. Awad, A. (2024) · Journal of Modern Power Systems and Clean Energy · doi:10.35833/mpce.2023.000107 · Cited by 162
Dual-Transformer-Based Asymmetrical Triple-Port Active Bridge (DT-ATAB) Isolated DC–DC Converter
Jakka, V. N. S. R., Shukla, A., & Demetriades, G. D. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2674586 · Cited by 160
“A comparison study between the proposed DT-ATAB, TAB [7], and MP-CLL [18] converter topologies when they are used to supply a load power simultaneously from two different sources is presented in Table V.”
BackgroundMethodInfluentialNovel Modular Multiple-Input Bidirectional DC–DC Power Converter (MIPC) for HEV/FCV Application
Hintz, A., Prasanna, U. R., & Rajashekara, K. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2371778 · Cited by 158
“In [17], multiple sources are interfaced using a common highfrequency transformer, where each source is connected through full-bridge cells utilizing 12 switches for three sources.”
Rashidi, M., Altin, N. N., Ozdemir, S. S., Bani-Ahmed, A., & Nasiri, A. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2939741 · Cited by 90
“trains) [13]–[16], electrical vehicle power distribution systems [11], [17], [18], hybrid distributed generation (DG), and dc power distribution applications [10], [19]–[22].”
BackgroundInfluentialAkagi, H., Kinouchi, S.-I., & Miyazaki, Y. (2016) · CPSS Transactions on Power Electronics and Applications · doi:10.24295/cpsstpea.2016.00004 · Cited by 84
Modelling and ZVS control of an isolated three-phase bidirectional AC-DC converter
Jauch, F., & Biela, J. (2013) · 2013 15th European Conference on Power Electronics and Applications (EPE) · doi:10.1109/epe.2013.6634323 · Cited by 19
“First, the converter topology including the applied high-frequency transformer is presented.”
MethodBempah, K. O., Heo, K.-W., & Jung, J.-H. (2023) · Journal of Power Electronics · doi:10.1007/s43236-022-00528-5 · Cited by 15
Wang, Y., Taha, W., & Anand, A. (2025) · SAE Technical Paper Series · doi:10.4271/2025-01-8567 · Cited by 3
Metadata
- Authors
- Zhao, C., Round, S. D., & Kolar, J. W.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2008-09
- Volume
- 23
- Issue
- 5
- Pages
- 2443-2453
- ISSN
- 0885-8993 (ISSN-L)
- OpenAlex
- W2110938228
- Cited by
- 900
- References
- 21
- FWCI
- 16.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.