Design-Oriented Transient Stability Analysis of PLL-Synchronized Voltage-Source Converters
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Differing from synchronous generators, there are lack of physical laws governing the synchronization dynamics of voltage-source converters (VSCs). The widely used phase-locked loop (PLL) plays a critical role in maintaining the synchronism of current-controlled VSCs, whose dynamics are highly affected by the power exchange between VSCs and the grid. This article presents a design-oriented analysis on the transient stability of PLL-synchronized VSCs, i.e., the synchronization stability of VSCs under large disturbances, by employing the phase portrait approach. Insights into the stabilizing effects of the first- and second-order PLLs are provided with the quantitative analysis. It is revealed that simply increasing the damping ratio of the second-order PLL may fail to stabilize VSCs during severe grid faults, whereas the first-order PLL can always guarantee the transient stability of VSCs when equilibrium operation points exist. An adaptive PLL that switches between the second-order and the first-order PLL during the fault-occurring/-clearing transient is proposed for preserving both the transient stability and the phase-tracking accuracy. Time-domain simulations and experimental tests, considering both the grid fault and the fault recovery, are performed, and the obtained results validate the theoretical findings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
Nonlinear Dynamics and Chaos: With Applications to Physics, Biology, Chemistry, and Engineering
Strogatz, S., Friedman, M., Mallinckrodt, A. J., & McKay, S. (1994) · Computers in Physics · doi:10.1063/1.4823332 · Cited by 4,648
Grid Converters for Photovoltaic and Wind Power Systems
Teodorescu, R., Liserre, M., & Rodríguez, P. (2011) · Wiley eBooks · doi:10.1002/9780470667057 · Cited by 3,344
Gardner, F. M. (2005) · Wiley eBooks · doi:10.1002/0471732699 · Cited by 1,692
Decoupled Double Synchronous Reference Frame PLL for Power Converters Control
Rodriguez, P., Pou, J., Bergas, J., Candela, J. I., Burgos, R. P., & Boroyevich, D. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890000 · Cited by 1,359
Analysis of D-Q Small-Signal Impedance of Grid-Tied Inverters
Wen, B., Boroyevich, D., Burgos, R., Mattavelli, P., & Shen, Z. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2398192 · Cited by 1,334
Harmonic Stability in Power Electronic-Based Power Systems: Concept, Modeling, and Analysis
Wang, X., & Blaabjerg, F. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2812712 · Cited by 1,282
Self-citationA phase tracking system for three phase utility interface inverters
Chung, S.-K. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.844502 · Cited by 1,192
Input-Admittance Calculation and Shaping for Controlled Voltage-Source Converters
Harnefors, L., Bongiorno, M., & Lundberg, S. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.904022 · Cited by 1,117
Rodriguez, P., Luna, A., Candela, I., Mujal, R., Teodorescu, R., & Blaabjerg, F. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2042420 · Cited by 1,112
Dong, D., Wen, B., Boroyevich, D., Mattavelli, P., & Xue, Y. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2334665 · Cited by 709
Rodríguez, P., Luna, A., Muñoz-Aguilar, R. S., Etxeberria-Otadui, I., Teodorescu, R., & Blaabjerg, F. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2159242 · Cited by 681
Passivity-Based Stability Assessment of Grid-Connected VSCs—An Overview
Harnefors, L., Wang, X., Yepes, A. G., & Blaabjerg, F. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2015.2490549 · Cited by 674
Self-citationDistributed Power-Generation Systems and Protection
Blaabjerg, F., Yang, Y., Yang, D., & Wang, X. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2696878 · Cited by 671
Self-citationGuo, X., Wu, W., & Chen, Z. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2041738 · Cited by 475
Taul, M. G., Wang, X., Davari, P., & Blaabjerg, F. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2892142 · Cited by 415
Self-citationLarge Signal Synchronizing Instability of PLL-Based VSC Connected to Weak AC Grid
Hu, Q., Fu, L., Ma, F., & Ji, F. (2019) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2019.2892224 · Cited by 398
Wu, H., & Wang, X. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2875669 · Cited by 320
Self-citationGrid Synchronization PLL Based on Cascaded Delayed Signal Cancellation
Wang, Y. F., & Li, Y. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2099669 · Cited by 312
Grid-Synchronization Stability Improvement of Large Scale Wind Farm During Severe Grid Fault
Ma, S., Geng, H., Liu, L., Yang, G., & Pal, B. C. (2018) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2017.2700050 · Cited by 261
Problems of Startup and Phase Jumps in PLL Systems
Ghartemani, M. K., Khajehoddin, S. A., Jain, P. K., & Bakhshai, A. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2169089 · Cited by 233
Phase-Locked Loop Noise Reduction via Phase Detector Implementation for Single-Phase Systems
Thacker, T., Boroyevich, D., Burgos, R., & Wang, F. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2069070 · Cited by 192
Cited by
Grid-Forming Converters: Control Approaches, Grid-Synchronization, and Future Trends—A Review
Rosso, R., Wang, X., Liserre, M., Lu, X., & Engelken, S. (2021) · IEEE Open Journal of Industry Applications · doi:10.1109/ojia.2021.3074028 · Cited by 1,187
Self-citationGrid-Synchronization Stability of Converter-Based Resources—An Overview
Wang, X., Taul, M. G., Wu, H., Liao, Y., Blaabjerg, F., & Harnefors, L. (2020) · IEEE Open Journal of Industry Applications · doi:10.1109/ojia.2020.3020392 · Cited by 862
Self-citationTransient Stability of Voltage-Source Converters With Grid-Forming Control: A Design-Oriented Study
Pan, D., Wang, X., Liu, F., & Shi, R. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2946310 · Cited by 681
Self-citationA Review of Current-Limiting Control of Grid-Forming Inverters Under Symmetrical Disturbances
Fan, B., Liu, T., Zhao, F., Wu, H., & Wang, X. (2022) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2022.3227507 · Cited by 371
“However, the PLL can suffer from small-signal or transient instability issues under weak grid conditions [46], [47].”
BackgroundSelf-citationWu, H., & Wang, X. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.2976791 · Cited by 227
Self-citation
Metadata
- Authors
- Wu, H., & Wang, X.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2020-04
- Volume
- 35
- Issue
- 4
- Pages
- 3573-3589
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2970988154
- Cited by
- 454
- References
- 22
- FWCI
- 22.76
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.