Reduced Switching-Frequency Modulation and Circulating Current Suppression for Modular Multilevel Converters
The DOI matches its Crossref record; 21 of the 22 references it cites were found in a registry or an index.
Abstract
This paper describes a modified phase-shifted carrier-based pulsewidth-modulation (PSC-PWM) scheme for modular multilevel converters (MMC). In order to reduce the average device switching frequency, a reduced switching-frequency (RSF) voltage balancing algorithm is developed. This paper also proposes a circulating current suppressing controller (CCSC) to minimize the inner circulating current in an MMC. Based on the double line-frequency, negative-sequence rotational frame, the three-phase alternative circulating currents are decomposed into two dc components and are minimized by a pair of proportional integral controllers. Simulation results based on a detailed PSCAD/EMTDC model prove the effectiveness of the modified PSC-PWM method and the RSF voltage-balancing algorithm. The proposed CCSC not only eliminates the inner circulating current but also improves the quality of the converter ac output voltage. A simple loss evaluation demonstrates that the RSF voltage-balancing algorithm and the CCSC reduce the converter power losses.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
An innovative modular multilevel converter topology suitable for a wide power range
Lesnicar, A., & Marquardt, R. (2004) · 2003 IEEE Bologna Power Tech Conference Proceedings, · doi:10.1109/ptc.2003.1304403 · Cited by 2,908 · cited 1×
“Basic concepts and operation principles of MMC were studied in [7]–[10].”
BackgroundControl and Experiment of Pulsewidth-Modulated Modular Multilevel Converters
Hagiwara, M., & Akagi, H. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2014236 · Cited by 1,565 · cited 2×
“Reference [ 5 ] applied the PWM scheme to MMC with averaging and balancing controls and the results were verified by simulations and experiments.”
BackgroundMethodDynamic Performance of a Modular Multilevel Back-to-Back HVDC System
Saeedifard, M., & Iravani, R. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2050787 · Cited by 1,188 · cited 1×
“a back-to-back MMC-HVDC under balanced and unbalanced conditions are investigated in [17].”
Modulation, Losses, and Semiconductor Requirements of Modular Multilevel Converters
Rohner, S., Bernet, S., Hiller, M., & Sommer, R. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2031187 · Cited by 934 · cited 5×
“The voltage-balancing algorithm, by sorting the capacitors’ voltages, is proposed in [9], [12].”
MethodInfluentialA new mathematical model and control of a three-phase AC-DC voltage source converter
Blasko, V., & Kaura, V. (1997) · IEEE Transactions on Power Electronics · doi:10.1109/63.554176 · Cited by 871
On dynamics and voltage control of the Modular Multilevel Converter
Antonopoulos, A., Ängquist, L., & Nee, H. (2009) · European Conference on Power Electronics and Applications · Cited by 831
New transformerless, scalable Modular Multilevel Converters for HVDC-transmission
Allebrod, S., Hamerski, R., & Marquardt, R. (2008) · 2008 IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2008.4591920 · Cited by 785
A New AC/AC Multilevel Converter Family
Glinka, M., & Marquardt, R. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.843973 · Cited by 772 · cited 3×
“11(b) uses the modified PSC-PWM method with the conventional voltage-balancing algorithm proposed in [9] and [12] whereas Fig.”
MethodGnanarathna, U. N., Gole, A. M., & Jayasinghe, R. P. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2060737 · Cited by 739
Control and Performance of a Transformerless Cascade PWM STATCOM With Star Configuration
Akagi, H., Inoue, S., & Yoshii, T. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2007.900487 · Cited by 643 · cited 1×
“topology in STATCOM applications [4], the amount of the capacitors is doubled in MMC, since it uses the half H-bridge submodules.”
Method
Research works printed but not linked: 7
- backlund, 2004, Data sheet IGBT module 5SNA 1200E250100
- backlund, 2009, Application note Applying IGBTs
- 2001, Stromrichterschaltungen mit verteilten Energiespeichern
- dorn, 2007, Novel voltage-sourced converters for HVDC and FACTS applications, CIGRE Symp
- lesnicar, 2008, Neuartiger modularer mehrpunktumrichter M2C fr netzkupplungsanwendungen
- 2005, VSC transmission
- 2008, Drive for a phase module branch of a multilevel converter
Cited by
Items 101–200 of 1,000
Coordination of MMCs With Hybrid DC Circuit Breakers for HVDC Grid Protection
Wang, S., Li, C., Adeuyi, O. D., Li, G., Ugalde‐Loo, C. E., & Liang, J. (2018) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2018.2828705 · Cited by 118
Optimized Control Strategy Based on Dynamic Redundancy for the Modular Multilevel Converter
Liu, G., Xu, Z. G., Xue, Y., & Tang, G. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2305663 · Cited by 115
“reduced switching-frequency voltage balancing algorithm [22] is applied.”
BackgroundMethodSelf-citationEnhanced Independent Pole Control of Hybrid MMC-HVdc System
Xiang, W., Lin, W., Xu, L., & Wen, J. (2017) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2017.2715040 · Cited by 112
Self-citationDeng, F., & Chen, Z. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2388195 · Cited by 107
“The circulating current elimination control in [11] is used here.”
BackgroundMethodResultInfluentialA New Circuit Performance of Modular Multilevel Inverter Suitable for Photovoltaic Conversion Plants
Nademi, H., Das, A., Burgos, R. P., & Norum, L. E. (2015) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2015.2509599 · Cited by 110
DC Line Fault Identification Based on Pulse Injection From Hybrid HVDC Breaker
Song, G., Wang, T., & Hussain, K. S. T. (2018) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2018.2865226 · Cited by 107
Self-Start Control With Grouping Sequentially Precharge for the C-MMC-Based HVDC System
Xue, Y., Xu, Z. G., & Tang, G. (2013) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2013.2279106 · Cited by 111
Self-citationBeyond the MMC: Extended Modular Multilevel Converter Topologies and Applications
Sun, P., Tian, Y., Pou, J., & Konstantinou, G. S. (2022) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2022.3175714 · Cited by 108
Dynamic Analysis of MMC-Based MTDC Grids: Use of MMC Energy to Improve Voltage Behavior
Freytes, J., Akkari, S., Rault, P., Belhaouane, M. M., Gruson, F., Colas, F., & Guillaud, X. (2018) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2018.2868878 · Cited by 103
“In the EMT Simulation model used as a reference, the MMCs are modeled with the switching “Model #2: Equivalent Circuit-Based Model” with 400 submodules per arm from [19] and the reduced switching-frequency capacitor balancing algorithm from [24].”
MethodA Coherency-Based Equivalence Method for MMC Inverters Using Virtual Synchronous Generator Control
Li, C., Xu, J., & Zhao, C. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2499262 · Cited by 106
“commonly used nearest level control (NLC) based modulation and capacitor voltage balancing method [23], [24].”
MethodCirculating Current Suppression for MMC-HVDC under Unbalanced Grid Conditions
Wang, J., Liang, J., Wang, C., & Dong, X. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2017.2675992 · Cited by 105
Cisneros, R., Pirro, M., Bergna‐Diaz, G., Ortega, R. S., Ippoliti, G., & Molinas, M. (2015) · Control Engineering Practice · doi:10.1016/j.conengprac.2015.07.002 · Cited by 106
Modular Multilevel Converter With an Adaptive Observer of Capacitor Voltages
Nademi, H., Das, A., & Norum, L. E. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2301879 · Cited by 105
“The study in [17] presented the modified PS-PWM approach to reduce the average device switching frequency by developing a voltage balancing algorithm.”
MethodBergna-Diaz, G., Freytes, J., Guillaud, X., D'Arco, S., & Suul, J. A. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2793159 · Cited by 100
Li, W., Grégoire, L.-A., & Bélanger, J. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2362879 · Cited by 103
“The generated pulses are reassigned to SMs according to the sorting results of the capacitor voltage and valve current direction [8], [15]–[22], [25]–[28], [32].”
MethodImpedance Analysis of Modular Multi-Level Converters Connected to Weak AC Grids
Khazaei, J., Beza, M., & Bongiorno, M. (2017) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2017.2779403 · Cited by 101
Abushafa, O., Dahidah, M., Gadoue, S. M., & Atkinson, D. J. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2795519 · Cited by 102
A Prototype of Modular Multilevel Converters
Zhou, Y., Jiang, D., Hu, P., Guo, J., Liang, Y., & Lin, Z. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2278338 · Cited by 106
“Therefore, the switching frequency of each power semiconductor switch is still very high, causing more power losses [17].”
BackgroundMethodPérez-Basante, A., Ceballos, S., Konstantinou, G. S., Pou, J., Andreu, J., & de Alegría, I. M. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2666847 · Cited by 104
“For simplification, the junction temperature and the current factor are Tj = 125 ◦C and k = 1, respectively [30].”
BackgroundMethodPan, J., Ke, Z., Sabbagh, M. A., Li, H., Potty, K. A., Perdikakis, W., Na, R., Zhang, J., Wang, J., & Xu, L. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2978657 · Cited by 98
Self-citationLoss Optimization of MMC by Second-Order Harmonic Circulating Current Injection
Yang, L., Li, Y., Li, Z., Wang, P., Xu, S., & Gou, R. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2751068 · Cited by 97
“ulation (PWM) [17], [18] and nearest level modulation (NLM) [8], [19]–[22].”
BackgroundMethodA LCC and MMC hybrid HVDC topology with DC line fault clearance capability
Tang, G., & Xu, Z. G. (2014) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2014.04.045 · Cited by 101
Self-citationValve Losses Evaluation Based on Piecewise Analytical Method for MMC–HVDC Links
Zhang, Z., Xu, Z. G., & Xue, Y. (2014) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2014.2304724 · Cited by 96
Self-citationSelf-Synchronization of Wind Farm in an MMC-Based HVDC System: A Stability Investigation
Amin, M., Rygg, A., & Molinas, M. (2017) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2017.2661540 · Cited by 99
“The circulating current flowing in each phase consists of a dc component and low-order harmonic components, mainly the negative sequence component with the frequency twice the fundamental [48]–[50].”
BackgroundDC Fault Current Clearance at the Source Side of HVDC Grid Using Hybrid MMC
Xu, J., Zhao, X., Jing, H., Liang, J., & Zhao, C. (2019) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2019.2927234 · Cited by 95
Dual-Port Grid-Forming Control of MMCs and Its Applications to Grids of Grids
Groß, D., Sánchez‐Sánchez, E., Prieto‐Araujo, E., & Gomis‐Bellmunt, O. (2022) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2022.3157249 · Cited by 95
Analysis of the Performance of MMC Under Fault Conditions in HVDC-Based Offshore Wind Farms
Vidal-Albalate, R., Beltrán, H., Rolán, A., Belenguer, E., Pena, R. S., & Blasco-Giménez, R. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2468171 · Cited by 97
“A standard voltage balancing algorithm is used for the MMC [23].”
MethodAntónio-Ferreira, A., Collados‐Rodríguez, C., & Gomis‐Bellmunt, O. (2017) · Electric Power Systems Research · doi:10.1016/j.epsr.2017.08.015 · Cited by 100
An enhanced MMC topology with DC fault ride-through capability
Li, X., Liu, W., Song, Q., Rao, H., & Xu, S. (2013) · IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2013.6700152 · Cited by 92
“Modular design, low switching frequency, high efficiency, and excellent output voltage waveforms are also advantages of MMC [4]-[11].”
BackgroundGlasdam, J. B., Hjerrild, J., Kocewiak, Ł., & Bak, C. L. (2012) · International Conference on Power System Technology (POWERCON) · doi:10.1109/powercon.2012.6401377 · Cited by 102
Sliding Mode Control of the Modular Multilevel Converter
Yang, Q., Saeedifard, M., & Perez, M. A. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2818657 · Cited by 89
Wang, J., Tang, Y. K., Lin, P., Liu, X., & Pou, J. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2955485 · Cited by 92
Reliability Model of MMC Considering Periodic Preventive Maintenance
Wang, B., Wang, X., Bie, Z., Judge, P. D., Wang, X., & Green, T. C. (2016) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2016.2602888 · Cited by 92
Impedance-Based Stability Analysis of Voltage-Controlled MMCs Feeding Linear AC Systems
Wu, H., Wang, X., & Kocewiak, Ł. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2911654 · Cited by 88
Li, Y., Jones, E. A., & Wang, F. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2016.2617865 · Cited by 84
“The basic ideas of these methods are similar, and the method in [17] is considered in this paper.”
MethodVirtual Capacitor Control: Mitigation of DC Voltage Fluctuations in MMC-Based HVdc Systems
Shinoda, K., Benchaib, A., Dai, J., & Guillaud, X. (2017) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2017.2723939 · Cited by 94
Ronanki, D., & Williamson, S. S. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2912771 · Cited by 89
“This controller can be adopted with any type of modulation scheme such as phase-shifted PWM (PS-PWM) [37], phase-”
MethodInfluentialCapacitor Selection for Modular Multilevel Converter
Tang, Y., Ran, L., Alatise, O. M., & Mawby, P. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2533620 · Cited by 91
New Efficient Submodule for a Modular Multilevel Converter in Multiterminal HVDC Networks
Adam, G. P., Abdelsalam, I., Fletcher, J. E., Burt, G. M., Holliday, D., & Finney, S. J. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2603180 · Cited by 84
Yang, S., Wang, P., Tang, Y. K., Zagrodnik, M. A., Hu, X., & Tseng, K. J. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2017.2749257 · Cited by 90
Reference Submodule Based Capacitor Monitoring Strategy for Modular Multilevel Converters
Deng, F., Wang, Q., Liu, D., Wang, Y., Cheng, M., & Chen, Z. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2857832 · Cited by 84
An Optimized Circulating Current Control Method Based on PR and PI Controller for MMC Applications
Isik, S., Alharbi, M., & Bhattacharya, S. (2021) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2021.3092298 · Cited by 87
Offshore Wind Farm Modeling Accuracy and Efficiency in MMC-Based Multiterminal HVDC Connection
Karaagac, U., Mahseredjian, J., Cai, L., & Saad, H. (2016) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2016.2522562 · Cited by 87
“Circulating currents can be eliminated by using an active control over the modulated voltage [16], [19].”
BackgroundSelection methods of main circuit parameters for modular multilevel converters
Xu, Z. G., Xiao, H., & Zhang, Z. (2016) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2015.0434 · Cited by 89
Self-citationControl design of Modular Multilevel Converters in normal and AC fault conditions for HVDC grids
Prieto‐Araujo, E., Junyent‐Ferré, A., Collados‐Rodríguez, C., Clariana-Colet, G., & Gomis‐Bellmunt, O. (2017) · Electric Power Systems Research · doi:10.1016/j.epsr.2017.06.020 · Cited by 96
Arm Current Control Strategy for MMC-HVDC Under Unbalanced Conditions
Liang, Y., Liu, J., Zhang, T., & Yang, Q. (2017) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2016.2554620 · Cited by 81
“Reference [9] proposes a circulating current suppressing method in double line-frequency negative sequence rotational frame to eliminate negative-sequence second harmonic circulating current under balanced voltage conditions.”
MethodA Review of Modular Multilevel Converters for Stationary Applications
Wang, Y., Aksöz, A., Geury, T., Öztürk, S. B., Kıvanç, Ö. C., & Hegazy, O. (2020) · Applied Sciences · doi:10.3390/app10217719 · Cited by 92
Control of Circulating Currents in Modular Multilevel Converters Through Redundant Voltage Levels
Konstantinou, G., Pou, J., Ceballos, S., Picas, R., Zaragoza, J., & Agelidis, V. G. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2512842 · Cited by 75
“The benefits from controlling the circulating current have been identified from the very early stages of work in the topology [17], [21] and multiple controllers with different control objectives have been proposed in the existing literature [7]–[24].”
BackgroundMethodEfficient Grounding for Modular Multilevel HVDC Converters (MMC) on the AC Side
Wang, H., Tang, G., He, Z., & Yang, J. (2014) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2014.2311796 · Cited by 80
“Under ideal operating conditions, the controlled voltage of and is [2], [8], [9]”
BackgroundOliveira, R., & Yazdani, A. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2523338 · Cited by 80
Analysis of MMC Energy-Based Control Structures for VSC-HVDC Links
Sánchez‐Sánchez, E., Prieto‐Araujo, E., Junyent‐Ferré, A., & Gomis‐Bellmunt, O. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2803136 · Cited by 80
“However, they are typically eliminated including the so-called Circulating Current Suppressing Control (CCSC) [9].”
BackgroundInfluentialA Voltage Level Based Model Predictive Control of Modular Multilevel Converter
Zhang, F., Li, W., & Joós, G. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2572671 · Cited by 85
“The circulating current was decomposed and suppressed by a pair of proportional-integral (PI) controllers in [10].”
BackgroundJung, J.-J., Lee, J.-H., Sul, S., Son, G. T., & Chung, Y.-H. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2730244 · Cited by 78
Improved Accuracy Average Value Models of Modular Multilevel Converters
Beddard, A., Sheridan, C. E., Barnes, M., & Green, T. C. (2016) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2016.2535410 · Cited by 85
Konstantinou, G. S., Pou, J., Ceballos, S., Darus, R., & Agelidis, V. G. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2416759 · Cited by 79
“However, improper regulation of the transitions at every switching instant results in a significant increase in the average SM switching frequency [23], [25].”
BackgroundPredictive Harmonic Control and Its Optimal Digital Implementation for MMC-Based Active Power Filter
Shu, Z., Liu, M., Zhao, L., Song, S., Zhou, Q., & He, X. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2570202 · Cited by 78
“The control algorithm is composed of the active/reactive power control [27], [28] and the predictive harmonic control.”
MethodA Back-Stepping Control Method for Modular Multilevel Converters
Ahmadijokani, M., Mehrasa, M., Sleiman, M., Sharifzadeh, M., Sheikholeslami, A., & Al‐Haddad, K. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2962455 · Cited by 75
Modeling, Control Design, and Analysis of a Startup Scheme for Modular Multilevel Converters
Shi, X., Liu, B., Wang, Z., Li, Y., Tolbert, L. M., & Wang, F. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2436354 · Cited by 80
“modulation schemes [8], circulating current suppression strategies [9], capacitor voltage balancing schemes [10], [11], faulttolerant capability improvement [12], [13], etc.”
BackgroundBergna, G., Garces, A., Berne, E., Egrot, P., Arzande, A., Vannier, J.-C., & Molinas, M. (2014) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2013.2279300 · Cited by 73
Konstantinou, G. S., Ciobotaru, M., & Agelidis, V. G. (2011) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2011.6120031 · Cited by 82
Meng, Y., Yan, S., Wu, K., Ning, L., Li, X., Wang, X., & Wang, X. (2021) · Renewable Energy · doi:10.1016/j.renene.2021.07.137 · Cited by 76
DC–DC Autotransformer With Bidirectional DC Fault Isolating Capability
Lin, W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2491781 · Cited by 74
“The CCSC and CBA stands for circulating current suppressing control and capacitor voltage balancing algorithm that are commonly available lower level controls for an MMC [26].”
BackgroundSteady-State Modeling of Modular Multilevel Converter Under Unbalanced Grid Conditions
Shi, X., Wang, Z., Liu, B., Li, Y., Tolbert, L. M., & Wang, F. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2629472 · Cited by 73
“Moreover, the steady-state model can help the circulating current controller design and maximum modulation index calculation, using the same methodology discussed in [40] and [41] for balanced conditions.”
MethodZhang, Z., Xu, Z. G., Xue, Y., & Tang, G. (2014) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2013.2297442 · Cited by 76
“Due to the high flexibility in active and reactive power control [7]–[10], the MMC-based inverter can operate like a reactive power source and support the ac voltage of the inverter ac bus, which is a benefit to the security of the receiving ac grids.”
BackgroundSelf-citationDiab, M. S., Massoud, A. M., Ahmed, S., & Williams, B. W. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2735195 · Cited by 75
Hao, P., Xie, R. J., Wang, K., Deng, Y., He, X., & Zhao, R. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2514524 · Cited by 73
“Carrier phase-shifted pulse width modulation (CPS-PWM) is another important modulation scheme for MMCs due to the perfect harmonic performance [20], [21].”
BackgroundRobust Control Design of MMC-HVDC Systems Using Multivariable Optimal Guaranteed Cost Approach
Belhaouane, M. M., Ayari, M. I., Guillaud, X., & Braïek, N. B. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2900606 · Cited by 75
“the double line frequency, negative-sequence rotational frame [25], [26].”
BackgroundMethodCirculating Current Optimization Control of MMC
Reddy, G. A., & Shukla, A. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.2977565 · Cited by 73
Bergna‐Diaz, G., Suul, J. A., & D’Arco, S. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2727496 · Cited by 80
A Simplified Analytical Calculation Model of Average Power Loss for Modular Multilevel Converter
Yang, L., Li, Y., Li, Z., Wang, P., Xu, S., & Gou, R. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2779417 · Cited by 72
“Therefore, in order to calculate the loss of MMC by using the proposed simplified model, the value of Nban needs to be estimated for the methods in [23]–[25] according to the operation conditions.”
MethodWang, K., Deng, Y., Hao, P., Chen, G., Li, G., & He, X. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2813963 · Cited by 73
Wu, H., & Wang, X. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2951446 · Cited by 72
A Postfault Strategy to Control the Modular Multilevel Converter Under Submodule Failure
Yang, Q., Qin, J., & Saeedifard, M. (2016) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2449875 · Cited by 69
“Therefore, based on the CCS method in [25], the negative- and positive-sequence current controllers can be constructed based on the block diagram of Fig.”
MethodInfluentialThe Role of the Internal Energy in MMCs Operating in Grid-Forming Mode
Sánchez‐Sánchez, E., Prieto‐Araujo, E., & Gomis‐Bellmunt, O. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2961774 · Cited by 69
Decoupled Control of Modular Multilevel Converter Based on Intermediate Controllable Voltages
Yang, W., Song, Q., & Liu, W. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2549001 · Cited by 72
Zhou, J., Zhang, J., Wang, J., Zang, J., Shi, G., Feng, X., & Cai, X. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3006956 · Cited by 69
Cui, S., Lee, H.-J., Jung, J.-J., Lee, Y., & Sul, S. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2797934 · Cited by 69
Overvoltage Limitation Method of an Offshore Wind Farm With DC Series-Parallel Collection Grid
Zhang, H., Gruson, F., R., D. M. F., & Saudemont, C. (2018) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2018.2829929 · Cited by 68
“The balancing capacitor algorithm (BCA) is implemented, so that the SM capacitor voltages are regulated equally [18].”
MethodZhou, W., Sheng, J., Luo, H., Li, W., & He, X. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2849441 · Cited by 69
Sekiguchi, K., Khamphakdi, P., Hagiwara, M., & Akagi, H. (2014) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2290867 · Cited by 66
A Diagnosis Strategy for Multiple IGBT Open-Circuit Faults of Modular Multilevel Converters
Chen, X., Liu, J., Deng, Z., Song, S., Du, S., & Wang, D. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2997963 · Cited by 67
Cui, S., Kim, S., Jung, J.-J., & Sul, S. (2014) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2014.6803370 · Cited by 72
A Generalized Cross-Connected Submodule Structure for Hybrid Multilevel Converters
Mathew, E. C., Ghat, M. B., & Shukla, A. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2535117 · Cited by 63
Xu, Z. G., Wang, S., & Xiao, H. (2016) · IET Power Electronics · doi:10.1049/iet-pel.2015.0738 · Cited by 68
Self-citationA Novel Hybrid-Arm Bipolar MMC Topology With DC Fault Ride-Through Capability
Yu, X., Wei, Y., Jiang, Q., Xie, X., Liu, Y., & Wang, K. (2016) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2016.2593745 · Cited by 73
“Therefore, the inner current controller [2] and circulating current controller [19] implemented in d-q axis can be directly transplanted to the positive MMC to control the ac side currents and circulating currents.”
BackgroundMethodLiu, X., Lv, J., Gao, C., Chen, Z., Guo, Y. G., Gao, Z., & Tai, B. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2682013 · Cited by 64
“In addition, extra switching actions [29], [30] or high execution frequency of voltage sorting algorithms [31], [32] are usually involved, and the situation will deteriorate when the number of SMs is high [33].”
BackgroundGhat, M. B., & Shukla, A. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2751680 · Cited by 65
“A circulating current control is necessary to reduce such impacts [11]–[13].”
BackgroundSteady-State Loss Model of Half-Bridge Modular Multilevel Converters
Rodrigues, S., Papadopoulos, A., Kontos, E., Todorcevic, T., & Bauer, P. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2519510 · Cited by 61
Three-Phase Series-Connected Modular Multilevel Converter for HVDC Application
Hao, Q., Ooi, B., Gao, F., Wang, C., & Li, N. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2392389 · Cited by 66
An Adaptive Voltage-Balancing Method for High-Power Modular Multilevel Converters
Luo, Y., Li, Z., Xu, L., Xiong, X., Li, Y., & Zhao, C. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2703839 · Cited by 63
“The low switching frequency strategies, which determine the SMs’ operating states according to the arm current direction and the reference voltage change trend, is presented in [18] and [19].”
BackgroundMethodSelf-citationNew Measuring Technique for Reducing the Number of Voltage Sensors in Modular Multilevel Converters
Picas, R., Zaragoza, J., Pou, J., Ceballos, S., & Balcells, J. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2412658 · Cited by 62
“ever, if a voltage balancing algorithm with controlled switching frequency is used [25], [26], only one SM is activated or deactivated per switching transition, achieving a constant switching”
MethodShort‐circuit current calculation and performance requirement of HVDC breakers for MMC‐MTDC systems
Zhang, Z., & Xu, Z. G. (2015) · IEEJ Transactions on Electrical and Electronic Engineering · doi:10.1002/tee.22203 · Cited by 62
Self-citationAnalysis and Control of Modular Multilevel Converters under Asymmetric Arm Impedance Conditions
Zeng, R., Xu, L., Yao, L., & Finney, S. J. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2477057 · Cited by 61
“Many control strategies have been developed such as circulating current control [15-18] and energy-based modeling control [19-22].”
BackgroundMethodSelf-citationDual Harmonic Injection for Reducing the Submodule Capacitor Voltage Ripples of Hybrid MMC
Xu, J., Weicheng, D., Gao, C., Lu, F., Liang, J., Zhao, C., & Li, G. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.3027464 · Cited by 62
A New Parallel-Connected Diode-Clamped Modular Multilevel Converter With Voltage Self-Balancing
Gao, C., & Lv, J. (2017) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2017.2670662 · Cited by 60
Yang, W., Song, Q., Xu, S., Rao, H., & Liu, W. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2722011 · Cited by 62
“However, various methods can suppress the secondharmonic circulating currents [18]–[21].”
BackgroundKe, L., Zhang, Y., Yang, B., Luo, Z., & Liu, Z. (2020) · Neurocomputing · doi:10.1016/j.neucom.2020.11.037 · Cited by 60
Yu, F. Y., Lin, W., Wang, X., & Xie, D. G. (2014) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2014.2351397 · Cited by 62
“voltage-balancing control is only executed once the required number of on-state SMs of an arm changes [8], [11], [12].”
BackgroundMethodThe impact of voltage-balancing control on switching frequency of the modular multilevel converter
Li, Y., Jones, E. A., & Wang, F. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2448713 · Cited by 58
“Alternative methods achieving lower switching frequency are proposed in [11] and [12].”
BackgroundMethodSamajdar, D., Bhattacharya, T., & Dey, S. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2896932 · Cited by 62
Metadata
- Authors
- Tu, Q., Xu, Z., & Xu, L.
- Affiliations
- Zhejiang University (CN)
- Queen's University Belfast (GB)
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2011-07
- Volume
- 26
- Issue
- 3
- Pages
- 2009-2017
- ISSN
- 0885-8977 (ISSN-L)
- 1937-4208
- OpenAlex
- W2021871997
- Cited by
- 1,387
- References
- 22
- Citations by year
- 2026: 18 · 2025: 57 · 2024: 57 · 2023: 86 · 2022: 84 · 2021: 87 · 2020: 127 · 2019: 118 · 2018: 146 · 2017: 136 · 2016: 122 · 2015: 122 · 2014: 120 · 2013: 71 · 2012: 30
- FWCI
- 50.85
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Delivery (publishedVersion)
- Research Portal (Queen's University Belfast) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Keywords
- modular multilevel converter, switching frequency reduction, circulating current suppression, PI controller, converter losses
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.