Photovoltaic Generation Penetration Limits in Radial Distribution Systems
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Photovoltaic generating units connected to distribution systems represent a type of distributed generation (DG) that has been experiencing increased growth in recent years. Higher DG penetration levels may be interesting from many different points of view, but raise important issues about distribution system operation. Therefore, new techniques are needed to determine the maximum amount of DG that may be installed without requiring major changes in the existing electric power system. According to the literature, voltage rises at load bus bars are a serious limiting factor when installing DG. This paper presents and discusses studies proving that conductor ampacity and voltage rises are limiting factors that manifest themselves under different conditions. The present study highlights situations in which line overloads are more restrictive than voltage rises. Variation in substation voltage, load, and its power factor were simulated in a simplified radial distribution system model, and the amount of distributed generation that may be installed was obtained. Mathematic formulae were developed to determine the amount of distributed generation for existing utility systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jenkins, N. (2000) · Institution of Engineering and Technology eBooks · doi:10.1049/pbpo031e · Cited by 556
Distribution System Voltage Performance Analysis for High-Penetration Photovoltaics
Liu, E., & Bebic, J. (2008) · doi:10.2172/924648 · Cited by 159
Voltage Regulation in Radial Distribution Feeders with High Penetration of Photovoltaic
Tonkoski, R., & Lopes, L. A. C. (2008) · 2008 IEEE Energy 2030 Conference · doi:10.1109/energy.2008.4781021 · Cited by 115
Bebic, J. Z. (2008) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/924647 · Cited by 105
Cited by
State-of-the-art of hosting capacity in modern power systems with distributed generation
Ismael, S. M., Abdel Aleem, S. H. E., Abdelaziz, A. Y., & Zobaa, A. F. (2019) · Renewable Energy · doi:10.1016/j.renene.2018.07.008 · Cited by 599
Ehsan, A., & Yang, Q. (2018) · Applied Energy · doi:10.1016/j.apenergy.2017.10.106 · Cited by 524
Distributed Volt/VAr Control by PV Inverters
Jahangiri, P., & Aliprantis, D. C. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2256375 · Cited by 474
Zeraati, M., Hamedani Golshan, M. E., & Guerrero, J. M. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2636217 · Cited by 395
Haque, M. M., & Wolfs, P. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.04.025 · Cited by 331
On Distributed PV Hosting Capacity Estimation, Sensitivity Study, and Improvement
Ding, F., & Mather, B. (2017) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2016.2640239 · Cited by 291
Review of power system impacts at high PV penetration Part I: Factors limiting PV penetration
Gandhi, O., Kumar, D. S., Rodríguez-Gallegos, C. D., & Srinivasan, D. (2020) · Solar Energy · doi:10.1016/j.solener.2020.06.097 · Cited by 290
Mulenga, E., Bollen, M. H. J., & Etherden, N. (2020) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2019.105445 · Cited by 271
Pandi, V. R., Zeineldin, H. H., & Xiao, W. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2209687 · Cited by 244
“The penetration level of photovoltaic generation in radial distribution system considering the limits on voltage magnitudes and conductor current flow is investigated in [17].”
BackgroundMethods and strategies for overvoltage prevention in low voltage distribution systems with PV
Hashemi, S., & Østergaard, J. (2017) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2016.0277 · Cited by 212
Zeineldin, H. H., Mohamed, Y. A.-R. I., Khadkikar, V., & Pandi, V. R. (2013) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2263745 · Cited by 159
On Estimation and Sensitivity Analysis of Distribution Circuit’s Photovoltaic Hosting Capacity
Dubey, A., & Santoso, S. (2017) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2016.2622286 · Cited by 151
Review on the PV Hosting Capacity in Distribution Networks
Fatima, S., Püvi, V., & Lehtonen, M. (2020) · Energies · doi:10.3390/en13184756 · Cited by 137
“Finally, the idea of alteration of limiting factor has been established in [102] that investigated the manifestation of limiting factors under di ff erent network conditions and noticed that the voltage rise as the limiting factor is replaced by conductor ampacity by changing the substation voltage…”
BackgroundProbabilistic assessment of hosting capacity in radial distribution systems
Abad, M. S. S., Ma, J., Zhang, D., Ahmadyar, A. S., & Marzooghi, H. (2018) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2018.2819201 · Cited by 137
“The HC is estimated in [21], [22] based on the conductor capacity and voltage-rise issues.”
BackgroundProbabilistic hosting capacity for active distribution networks
Al-Saadi, H., Zivanovic, R., & Al-Sarawi, S. F. (2017) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2017.2698505 · Cited by 124
National Renewable Energy Lab. (NREL), G., Palmintier, B., USDOE Office of Energy Efficiency and Renewable Energy (EERE), S. E. T. O. (.-4., Broderick, R., Mather, B., Coddington, M., Baker, K., Ding, F., Reno, M., Lave, M., et al. (2016) · doi:10.2172/1253980 · Cited by 108
Maximum PV generation estimation method for residential low voltage feeders
Heslop, S., MacGill, I., & Fletcher, J. (2016) · Sustainable Energy, Grids and Networks · doi:10.1016/j.segan.2016.06.003 · Cited by 37
Lucas, A. (2018) · Applied Sciences · doi:10.3390/app8081333 · Cited by 35
“Voltage rise has been found to be one of the most important elements that limit the integration of high levels of solar generation in LV distribution systems [19].”
BackgroundYao, H., Qin, W., Jing, X., Zhu, Z., Wang, K., Han, X., & Wang, P. (2022) · Applied Energy · doi:10.1016/j.apenergy.2022.119681 · Cited by 33
An investigative study on penetration limits of distributed generation on distribution networks
Ampofo, D. O., Otchere, I. K., & Frimpong, E. A. (2017) · 2017 IEEE PES PowerAfrica · doi:10.1109/powerafrica.2017.7991289 · Cited by 19
“Consequently, researchers have investigated penetration limit factors [6-8].”
BackgroundKhan, H. A., & Rihan, M. (2023) · Computers and Electrical Engineering · doi:10.1016/j.compeleceng.2023.108872 · Cited by 14
Metadata
- Authors
- Shayani, R. A., & de Oliveira, M. A. G.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2011-08
- Volume
- 26
- Issue
- 3
- Pages
- 1625-1631
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W1624458896
- Cited by
- 299
- References
- 4
- FWCI
- 6.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.