The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Lower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art
Abstract
In the nearly six decades since researchers began to explore methods of creating them, exoskeletons have progressed from the stuff of science fiction to nearly commercialized products. While there are still many challenges associated with exoskeleton development that have yet to be perfected, the advances in the field have been enormous. In this paper, we review the history and discuss the state-of-the-art of lower limb exoskeletons and active orthoses. We provide a design overview of hardware, actuation, sensory, and control systems for most of the devices that have been described in the literature, and end with a discussion of the major advances that have been made and hurdles yet to be overcome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ZERO-MOMENT POINT — THIRTY FIVE YEARS OF ITS LIFE
VUKOBRATOVIĆ, M., & BOROVAC, B. (2004) · International Journal of Humanoid Robotics · doi:10.1142/s0219843604000083 · Cited by 2,038
Biomechanical design of the Berkeley lower extremity exoskeleton (BLEEX)
Zoss, A. B., Kazerooni, H., & Chu, A. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.871087 · Cited by 1,170
Adaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait
Blaya, J. A., & Herr, H. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.823266 · Cited by 741
Self-citationDonelan, J. M., Kram, R., & Kuo, A. D. (2002) · Journal of Experimental Biology · doi:10.1242/jeb.205.23.3717 · Cited by 670
Derivation of formulae used to calculate energy expenditure in man.
Brockway, J. M. (1987) · PubMed · Cited by 585
The RoboKnee: an exoskeleton for enhancing strength and endurance during walking
Pratt, J. E., Krupp, B. T., Morse, C. J., & Collins, S. H. (2004) · IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004 · doi:10.1109/robot.2004.1307425 · Cited by 567
A QUASI-PASSIVE LEG EXOSKELETON FOR LOAD-CARRYING AUGMENTATION
WALSH, C. J., ENDO, K., & HERR, H. (2007) · International Journal of Humanoid Robotics · doi:10.1142/s0219843607001126 · Cited by 427
Self-citationDesign and control of an exoskeleton for the elderly and patients
Kong, K., & Jeon, D. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.878550 · Cited by 403
Power assist method for HAL-3 using EMG-based feedback controller
Kawamoto, H., Lee, S., Kanbe, S., & Sankai, Y. (2004) · SMC'03 Conference Proceedings. 2003 IEEE International Conference on Systems, Man and Cybernetics. Conference Theme - System Security and Assurance (Cat. No.03CH37483) · doi:10.1109/icsmc.2003.1244649 · Cited by 392
An Ankle-Foot Orthosis Powered by Artificial Pneumatic Muscles
Ferris, D. P., Czerniecki, J. M., & Hannaford, B. (2005) · Journal of Applied Biomechanics · doi:10.1123/jab.21.2.189 · Cited by 376
Power Assist System HAL-3 for Gait Disorder Person
Kawamoto, H., & Sankai, Y. (2002) · Lecture Notes in Computer Science · doi:10.1007/3-540-45491-8_43 · Cited by 346
An improved powered ankle–foot orthosis using proportional myoelectric control
Ferris, D. P., Gordon, K. E., Sawicki, G. S., & Peethambaran, A. (2006) · Gait & Posture · doi:10.1016/j.gaitpost.2005.05.004 · Cited by 342
Popovic, M. B., Goswami, A., & Herr, H. (2005) · The International Journal of Robotics Research · doi:10.1177/0278364905058363 · Cited by 327
Self-citationThe Berkeley Lower Extremity Exoskeleton
Kazerooni, H., & Steger, R. (2006) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.2168164 · Cited by 293
Influence of carrying heavy loads on soldiers' posture, movements and gait
Attwells, R. L., Birrell, S. A., Hooper, R. H., & Mansfield, N. J. (2006) · Ergonomics · doi:10.1080/00140130600757237 · Cited by 291
On the Biomimetic Design of the Berkeley Lower Extremity Exoskeleton (BLEEX)
Chu, A., Kazerooni, H., & Zoss, A. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570789 · Cited by 258 · cited 2×
“The kinematics and actuation requirements of the exoskeleton were designed by assuming behavior similar to that of a 75 kg human and utilizing clinical gait analysis data for walking [24], [25].”
BackgroundMethodGriffin, T. M., Roberts, T. J., & Kram, R. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00944.2002 · Cited by 251
The rise of the body bots [robotic exoskeletons
Guizzo, E., & Goldstein, H. (2005) · IEEE Spectrum · doi:10.1109/mspec.2005.1515961 · Cited by 238
Development of a lightweight, underactuated exoskeleton for load-carrying augmentation
Walsh, C. J., Paluska, D., Pasch, K., Grand, W., Valiente, A., & Herr, H. (2006) · Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006. · doi:10.1109/robot.2006.1642234 · Cited by 220
Self-citationDevelopment of active anthropomorphic exoskeletons
Vukobratovic, M., Hristic, D., & Stojiljkovic, Z. (1974) · Medical & Biological Engineering · doi:10.1007/bf02629836 · Cited by 216
Gravity-Balancing Leg Orthosis and Its Performance Evaluation
Banala, S. K., Agrawal, S. K., Fattah, A., Krishnamoorthy, V., Hsu, W.-L., Scholz, J., & Rudolph, K. (2006) · IEEE Transactions on Robotics · doi:10.1109/tro.2006.882928 · Cited by 199
The Cosmed K4 Telemetry System as an Accurate Device for Oxygen Uptake Measurements during Exercise
Hausswirth, C., Bigard, A., & Le Chevalier, J. (1997) · International Journal of Sports Medicine · doi:10.1055/s-2007-972662 · Cited by 193
The Effects of backpack weight on the biomechanics of load carriage
Harman, E., Hoon, K., Frykman, P., & Pandorf, C. (2000) · doi:10.21236/ada377886 · Cited by 177
Development of power assisting suit for assisting nurse labor
YAMAMOTO, K., HYODO, K., ISHII, M., & MATSUO, T. (2002) · JSME International Journal Series C · doi:10.1299/jsmec.45.703 · Cited by 169 · cited 1×
“…the arms and increase the user's " leg press " capability from 100 to 180 kg. 2) Nurse-Assisting Exoskeleton: For more than a decade, researchers at Kanagawa Institute of Technology in Japan have been developing an exoskeleton for the purpose of assisting nurses during patient transfer [42], [43].”
BackgroundAn autonomous, underactuated exoskeleton for load-carrying augmentation
Walsh, C., Pasch, K., & Herr, H. (2006) · 2006 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2006.281932 · Cited by 162
Self-citationAn Efficient Robotic Tendon for Gait Assistance
Hollander, K. W., Ilg, R., Sugar, T. G., & Herring, D. E. (2006) · Journal of Biomechanical Engineering · doi:10.1115/1.2264391 · Cited by 161
Design of an electrically actuated lower extremity exoskeleton
Zoss, A., & Kazerooni, H. (2006) · Advanced Robotics · doi:10.1163/156855306778394030 · Cited by 160
Mosher, R. S. (1967) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/670088 · Cited by 142
Solomonow, M., Baratta, R. V., Hirokawa, S., Rightor, N., Walker, W., Beaudette, P., Shoji, H., & D'Ambrosia, R. D. (1989) · Orthopedics · doi:10.3928/0147-7447-19891001-06 · Cited by 141
Exotendons for assistance of human locomotion
van den Bogert, A. J. (2003) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-2-17 · Cited by 139
Predicting the intended motion with EMG signals for an exoskeleton orthosis controller
Fleischer, C., Reinicke, C., & Hommel, G. (2005) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2005.1545504 · Cited by 134
Solomonow, M., Aguilar, E., Reisin, E., Baratta, R. V., Best, R., Coetzee, T., & D'Ambrosia, R. D. (1997) · Orthopedics · doi:10.3928/0147-7447-19970401-08 · Cited by 118
Smart portable rehabilitation devices
Mavroidis, C., Nikitczuk, J., Weinberg, B., et al. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-18 · Cited by 111
Control of a Biomimetic "Soft-actuated" 10DoF Lower Body Exoskeleton
Costa, N. R. S., & Caldwell, D. G. (2006) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2006.1639137 · Cited by 87
Ruthenberg, B. J., Wasylewski, N. A., & Beard, J. E. (1997) · PubMed · Cited by 78
Kirtley, C. (2006) · Medical Entomology and Zoology · Cited by 73
Development of NTU wearable exoskeleton system for assistive technologies
Low, K. H., Liu, X., & Yu, H. (2006) · doi:10.1109/icma.2005.1626705 · Cited by 69
Development of Power Assisting Suit (Miniaturization of Supply System to Realize Wearable Suit)
YAMAMOTO, K., Ishii, M., HYODO, K., YOSHIMITSU, T., & Matsuo, T. (2003) · JSME International Journal Series C · doi:10.1299/jsmec.46.923 · Cited by 64
Exoskeletons for Human Performance Augmentation (EHPA): A Program Summary.
Garcia, E., Sater, J. M., & Main, J. A. (2002) · Journal of the Robotics Society of Japan · doi:10.7210/jrsj.20.822 · Cited by 64
Kawashima, N., Sone, Y., Nakazawa, K., et al. (2003) · Spinal Cord · doi:10.1038/sj.sc.3101494 · Cited by 59
Hybrid hydraulic-electric power unit for field and service robots
Amundson, K., Raade, J., Harding, N., & Kazerooni, H. (2005) · 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2005.1545452 · Cited by 55
Development of Externally Powered Lower Limb Orthosis with Bilateral-Servo Actuator
Saito, Y., Kikuchi, K., Negoto, H., et al. (2005) · doi:10.1109/icorr.2005.1501127 · Cited by 55
RehAbilitative Knee Orthosis Driven by Electro-Rheological Fluid Based Actuators
Nikitczuk, J., Weinberg, B., & Mavroidis, C. (2006) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2005.1570453 · Cited by 48
Biomechanics of Medical Devices
Ghista, D. N., & Fung, Y. C. (1982) · Journal of Biomechanical Engineering · doi:10.1115/1.3138317 · Cited by 40
Biomimetic Design of an Under-Actuated Leg Exoskeleton for Load-Carrying Augmentation
Walsh, C. J. (2006) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 31
The Analysis, Design and Implementation of a Model of an Exoskeleton to Support Mobility
Acosta-Marquez, C., & Bradley, D. A. (2005) · doi:10.1109/icorr.2005.1501061 · Cited by 30
Development of a mobility assist for the paralyzed, amputee, and spastic patient
Johnson, D., Repperger, D. W., & Thompson, G. H. (2002) · Southern Biomedical Engineering Conference (SBEC) · doi:10.1109/sbec.1996.493115 · Cited by 29
Phillips, C. A. (1989) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(89)90070-8 · Cited by 28
Exoskeleton Power and Torque Requirements Based on Human Biomechanics
Crowell, H. P., Boynton, A., & Mungiole, M. (2002) · Defense Technical Information Center (DTIC) · Cited by 27
Development of straight style transfer equipment for lower limbs disabled
Mori, Y., Takayama, K., & Nakamura, T. (2004) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2004.1307434 · Cited by 22
Gregorczyk, K. N., Obusek, J. P., Hasselquist, L., Bensel, J. M. S., Carolyn, K., Gutekunst, D. J., & Frykman, P. (2006) · Defense Technical Information Center (DTIC) · Cited by 20
Lower Limb Human Muscle Enhancer
Misuraca, J. J., & Mavroidis, C. (2001) · ASME International Mechanical Engineering Congress and Exposition (IMECE) · doi:10.1115/imece2001/dsc-24620 · Cited by 18
Cited by
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“Several related review papers have been published in recent years that comprehensively establish the state-ofthe-art in portable and active lower limb prosthetics, orthotics and exoskeletons, mostly in terms of the design and hardware realization [10-15].”
State of the Art and Future Directions for Lower Limb Robotic Exoskeletons
Young, A. J., & Ferris, D. P. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2521160 · Cited by 901
Review of assistive strategies in powered lower-limb orthoses and exoskeletons
Yan, T., Cempini, M., Oddo, C. M., & Vitiello, N. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.09.032 · Cited by 715
A soft robotic exosuit improves walking in patients after stroke
Awad, L. N., Bae, J., O’Donnell, K., De Rossi, S. M. M., Hendron, K., Sloot, L. H., Kudzia, P., Allen, S., Holt, K. G., Ellis, T. D., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aai9084 · Cited by 672
Biorobotics: Using robots to emulate and investigate agile locomotion
Ijspeert, A. J. (2014) · Science · doi:10.1126/science.1254486 · Cited by 491
Metadata
- Authors
- Dollar, A. M., & Herr, H.
- Venue
- IEEE Transactions on Robotics
- Published
- 2008-02
- Volume
- 24
- Issue
- 1
- Pages
- 144-158
- ISSN
- 1552-3098 (ISSN-L)
- OpenAlex
- W2144781570
- Cited by
- 1,327
- References
- 52
- FWCI
- 17.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.