Preventing unrecognised oesophageal intubation: a consensus guideline from the Project for Universal Management of Airways and international airway societies*
Open accessThe DOI matches its Crossref record; 81 of the 81 references it cites were found in a registry or an index.
Abstract
Summary: Across multiple disciplines undertaking airway management globally, preventable episodes of unrecognised oesophageal intubation result in profound hypoxaemia, brain injury and death. These events occur in the hands of both inexperienced and experienced practitioners. Current evidence shows that unrecognised oesophageal intubation occurs sufficiently frequently to be a major concern and to merit a co‐ordinated approach to address it. Harm from unrecognised oesophageal intubation is avoidable through reducing the rate of oesophageal intubation, combined with prompt detection and immediate action when it occurs. The detection of ‘sustained exhaled carbon dioxide’ using waveform capnography is the mainstay for excluding oesophageal placement of an intended tracheal tube. Tube removal should be the default response when sustained exhaled carbon dioxide cannot be detected. If default tube removal is considered dangerous, urgent exclusion of oesophageal intubation using valid alternative techniques is indicated, in parallel with evaluation of other causes of inability to detect carbon dioxide. The tube should be removed if timely restoration of sustained exhaled carbon dioxide cannot be achieved. In addition to technical interventions, strategies are required to address cognitive biases and the deterioration of individual and team performance in stressful situations, to which all practitioners are vulnerable. These guidelines provide recommendations for preventing unrecognised oesophageal intubation that are relevant to all airway practitioners independent of geography, clinical location, discipline or patient type.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cook, T. M., Woodall, N., & Frerk, C. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer058 · Cited by 2,415
Self-citationLeonard, M. (2004) · BMJ Quality & Safety · doi:10.1136/qhc.13.suppl_1.i85 · Cited by 2,322
Frerk, C., Mitchell, V. S., McNarry, A. F., Mendonca, C., Bhagrath, R., Patel, A., O’Sullivan, E. P., Woodall, N. M., & Ahmad, I. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aev371 · Cited by 2,214 · cited 1×
“This provides an opportunity to restore oxygen saturation if needed, re-oxygenate the functional residual capacity, evaluate the reasons sustained exhaled carbon dioxide was not previously detected and optimise intubating conditions (including sourcing a videolaryngoscope if not immediately available) before re-intuba…”
BackgroundSelf-citationApfelbaum, J. L., Hagberg, C. A., Connis, R. T., Abdelmalak, B. B., Agarkar, M., Dutton, R. P., Fiadjoe, J. E., Greif, R., Klock, P. A., Mercier, D., et al. (2022) · Anesthesiology · doi:10.1097/aln.0000000000004002 · Cited by 1,340
Self-citationCook, T. M., Woodall, N., Harper, J., & Benger, J. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer059 · Cited by 1,065
Self-citationEmergency Tracheal Intubation: Complications Associated with Repeated Laryngoscopic Attempts
Mort, T. C. (2004) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000122825.04923.15 · Cited by 995 · cited 1×
“While repeated attempts at laryngoscopy are associated with (though not necessarily causative of) increased airway complications [108, 109], when sustained exhaled carbon dioxide is not obtained, the risk–benefit ratio favours removal.”
BackgroundSafety at the Sharp End: A Guide to Non-Technical Skills
Flin, R. H., O'Connor, P. E., & Crichton, M. (2008) · Cited by 981
Guidelines for the management of tracheal intubation in critically ill adults
Higgs, A., McGrath, B. A., Goddard, C., Rangasami, J., Suntharalingam, G., Gale, R., & Cook, T. M. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2017.10.021 · Cited by 900 · cited 1×
“If lung ventilation via a facemask or supraglottic airway is not initially successful, airway rescue should be implemented using optimised attempts at one or more of facemask, supraglottic airway, tracheal tube or a front-ofneck approach as appropriate [1, 2, 6, 93].”
BackgroundSelf-citationThe Effects of Acute Stress on Performance: Implications for Health Professions Education
LeBlanc, V. R. (2009) · Academic Medicine · doi:10.1097/acm.0b013e3181b37b8f · Cited by 713 · cited 1×
“As an airway crisis evolves, the effects of stress on both individual and team function may lead to a significant deterioration in decision-making, compromised long-term memory, loss of situation awareness, impaired communication and decreased fine motor skills, in both inexperienced and experienced practitioners [50,…”
BackgroundIntubation Practices and Adverse Peri-intubation Events in Critically Ill Patients From 29 Countries
Russotto, V., Myatra, S. N., Laffey, J. G., Tassistro, E., Antolini, L., Bauer, P., Lascarrou, J. B., Szuldrzynski, K., Camporota, L., Pelosi, P., et al. (2021) · JAMA · doi:10.1001/jama.2021.1727 · Cited by 637 · cited 2×
“Equipment for monitoring exhaled carbon dioxide and pulse oximetry should be available in all locations where airway management is undertaken and should be used for all episodes of airway management [8, 30, 33, 67].”
BackgroundSelf-citationSakles, J. C., Chiu, S., Mosier, J., Walker, C., & Stolz, U. (2013) · Academic Emergency Medicine · doi:10.1111/acem.12055 · Cited by 565 · cited 1×
“While repeated attempts at laryngoscopy are associated with (though not necessarily causative of) increased airway complications [108, 109], when sustained exhaled carbon dioxide is not obtained, the risk–benefit ratio favours removal.”
BackgroundSelf-citationDifficult Airway Society guidelines for awake tracheal intubation (ATI) in adults
Ahmad, I., El‐Boghdadly, K., Bhagrath, R., Hodzovic, I., McNarry, A. F., Mir, F., O'Sullivan, E. P., Patel, A., Stacey, M., & Vaughan, D. (2020) · Anaesthesia · doi:10.1111/anae.14904 · Cited by 563
Self-citationApfelbaum, J. L., Hagberg, C. A., Connis, R. T., Abdelmalak, B., Agarkar, M., Dutton, R. P., Fiadjoe, J. E., Greif, R. T., Klock, P. A., Mercier, D. W., et al. (2022) · doi:10.48350/161339 · Cited by 526
Self-citationVideolaryngoscopy versus direct laryngoscopy for adults undergoing tracheal intubation
Hansel, J., Rogers, A. M., Lewis, S. R., Cook, T. M., & Smith, A. F. (2022) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011136.pub3 · Cited by 409 · cited 3×
“When undertaking repeat laryngoscopy to exclude oesophageal intubation, videolaryngoscopy is recommended whenever feasible [34, 53, 54].”
BackgroundSelf-citationPreoxygenation: physiologic basis, benefits, and potential risks
Nimmagadda, U., Salem, M. R., & Crystal, G. J. (2017) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001589 · Cited by 404
Videolaryngoscopy versus direct laryngoscopy for adult patients requiring tracheal intubation
Lewis, S. R., Butler, A. R., Parker, J., Cook, T. M., & Smith, A. F. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011136.pub2 · Cited by 374 · cited 3×
“When undertaking repeat laryngoscopy to exclude oesophageal intubation, videolaryngoscopy is recommended whenever feasible [34, 53, 54].”
BackgroundSelf-citationKlein, A. A., Meek, T., Allcock, E., Cook, T. M., Mincher, N., Morris, C., Nimmo, A. F., Pandit, J. J., Pawa, A., Rodney, G., et al. (2021) · Anaesthesia · doi:10.1111/anae.15501 · Cited by 340
Self-citationComparison of three different methods to confirm tracheal tube placement in emergency intubation
Grmec, Š. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1290-x · Cited by 332 · cited 4×
“5 mmHg) should be to check for the presence of spontaneous cardiac output and if this is absent, commence high-quality chest compressions [74].”
BackgroundInfluentialMyatra, S. N., Shah, A., Kundra, P., Patwa, A., Ramkumar, V., Divatia, J. V., Raveendra, U. S., Shetty, S. R., Ahmed, S. M., Doctor, J. R., et al. (2016) · Indian Journal of Anaesthesia · doi:10.4103/0019-5049.195481 · Cited by 294
Self-citationHalperin, J. L., Levine, G. N., Al-Khatib, S. M., Birtcher, K. K., Bozkurt, B., Brindis, R. G., Cigarroa, J. E., Curtis, L. H., Fleisher, L. A., Gentile, F., et al. (2016) · Circulation · doi:10.1161/cir.0000000000000312 · Cited by 291
The Use of Cognitive Aids During Emergencies in Anesthesia: A Review of the Literature
Marshall, S. (2013) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31829c397b · Cited by 279 · cited 1×
“Prior familiarity and training with the algorithm are essential to its effective use in clinical practice [147].”
Self-citationSilvestri, S., Ralls, G. A., Krauss, B., Thundiyil, J., Rothrock, S. G., Senn, A., Carter, E., & Falk, J. (2005) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2004.09.014 · Cited by 230
Alarm fatigue: impacts on patient safety
Ruskin, K. J., & Hueske-Kraus, D. (2015) · Current Opinion in Anaesthesiology · doi:10.1097/aco.0000000000000260 · Cited by 226
The Vortex: a universal ‘high-acuity implementation tool’ for emergency airway management
Chrimes, N. (2016) · British Journal of Anaesthesia · doi:10.1093/bja/aew175 · Cited by 226 · cited 7×
“This provides an opportunity to restore oxygen saturation if needed, re-oxygenate the functional residual capacity, evaluate the reasons sustained exhaled carbon dioxide was not previously detected and optimise intubating conditions (including sourcing a videolaryngoscope if not immediately available) before re-intuba…”
BackgroundMethodInfluentialSelf-citationPaolini, J.-B., Donati, F., & Drolet, P. A. (2012) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/s12630-012-9859-5 · Cited by 212 · cited 1×
“Strategies, that improve the ability of the videolaryngoscope screen to be easily viewed by the whole team, are likely to further augment teamwork and are encouraged [62].”
BackgroundArulkumaran, N., Lowe, J., Ions, R., Mendoza, M. L., Bennett, V., & Dünser, M. W. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2017.12.041 · Cited by 195
Further Evolution of the ACC/AHA Clinical Practice Guideline Recommendation Classification System
Halperin, J. L., Levine, G. N., Al-Khatib, S. M., Birtcher, K. K., Bozkurt, B., Brindis, R. G., Cigarroa, J. E., Curtis, L. H., Fleisher, L. A., Gentile, F., et al. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.09.001 · Cited by 191 · cited 1×
“The recommendations in this guideline are categorised according to the American Heart Association recommendation classification system in online Supporting Information (Appendix S1) [45].”
MethodDe Jong, A., Molinari, N., Conseil, M., Coisel, Y., Pouzeratte, Y., Belafia, F., Jung, B., Chanques, G., & Jaber, S. (2014) · Intensive Care Medicine · doi:10.1007/s00134-014-3236-5 · Cited by 190
Evaluation of An End-Tidal CO2 Detector During Pediatric Cardiopulmonary Resuscitation
Bhende, M. S., & Thompson, A. E. (1995) · Pediatrics · doi:10.1542/peds.95.3.395 · Cited by 190
The assessment of three methods to verify tracheal tube placement in the emergency setting
Takeda, T., Tanigawa, K., Tanaka, H., Hayashi, Y., Goto, E., & Tanaka, K. (2003) · Resuscitation · doi:10.1016/s0300-9572(02)00345-3 · Cited by 186
Law, J. A., Duggan, L. V., Asselin, M., Baker, P., Crosby, E., Downey, A., Hung, O. R., Jones, P. M., Lemay, F., Noppens, R., et al. (2021) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-021-02007-0 · Cited by 184 · cited 1×
“If lung ventilation via a facemask or supraglottic airway is not initially successful, airway rescue should be implemented using optimised attempts at one or more of facemask, supraglottic airway, tracheal tube or a front-ofneck approach as appropriate [1, 2, 6, 93].”
BackgroundSelf-citationMulticenter study of a portable, hand-size, colorimetric end-tidal carbon dioxide detection device
Ornato, J. P., Shipley, J. B., Racht, E. M., Slovis, C. M., Wrenn, K. D., Pepe, P. E., Almeida, S.-L., Ginger, V. F., & Fotre, T. V. (1992) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(05)82517-x · Cited by 183
Cognitive errors detected in anaesthesiology: a literature review and pilot study
Stiegler, M. P., Neelankavil, J. P., Canales, C., & Dhillon, A. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aer387 · Cited by 182 · cited 4×
“A variety of cognitive biases contribute to failure to recognise oesophageal intubation and may mislead even the most skilled clinician [30, 47].”
BackgroundMethodInfluentialCapnography during cardiac arrest
Sandroni, C., De Santis, P., & D’Arrigo, S. (2018) · Resuscitation · doi:10.1016/j.resuscitation.2018.08.018 · Cited by 171 · cited 1×
“5 mmHg) would generally reflect either an incorrectly placed tube or a very high likelihood of a poor outcome from resuscitation [74, 94, 98].”
BackgroundChou, E. H.-C., Dickman, E., Tsou, P., Tessaro, M. O., Tsai, Y.-M., Huei‐Ming, M., Lee, C., & Marshall, J. P. (2015) · Resuscitation · doi:10.1016/j.resuscitation.2015.02.013 · Cited by 162
Woodall, N. M., & Cook, T. M. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aeq339 · Cited by 161 · cited 2×
“Based on the denominator data in NAP4 [42, 44], unrecognised oesophageal intubation causing severe harm occurred in approximately 1 in 1,000,000 tracheal intubations for anaesthesia, 1 in 15,000 in ICU and 1 in 10,000 in the emergency department.”
BackgroundSelf-citationVerification of endotracheal tube placement with colorimetric end-tidal CO2 detection
MacLeod, B. A., Heller, M. B., Gerard, J., Yealy, D. M., & Menegazzi, J. J. (1991) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(05)80937-0 · Cited by 161
Knapp, S., Kofler, J., Stoiser, B., Thalhammer, F., Burgmann, H., Posch, M., Hofbauer, R., Stanzel, M., & Frass, M. (1999) · Anesthesia & Analgesia · doi:10.1213/00000539-199904000-00016 · Cited by 158
Das, S. K., Choupoo, N. S., Haldar, R., & Lahkar, A. (2014) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/s12630-014-0301-z · Cited by 157
JSA airway management guideline 2014: to improve the safety of induction of anesthesia
Japanese Society of Anesthesiologists (2014) · Journal of Anesthesia · doi:10.1007/s00540-014-1844-4 · Cited by 156
Bozeman, W. P., Hexter, D. A., Liang, H. K., & Kelen, G. D. (1996) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(96)70162-2 · Cited by 153
Gottlieb, M. A., Holladay, D., & Peksa, G. D. (2018) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2018.06.024 · Cited by 152
Mosier, J. M., Whitmore, S. P., Bloom, J. W., Snyder, L. S., Graham, L. A., Carr, G. E., & Sakles, J. C. (2013) · Critical Care · doi:10.1186/cc13061 · Cited by 135
Self-citationScandinavian SSAI clinical practice guideline on pre‐hospital airway management
Rehn, M., Hyldmo, P. K., Magnússon, V., Kurola, J. O., Kongstad, P., Rognås, L. K., Juvet, L. K., & Sandberg, M. (2016) · Acta Anaesthesiologica Scandinavica · doi:10.1111/aas.12746 · Cited by 123
Mort, T. C. (2005) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2005.02.004 · Cited by 95
Brown, C. A., Kaji, A. H., Fantegrossi, A., Carlson, J. N., April, M. D., Kilgo, R., Walls, R. M., & the National Emergency Airway Registry (NEAR) Investigators (2020) · Academic Emergency Medicine · doi:10.1111/acem.13851 · Cited by 92
A disposable end-tidal CO2 detector to verify endotracheal intubation
Anton, W. R., Gordon, R. W., Jordan, T. M., Posner, K. L., & Cheney, F. W. (1991) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(05)80938-2 · Cited by 89
Out‐of‐hospital Experience with the Syringe Esophageal Detector Device
Pelucio, M. T., Halligan, L., & Dhindsa, H. S. (1997) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.1997.tb03579.x · Cited by 86
Human factors enablers and barriers for successful airway management – an in‐depth interview study
Schnittker, R., Marshall, S. D., Horberry, T., & Young, K. L. (2018) · Anaesthesia · doi:10.1111/anae.14302 · Cited by 85
Self-citationHypes, C. D., Stolz, U., Sakles, J. C., Joshi, R., Natt, B., Malo, J., Bloom, J. W., & Mosier, J. M. (2015) · Annals of the American Thoracic Society · doi:10.1513/annalsats.201508-505oc · Cited by 79
Self-citationMortality associated with anaesthesia: A case review study
Gannon, K. (1991) · Anaesthesia · doi:10.1111/j.1365-2044.1991.tb09859.x · Cited by 73
Göksu, E., Kılıç, T., Yıldız, G., Ünal, A. Y., & Kartal, M. (2016) · Turkish Journal of Emergency Medicine · doi:10.1016/j.tjem.2016.02.001 · Cited by 58
Bhattacharjee, S., Maitra, S., & Baidya, D. K. (2018) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2018.03.006 · Cited by 58 · cited 3×
“When undertaking repeat laryngoscopy to exclude oesophageal intubation, videolaryngoscopy is recommended whenever feasible [34, 53, 54].”
BackgroundJooste, R., Roberts, F., Mndolo, S. K., Mabedi, D., Chikumbanje, S. S., Whitaker, D., & O’Sullivan, E. (2018) · Anaesthesia · doi:10.1111/anae.14426 · Cited by 55
Self-citationProject for Universal Management of Airways – part 1: concept and methods
Chrimes, N. C., Higgs, A., Law, J. A., Baker, P., Cooper, R. M., Greif, R., Kovacs, G. J., Myatra, S. N., O’Sullivan, E., Rosenblatt, W. H., et al. (2020) · Anaesthesia · doi:10.1111/anae.15269 · Cited by 52 · cited 2×
“The method for developing these recommendations was recently published [32].”
MethodSelf-citationThe Global Oximetry Initiative
Thoms, G., McHugh, G. A., & O’Sullivan, E. (2007) · Anaesthesia · doi:10.1111/j.1365-2044.2007.05305.x · Cited by 50
Self-citationRamkumar, V., Dinesh, E., Shetty, S. R., Shah, A. J., Kundra, P., Das, S., Myatra, S. N., Ahmed, S. M., Divatia, J. V., Patwa, A., et al. (2016) · Indian Journal of Anaesthesia · doi:10.4103/0019-5049.195482 · Cited by 49
Self-citationComparison of Static versus Dynamic Ultrasound for the Detection of Endotracheal Intubation
Gottlieb, M. A., Nakitende, D., Sundaram, T., Serici, A. J., Shah, S. C., & Bailitz, J. M. (2018) · Western Journal of Emergency Medicine · doi:10.5811/westjem.2017.12.36714 · Cited by 44 · cited 1×
“36714 [111] and licensed under aCreative CommonsAttribution 4.”
BackgroundIs it time for airway management education to be mandatory?
Baker, P., Feinleib, J. L., & O’Sullivan, E. (2016) · British Journal of Anaesthesia · doi:10.1093/bja/aew129 · Cited by 42 · cited 1×
“However, time-consuming or unfamiliar manoeuvres should be avoided [112].”
BackgroundSelf-citationChrimes, N. C., Higgs, A., & Rehak, A. (2020) · British Journal of Anaesthesia · doi:10.1016/j.bja.2020.04.052 · Cited by 42 · cited 1×
“The potential for enhanced displays or smart monitors [152], able to use information from gas measurements, pulse oximetry, volume and pressure readings to make a verbal declaration of the need to exclude oesophageal intubation or of the time elapsed since the oxygen saturation has dropped below a specified level shou…”
BackgroundSelf-citationImpact of capnography on patient safety in high- and low-income settings: a scoping review
Wollner, E., Nourian, M. M., Booth, W., Conover, S., Law, T. J., Lilaonitkul, M., Gelb, A. W., & Lipnick, M. S. (2020) · British Journal of Anaesthesia · doi:10.1016/j.bja.2020.04.057 · Cited by 41
Foy, K. E., Mew, E., Cook, T. M., Bower, J., Knight, P., Dean, S., Herneman, K., Marden, B., & Kelly, F. E. (2018) · Anaesthesia · doi:10.1111/anae.14359 · Cited by 40 · cited 1×
“Outside anaesthetic practice, the role of waveform capnography in neonates is debated and requires further research and consensus [87].”
BackgroundSelf-citationSharieff, G. Q., Rodarte, A., Wilton, N. C. T., & Bleyle, D. (2003) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2003.tb01340.x · Cited by 38
Honardar, M. R., Posner, K. L., & Domino, K. B. (2017) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001795 · Cited by 37
Efficacy of the FEF Colorimetric End-Tidal Carbon Dioxide Detector in Children
Kelly, J. S., Wilhoit, R. D., Re, B., & James, R. (1992) · Anesthesia & Analgesia · doi:10.1213/00000539-199207000-00009 · Cited by 36
Prehospital Cardiac Arrest Airway Management: An NAEMSP Position Statement and Resource Document
Carlson, J. N., Colella, M. R., Daya, M. R., Maio, V. J. D., Nawrocki, P., Nikolla, D. A., & Bosson, N. (2022) · Prehospital Emergency Care · doi:10.1080/10903127.2021.1971349 · Cited by 35 · cited 1×
“5 mmHg) would generally reflect either an incorrectly placed tube or a very high likelihood of a poor outcome from resuscitation [74, 94, 98].”
BackgroundSharieff, G. Q., Rodarte, A., Wilton, N. C. T., Silva, P. D., & Bleyle, D. (2003) · Annals of Emergency Medicine · doi:10.1067/mem.2003.185 · Cited by 33
The MacGyver bias and attraction of homemade devices in healthcare
Duggan, L. V., Marshall, S. D., Scott, J., Brindley, P. G., & Grocott, H. P. (2019) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/s12630-019-01361-4 · Cited by 32 · cited 1×
“While the oesophageal detector device can be assembled from commonly available equipment [118], this may inadvertently introduce hazards and commercially made devices are preferred [140].”
BackgroundSelf-citationRapid sequence induction of anaesthesia in UK emergency departments: a national census
Benger, J. R., & Hopkinson, S. (2010) · Emergency Medicine Journal · doi:10.1136/emj.2009.085423 · Cited by 28 · cited 2×
“Based on the denominator data in NAP4 [42, 44], unrecognised oesophageal intubation causing severe harm occurred in approximately 1 in 1,000,000 tracheal intubations for anaesthesia, 1 in 15,000 in ICU and 1 in 10,000 in the emergency department.”
BackgroundShinohara, K., Naito, H., Matsui, Y., & HIKONO, M. (2012) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2012.08.004 · Cited by 26
Pandit, J. J., Young, P., & Davies, M. T. (2021) · Anaesthesia · doi:10.1111/anae.15634 · Cited by 26 · cited 6×
“Interdisciplinary simulation training, including practice drills based on the accompanying algorithm could usefully form part of education programmes [8, 46, 148].”
BackgroundMethodInfluentialUse of capnography to confirm correct tracheal intubation during cardiac arrest
Cook, T. M., & Nolan, J. P. (2011) · Anaesthesia · doi:10.1111/j.1365-2044.2011.06964.x · Cited by 26 · cited 1×
“In the presence of high-quality chest compressions, cardiac arrest cannot be assumed to be the cause of inability to satisfy the criteria for sustained exhaled carbon dioxide [99], and certainly does not explain a `flat trace ́ (https://youtu.”
BackgroundSelf-citationCapnography prevents avoidable deaths
Cook, T. M., & Harrop‐Griffiths, W. (2019) · BMJ · doi:10.1136/bmj.l439 · Cited by 24
Self-citationExploring Decision Pathways in Challenging Airway Management Episodes
Schnittker, R., Marshall, S. D., Horberry, T., Young, K. L., & Lintern, G. (2017) · Journal of Cognitive Engineering and Decision Making · doi:10.1177/1555343417716843 · Cited by 22 · cited 1×
“Decisions during airway management are also strongly influenced by past experience which may lead practitioners to deprioritise infrequently encountered events as options when troubleshooting a problem [48].”
BackgroundSelf-citationRoche, T. R., Braun, J., Ganter, M. T., Meybohm, P., Herrmann, J., Zacharowski, K. D., Raimann, F. J., Piekarski, F., Spahn, D. R., Nöthiger, C. B., et al. (2021) · British Journal of Anaesthesia · doi:10.1016/j.bja.2021.07.015 · Cited by 21
Russotto, V., & Cook, T. M. (2021) · British Journal of Anaesthesia · doi:10.1016/j.bja.2021.08.010 · Cited by 16
Self-citationPreoxygenation and pulse oximetry may delay detection of esophageal intubation.
McShane, A. J., & Martin, J. L. (1987) · PubMed · Cited by 15
Kovacs, G. J., Duggan, L. V., & Brindley, P. G. (2016) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/s12630-016-0804-x · Cited by 13 · cited 2×
“Photo reproduced fromoriginal publication in Canadian Journal of Anesthesia [49] with permission.”
BackgroundSelf-citationReducing the risk of confirmation bias in unrecognised oesophageal intubation
Jafferji, D., Morris, R., & Levy, N. (2019) · British Journal of Anaesthesia · doi:10.1016/j.bja.2019.01.015 · Cited by 13
Evaluation of an enhanced pulse oximeter auditory display: a simulation study
Paterson, E., Sanderson, P. M., Salisbury, I. S., Burgmann, F., Mohamed, I., Loeb, R. G., & Paterson, N. A. B. (2020) · British Journal of Anaesthesia · doi:10.1016/j.bja.2020.05.038 · Cited by 9 · cited 1×
“The potential for enhanced displays or smart monitors [152], able to use information from gas measurements, pulse oximetry, volume and pressure readings to make a verbal declaration of the need to exclude oesophageal intubation or of the time elapsed since the oxygen saturation has dropped below a specified level shou…”
BackgroundThe PIC ‐ NIC survey: capnography and neonatal intensive care – a reply
Cook, T. M., Kelly, F. E., Foy, K. E., Mew, E., Bower, J., Marden, B., Dean, S., Knight, P., & Herneman, K. (2018) · Anaesthesia · doi:10.1111/anae.14529 · Cited by 4 · cited 1×
“While the concerns raised are acknowledged, they have limited applicability to the peri-intubation setting and supportive data are lacking [88, 89].”
BackgroundSelf-citation
Metadata
- Authors
- Chrimes, N., Higgs, A., Hagberg, C. A., Baker, P. A., Cooper, R. M., Greif, R., Kovacs, G., Law, J. A., Marshall, S. D., Myatra, S. N., O'Sullivan, E. P., Rosenblatt, W. H., Ross, C. H., Sakles, J. C., Sorbello, M., & Cook, T. M.
- Venue
- Anaesthesia
- Publisher
- Wiley
- Published
- 2022-08-17
- Volume
- 77
- Issue
- 12
- Pages
- 1395-1415
- ISSN
- 0003-2409 (ISSN-L)
- 1365-2044
- OpenAlex
- W4292340142
- Cited by
- 228
- References
- 81
- FWCI
- 46.06
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.