CoChat

Advances in implantable bionic devices for blindness: a review

Open access
Lewis, Philip M., Ayton, Lauren N., Guymer, Robyn H., Lowery, Arthur J., Blamey, Peter J., Allen, Penelope J., Luu, Chi D., Rosenfeld, Jeffrey V. · 2016 · ANZ Journal of Surgery
Cited by 87

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Abstract

Since the 1950s, vision researchers have been working towards the ambitious goal of restoring a functional level of vision to the blind via electrical stimulation of the visual pathways. Groups based in Australia, USA, Germany, France and Japan report progress in the translation of retinal visual prosthetics from the experimental to clinical domains, with two retinal visual prostheses having recently received regulatory approval for clinical use. Regulatory approval for cortical visual prostheses is yet to be obtained; however, several groups report plans to conduct clinical trials in the near future, building upon the seminal clinical studies of Brindley and Dobelle. In this review, we discuss the general principles of visual prostheses employing electrical stimulation of the visual pathways, focusing on the retina and visual cortex as the two most extensively studied stimulation sites. We also discuss the surgical and functional outcomes reported to date for retinal and cortical prostheses, concluding with a brief discussion of novel developments in this field and an outlook for the future.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/ans.13616

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Research works printed but not linked: 35

  1. 10.1016/j.tibtech.2013.07.001 · DOI · Paper page
  2. 10.3389/fneng.2014.00024 · DOI · Paper page
  3. 10.1016/S0042-6989(03)00013-0 · DOI
  4. 10.1016/j.brs.2015.03.001 · DOI
  5. 10.1038/nphoton.2012.104 · DOI · Paper page
  6. Tassicker GE, 1956, Preliminary report on a retinal stimulator, Br. J. Physiol. Opt., 13, 102
  7. 10.1016/j.visres.2014.10.002 · DOI
  8. Lowery AJ, 2015, Restoration of vision using wireless cortical implants: The Monash Vision Group project, Conf. Proc. IEEE Eng. Med. Biol. Soc., 2015, 1041
  9. 10.1088/1741-2560/10/1/011002 · DOI · Paper page
  10. 10.1167/iovs.10-6836 · DOI · Paper page
  11. 10.1159/000354424 · DOI · Paper page
  12. 10.1167/iovs.13-12835 · DOI · Paper page
  13. Brindley GS, 1982, Effects of electrical stimulation of the visual cortex, Hum. Neurobiol., 1, 281
  14. Naumann J, 2012, Search for Paradise: A Patient's Account of the Artificial Vision Experiment
  15. Lane F, 2013, Participants' experiences in a clinical trial for vision restoration: motivation to participate, visual perception and functional use, and experience of loss following termination, Invest. Ophthalmol. Vis. Sci., 54, 5317
  16. 10.1088/1741-2560/6/3/035009 · DOI
  17. 10.1088/1741-2560/11/2/020301 · DOI · Paper page
  18. SrivastavaNR TroykPR TowleVLet al.Estimating phosphene maps for psychophysical experiments used in testing a cortical visual prosthesis device. 2007 3rd International IEEE/EMBS Conference on Neural Engineering Kohala Coast HI USA 2-5 May 2007. · DOI · Paper page
  19. 10.1088/1741-2560/4/1/S14 · DOI
  20. 10.1088/1741-2560/4/2/R02 · DOI · Paper page
  21. 10.1038/ncomms3463 · DOI · Paper page
  22. 10.1038/nn.3620 · DOI · Paper page
  23. 10.1126/scitranslmed.3003100 · DOI · Paper page
  24. 10.3389/fneng.2014.00027 · DOI · Paper page
  25. Yagi T, 2009, Biohybrid visual prosthesis for restoring blindness, Int. J. Appl. Biomed. Eng., 2, 1
  26. 10.3171/foc.2006.20.5.5 · DOI · Paper page
  27. 10.1111/ceo.12287 · DOI · Paper page
  28. 10.1088/1741-2560/9/6/065003 · DOI · Paper page
  29. FengD McCarthyC. Enhancing scene structure in prosthetic vision using iso‐disparity contour perturbance maps. 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) Osaka Japan 3-7 Jul 2013. · DOI · Paper page
  30. 10.1016/j.conb.2015.01.018 · DOI
  31. 10.1016/j.pneurobio.2015.06.002 · DOI
  32. 10.1016/j.expneurol.2009.06.016 · DOI
  33. 10.1016/j.expneurol.2012.08.029 · DOI
  34. 10.1016/j.exer.2009.11.002 · DOI
  35. Chow AY, 2010, The artificial silicon retina in retinitis pigmentosa patients (an American Ophthalmological Association thesis), Trans. Am. Ophthalmol. Soc., 108, 120

Cited by

Metadata

Authors
Lewis, P. M., Ayton, L. N., Guymer, R. H., Lowery, A. J., Blamey, P. J., Allen, P. J., Luu, C. D., & Rosenfeld, J. V.
Venue
ANZ Journal of Surgery
Publisher
Wiley
Published
2016-06-14
Volume
86
Issue
9
Pages
654-659
ISSN
  • 1445-1433 (ISSN-L)
  • 1445-2197
OpenAlex
W2440167357
Cited by
87
References
24
FWCI
4.72
Type
journal article
Language
en
Open access
hybrid
Funders
  • Australian Research Council
  • Monash University

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.