CoChat

Acute microelectrode array implantation into human neocortex: preliminary technique and histological considerations

Open access
House, Paul A., MacDonald, Joel D., Tresco, Patrick A., Normann, Richard A. · 2006 · Neurosurgical Focus
Cited by 89

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Object: Researchers at The Center for Neural Interfaces at the University of Utah have designed and produced a silicon-based high-density microelectrode array that has been used successfully in mammalian models. The authors investigate the ability to transfer array insertion techniques to humans and examine the acute response of human cortical tissue to array implantation. Methods: Six patients who were scheduled to undergo temporal lobectomy surgery were enrolled in an Institutional Review Board–approved protocol. Before the patients underwent lateral temporal cortical resection, one or two high-density microelectrode arrays were implanted in each individual by using a pneumatic insertion device. Cortical tissue was then excised and preserved in formalin. The specimens were sectioned and stained for histological examination. Pneumatic insertion of a microelectrode array into human cortex in the operating room was feasible. There were no clinical complications associated with implantation and no evidence of significant insertion-related hemorrhage. Tissue responses ranged from mild cortical deformity to small focal hemorrhages several millimeters below the electrode tines. Based on initial results, the insertion device was modified. A footplate that mechanically isolates a small area of cortex and a calibrated micromanipulator were added to improve the reproducibility of insertion. Conclusions: A high-density microelectrode array designed to function as a direct cortical interface device can be implanted into human cortical tissue without acute clinical complications. Further modifications to the insertion device and array design are ongoing and future work will assess the functional significance of the tissue reactions observed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3171/foc.2006.20.5.5

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Research works printed but not linked: 6

  1. 10.1161/01.STR.0000143235.93497.03 · DOI · Paper page
  2. 10.1006/meth.2001.1231 · DOI · Paper page
  3. 10.1016/S0042-6989(99)00040-1 · DOI · Paper page
  4. 10.1088/1741-2560/2/2/005 · DOI · Paper page
  5. 10.1007/BF02368133 · DOI · Paper page
  6. 10.1038/416141a · DOI · Paper page

Cited by

See all 89

Metadata

Authors
House, P. A., MacDonald, J. D., Tresco, P. A., & Normann, R. A.
Venue
Neurosurgical Focus
Published
2006-05
Volume
20
Issue
5
Pages
1-4
ISSN
1092-0684 (ISSN-L)
OpenAlex
W2138980584
Cited by
89
References
5
FWCI
1.39
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Acute microelectrode array implantation into human neocortex: preliminary technique and histological considerations. https://app.cochat.ai/papers/10.3171/foc.2006.20.5.5
The paper
House, P. A., MacDonald, J. D., Tresco, P. A., & Normann, R. A. (2006). Acute microelectrode array implantation into human neocortex: preliminary technique and histological considerations. Neurosurgical Focus. https://doi.org/10.3171/foc.2006.20.5.5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.