The isector: a simple and direct method for generating isotropic, uniform random sections from small specimens
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
SUMMARY: The very simple and strong principle of vertical sections devised by Baddeley et al. has been a major advance in stereology when any kind of anisotropy is present in the specimen under study. On the other hand, some important stereological estimators still require isotropic, uniform random sections. This paper deals with a simple technique for embedding specimens in rubber moulds with spherical cavities. After the embedding, any handling of the resulting sphere independent of the specimen will induce isotropy of the final histological sections.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
GUNDERSEN, H. J. G., BENDTSEN, T. F., KORBO, L., MARCUSSEN, N., MØLLER, A., NIELSEN, K., NYENGAARD, J. R., PAKKENBERG, B., SØRENSEN, F. B., VESTERBY, A., et al. (1988) · APMIS · doi:10.1111/j.1699-0463.1988.tb05320.x · Cited by 2,929
Self-citationThe unbiased estimation of number and sizes of arbitrary particles using the disector
Sterio, D. C. (1984) · Journal of Microscopy · doi:10.1111/j.1365-2818.1984.tb02501.x · Cited by 2,519
Gundersen, H. J. G., Bagger, P., Bendtsen, T. F., Evans, S. M., Korbo, L., Marcussen, N., MØLler, A., Nielsen, K., Nyengaard, J. R., Pakkenberg, B., et al. (1988) · APMIS · doi:10.1111/j.1699-0463.1988.tb00954.x · Cited by 2,478
Self-citationEstimation of surface area from vertical sections
Baddeley, A. J., Gundersen, H. J. G., & Cruz‐Orive, L. M. (1986) · Journal of Microscopy · doi:10.1111/j.1365-2818.1986.tb04282.x · Cited by 1,058
Self-citationRecent stereological methods for cell biology: a brief survey
Cruz-Orive, L. M., & Weibel, E. R. (1990) · American Journal of Physiology-Lung Cellular and Molecular Physiology · doi:10.1152/ajplung.1990.258.4.l148 · Cited by 506
Gundersen, H. J. G., & Jensen, E. B. (1985) · Journal of Microscopy · doi:10.1111/j.1365-2818.1985.tb02607.x · Cited by 489
Self-citationGundersen, H. J. G. (1988) · Journal of Microscopy · doi:10.1111/j.1365-2818.1988.tb04609.x · Cited by 448
Self-citationEstimation of surface area and length with the orientator
Mattfeldt, T., Mall, G., Gharehbaghi, H., & Möller, P. (1990) · Journal of Microscopy · doi:10.1111/j.1365-2818.1990.tb03036.x · Cited by 376
Distribution of Membrane Thickness Determined By Lineal Analysis
Gundersen, H. J. G., Jensen, T. B., & Østerby, R. (1978) · Journal of Microscopy · doi:10.1111/j.1365-2818.1978.tb00091.x · Cited by 127
Self-citationUnbiased estimation of curve length in 3‐D using vertical slices
Gokhale, A. M. (1990) · Journal of Microscopy · doi:10.1111/j.1365-2818.1990.tb04771.x · Cited by 122
Cited by
Hsia, C. C. W., Hyde, D. M., Ochs, M., & Weibel, E. R. (2010) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200809-1522st · Cited by 902
Design-based stereology in neuroscience
Schmitz, C., & Hof, P. R. (2005) · Neuroscience · doi:10.1016/j.neuroscience.2004.08.050 · Cited by 681
Marked loss of myelinated nerve fibers in the human brain with age
Marner, L., Nyengaard, J. R., Tang, Y., & Pakkenberg, B. (2003) · Journal of Comparative Neurology · doi:10.1002/cne.10714 · Cited by 599
Self-citationTissue shrinkage and unbiased stereological estimation of particle number and size*
Dorph‐Petersen, K. ‐., Nyengaard, J. R., & Gundersen, H. J. G. (2001) · Journal of Microscopy · doi:10.1046/j.1365-2818.2001.00958.x · Cited by 539
Self-citationStereologic Methods and Their Application in Kidney Research
NYENGAARD, J. R. (1999) · Journal of the American Society of Nephrology · doi:10.1681/asn.v1051100 · Cited by 439
Self-citationA review of recent advances in stereology for quantifying neural structure
Mayhew, T. M. (1992) · Journal of Neurocytology · doi:10.1007/bf01191700 · Cited by 330
Age-Induced White Matter Changes in the Human Brain: A Stereological Investigation
Tang, Y., Nyengaard, J. R., Pakkenberg, B., & Gundersen, H. J. G. (1997) · Neurobiology of Aging · doi:10.1016/s0197-4580(97)00155-3 · Cited by 328
Self-citationKnudsen, L., Weibel, E. R., Gundersen, H. J. G., Weinstein, F. V., & Ochs, M. (2010) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01100.2009 · Cited by 281
Self-citationHow much is there really? Why stereology is essential in lung morphometry
Weibel, E. R., Hsia, C. C. W., & Ochs, M. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00808.2006 · Cited by 256
Roles for the pro-neurotrophin receptor sortilin in neuronal development, aging and brain injury
Jansen, P., Giehl, K., Nyengaard, J. R., Teng, K., Lioubinski, O., Sjoegaard, S. S., Breiderhoff, T., Gotthardt, M., Lin, F., Eilers, A., et al. (2007) · Nature Neuroscience · doi:10.1038/nn2000 · Cited by 248
Self-citationGundersen, H. J. G. (2002) · Journal of Microscopy · doi:10.1046/j.1365-2818.2002.01054.x · Cited by 207
“Before step 1, one may decide on rotating the specimen isotropically (using the Isector (Nyengaard & Gundersen, 1992) or the Orientator (Mattfeldt et al., 1990) or vertically (Baddeley et al., 1986)).”
MethodSelf-citationBoyce, R. W., Dorph-Petersen, K.-A., Lyck, L., & Gundersen, H. J. G. (2010) · Toxicologic Pathology · doi:10.1177/0192623310385140 · Cited by 197
“These randomly oriented sections used for length and surface area estimation are known as isotropic (IUR) sections (Mattfeldt et al. 1989; Nyengaard and Gundersen 1992) and vertical (VUR) uniform random sections (Baddeley et al.”
BackgroundSelf-citationWreford, N. G. (1995) · Microscopy Research and Technique · doi:10.1002/jemt.1070320505 · Cited by 182
Taking Tissue Samples from the Placenta: An Illustration of Principles and Strategies
Mayhew, T. M. (2008) · Placenta · doi:10.1016/j.placenta.2007.05.010 · Cited by 182
Ochs, M., & Mühlfeld, C. (2013) · American Journal of Physiology-Lung Cellular and Molecular Physiology · doi:10.1152/ajplung.00429.2012 · Cited by 171
Analyzing Renal Glomeruli with the New Stereology
Bertram, J. F. (1995) · International Review of Cytology · doi:10.1016/s0074-7696(08)62497-3 · Cited by 165
JENSEN, E. B. V., & GUNDERSEN, H. J. G. (1993) · Journal of Microscopy · doi:10.1111/j.1365-2818.1993.tb03321.x · Cited by 164
Self-citationA brief update on lung stereology
OCHS, M. (2006) · Journal of Microscopy · doi:10.1111/j.1365-2818.2006.01587.x · Cited by 164
A review of state-of-the-art stereology for better quantitative 3D morphology in cardiac research
Mühlfeld, C., Nyengaard, J. R., & Mayhew, T. M. (2010) · Cardiovascular Pathology · doi:10.1016/j.carpath.2008.10.015 · Cited by 161
“The orientator [22] is more suitable for larger samples while the isector [23] is more suitable for small samples.”
BackgroundSelf-citationBotting, K. J., McMillen, I. C., Forbes, H., Nyengaard, J. R., & Morrison, J. L. (2014) · Journal of the American Heart Association · doi:10.1161/jaha.113.000531 · Cited by 111
Self-citationEnriched environment increases the myelinated nerve fibers of aged rat corpus callosum
Zhao, Y., Shi, X., Qiu, X., Lu, W., Yang, S., Li, C., Chen, L., Zhang, L., Cheng, G., & Tang, Y. (2012) · The Anatomical Record · doi:10.1002/ar.22446 · Cited by 41
Metadata
- Authors
- Nyengaard, J. R., & Gundersen, H. J. G.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 1992-03
- Volume
- 165
- Issue
- 3
- Pages
- 427-431
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2159013151
- Cited by
- 294
- References
- 12
- FWCI
- 10.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.