An Implantable Neurocybernetic Prosthesis System
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Summary: The neurocybernetic prosthesis (Cyberonics, Inc.) is an implantable, multiprogrammable pulse generator that delivers constant current electrical signals to the vagus nerve for the purpose of reducing the frequency and/or severity of epileptic seizures. The device is implanted in a subcutaneous chest pocket just below the clavicle, similar to cardiac pacemaker placement. The stimulation signal is transmitted from the prosthesis to the vagus nerve through a stimulation lead. The prosthesis can be programmed using any IBM‐compatible personal computer with programming software and a programming wand. The electrodes used in the first group of patients were found to break at an unacceptable rate. Design modifications appear to have resolved this problem.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of Vagal Stimulation on Experimentally Induced Seizures in Rats
Woodbury, D. M., & Woodbury, J. W. (1990) · Epilepsia · doi:10.1111/j.1528-1157.1990.tb05852.x · Cited by 369
Considerations for Safety with Chronically Implanted Nerve Electrodes
Agnew, W. F., & McCreery, D. B. (1990) · Epilepsia · doi:10.1111/j.1528-1157.1990.tb05845.x · Cited by 184
Cited by
Ben‐Menachem, E., Mañon‐Espaillat, R., Ristanovic, R., Wilder, B. J., Stefan, H., Mirza, W., Tarver, W. B., Wernicke, J. F., & First International Vagus Nerve Stimulation Study Group (1994) · Epilepsia · doi:10.1111/j.1528-1157.1994.tb02482.x · Cited by 683
Self-citation(2020) · Operative Techniques in Epilepsy Surgery · doi:10.1055/b-0040-177306 · Cited by 397
Tissue damage thresholds during therapeutic electrical stimulation
Cogan, S. F., Ludwig, K. A., Welle, C. G., & Takmakov, P. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/021001 · Cited by 386
Schachter, S. C., & Saper, C. B. (1998) · Epilepsia · doi:10.1111/j.1528-1157.1998.tb01151.x · Cited by 348
Harshaw, C. (2015) · Psychological Bulletin · doi:10.1037/a0038101 · Cited by 302
The RNS System: responsive cortical stimulation for the treatment of refractory partial epilepsy
Sun, F. T., & Morrell, M. J. (2014) · Expert Review of Medical Devices · doi:10.1586/17434440.2014.947274 · Cited by 266
Vagus Nerve Stimulation for Treatment of Partial Seizures: 2. Safety, Side Effects, and Tolerability
Ramsay, R. E., Uthman, B. M., Augustinsson, L. E., Upton, A. R. M., Naritoku, D., Willis, J., Treig, T., Barolat, G., Wernicke, J. F., & First International Vagus Nerve Stimulation Study Group (1994) · Epilepsia · doi:10.1111/j.1528-1157.1994.tb02483.x · Cited by 260
The chemical neuroanatomy of vagus nerve stimulation
Ruffoli, R., Giorgi, F. S., Pizzanelli, C., Murri, L., Paparelli, A., & Fornai, F. (2011) · Journal of Chemical Neuroanatomy · doi:10.1016/j.jchemneu.2010.12.002 · Cited by 232
Fanselow, E. E., Reid, A. P., & Nicolelis, M. A. L. (2000) · The Journal of Neuroscience · doi:10.1523/jneurosci.20-21-08160.2000 · Cited by 201
History of implantable devices
Greatbatch, W., & Holmes, C. F. (1991) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.84185 · Cited by 191
Feasibility and Safety of Vagal Stimulation In Monkey Model
Lockard, J. S., Congdon, W. C., & DuCharme, L. L. (1990) · Epilepsia · doi:10.1111/j.1528-1157.1990.tb05844.x · Cited by 189
Suppression of Interictal Spikes and Seizures by Stimulation of the Vagus Nerve
McLachlan, R. S. (1993) · Epilepsia · doi:10.1111/j.1528-1157.1993.tb02112.x · Cited by 177
Salinsky, M. C. (1996) · Archives of Neurology · doi:10.1001/archneur.1996.00550110128021 · Cited by 166
Amar, A. P., Heck, C. N., Levy, M. L., Thomas, S., DeGiorgio, C. M., Oviedo, S., & Apuzzo, M. L. J. (1998) · Neurosurgery · doi:10.1097/00006123-199812000-00001 · Cited by 164
Jobe, P. C., & Browning, R. A. (2005) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2005.07.014 · Cited by 163
Ko, D., Heck, C., Grafton, S., Apuzzo, M. L. J., Couldwell, W. T., Chen, T., Day, J. D., Zelman, V., Smith, T., & DeGiorgio, C. M. (1996) · Neurosurgery · doi:10.1097/00006123-199608000-00061 · Cited by 158
Vagus Nerve Stimulation for Epilepsy and Depression
Milby, A. H., Halpern, C. H., & Baltuch, G. H. (2008) · Neurotherapeutics · doi:10.1016/j.nurt.2007.10.071 · Cited by 141
Vagus nerve stimulation for intractable epilepsy: a review
McLachlan, R. S. (1997) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199709000-00002 · Cited by 89
Clinical experience with a helical bipolar stimulating lead
TARVER, W. B., GEORGE, R. E., MASCHINO, S. E., HOLDER, L. K., & WERNICKE, J. F. (1992) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1992.tb02933.x · Cited by 46
Self-citationCharkhkar, H., Christie, B. P., Pinault, G. J., Tyler, D. J., & Triolo, R. J. (2019) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108414 · Cited by 19
Metadata
- Authors
- Terry, R., Tarver, W. B., & Zabara, J.
- Venue
- Epilepsia
- Publisher
- Wiley
- Published
- 1990-06
- Volume
- 31
- Issue
- s2
- Pages
- S33-7
- ISSN
- 0013-9580 (ISSN-L)
- 1528-1167
- OpenAlex
- W2056385557
- Cited by
- 96
- References
- 2
- FWCI
- 2.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.