Role of Cardiac Electrophysiologic Studies in Patients with Unexplained Recurrent Syncope
The DOI matches its Crossref record.
Abstract
Cardiac electrophysiologic studies (EPS) with programmed electrical stimulation (PES) were performed in 30 patients with recurrent syncope to uncover possible arrhythmic etiology. All patients had undergone thorough medical and neurologic evaluation prior to EPS without finding a definitive cause for syncope. In the majority of patients an arrhythmic etiology for syncope was suspected but could not be documented utilizing the 12‐lead surface ECG, extended in‐hospital and/or ambulatory monitoring (for ≥ 48 hours) and exercise testing prior to the EPS. The studies provided a clue to the possible underlying rhythm disturbance which could have caused syncope in 16/30 patients. Sustained or nonsustained ventricular tachycardia and/or ventricular fibrillation was induced in 11/30, sinus node dysfunction in 4/30 and intra‐His block in the remaining one. Fourteen of the 16 have remained free of symptoms following therapy based on results of EPS during a follow‐up period ranging from 6–30 months (mean 16.5 ± 7.8). In 2/16 syncope recurred (one arrhythmic and one non‐arrhythmic) despite pacemaker therapy for sinus node dysfunction detected during EPS. In the remaining 14/30 patients, EPS and PES did not induce arrhythmia which could account for patient symptomatology and therefore no specific therapy could be recommended. Eleven of these 14 patients experienced a recurrence of symptoms within a 6–25 month period (mean 16.2 ± 6.8). Of the 16 patients with inducible arrhythmias considered clinically significant, 15 had associated structural heart disease. On the other hand, of the 14 patients without clinically significant arrhythmias, structural heart disease could be detected in only three. It is concluded that cardiac arrhythmias constitute a common cause of unexplained syncope, particularly in patients with structural heart disease, and that EPS with PES can uncover the type of arrhythmic disturbance in a significant number of cases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Almquist, A., Goldenberg, I. F., Milstein, S., Chen, M.-Y., Chen, X., Hansen, R., Gornick, C. C., & Benditt, D. G. (1989) · New England Journal of Medicine · doi:10.1056/nejm198902093200603 · Cited by 651
Krahn, A. D., Klein, G. J., Yee, R., & Skanes, A. C. (2001) · Circulation · doi:10.1161/01.cir.104.1.46 · Cited by 405
CLINICAL GUIDELINE: Diagnosing Syncope: Part 2: Unexplained Syncope
Linzer, M., Yang, E. H., Estes, N. A. M., Wang, P., Vorperian, V. R., & Kapoor, W. N. (1997) · Annals of Internal Medicine · doi:10.7326/0003-4819-127-1-199707010-00014 · Cited by 313
ABI‐SAMRA, F., MALONEY, J. D., FOUAD‐TARAZI, F. M., & CASTLE, L. W. (1988) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1988.tb03973.x · Cited by 307
Sra, J. S., Jazayeri, M. R., Avitall, B., Dhala, A., Deshpande, S., Blanck, Z., & Akhtar, M. (1993) · New England Journal of Medicine · doi:10.1056/nejm199304153281504 · Cited by 284
Self-citationGuidelines for clinical intracardiac electrophysiological and catheter ablation procedures
Zipes, D. P., Dimarco, J. P., Gillette, P. C., Jackman, W. M., Myerburg, R. J., Rahimtoola, S. H., Ritchie, J. L., Cheitlin, M. D., Garson, A., Gibbons, R. J., et al. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)80037-h · Cited by 282
Incremental diagnostic yield of loop electrocardiographic recorders in unexplained syncope
Linzer, M., Pritchett, E. L. C., Pontinen, M., McCarthy, E., & Divine, G. W. (1990) · The American Journal of Cardiology · doi:10.1016/0002-9149(90)90591-n · Cited by 239
Utility of upright tilt-table testing in the evaluation and management of syncope of unknown origin
Grubb, B. P., Temesy-Armos, P., Hahn, H., & Elliott, L. (1991) · The American Journal of Medicine · doi:10.1016/0002-9343(91)90499-n · Cited by 231
Unexplained Syncope Evaluated by Electrophysiologic Studies and Head-up Tilt Testing
Sra, J. S., Anderson, A. J., Sheikh, S. H., Avitall, B., Tchou, P. J., Troup, P. J., Gilbert, C. J., Akhtar, M., & Jazayeri, M. R. (1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-12-1013 · Cited by 222
Self-citationThe etiology of syncope in patients with negative tilt table and electrophysiological testing
Krahn, A. D., Klein, G. J., Norris, C., & Yee, R. (1995) · Circulation · doi:10.1161/01.cir.92.7.1819 · Cited by 215
Is syncope a risk factor for poor outcomes? comparison of patients with and without syncope
Kapoor, W. N., & Hanusa, B. H. (1996) · The American Journal of Medicine · doi:10.1016/s0002-9343(95)00052-6 · Cited by 180
Use of ambulatory electrocardiographic (Holter) monitoring
DiMarco, J. P., & Philbrick, J. T. (1990) · Annals of Internal Medicine · doi:10.7326/0003-4819-113-1-53 · Cited by 177
Diagnostic evaluation of syncope
N. Kapoor, W. (1991) · The American Journal of Medicine · doi:10.1016/0002-9343(91)90511-u · Cited by 177
Shalev, Y., Gal, R., Tchou, P. J., Anderson, A. J., Avitall, B., Akhtar, M., & Jazayeri, M. R. (1991) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(91)90798-e · Cited by 167
Self-citationElectrophysiologic testing in bundle branch block and unexplained syncope
Morady, F., Higgins, J., Peters, R. W., Schwartz, A. B., Shen, E. N., Bhandari, A., Scheinman, M. M., & Sauvé, M. J. (1984) · The American Journal of Cardiology · doi:10.1016/0002-9149(84)90254-6 · Cited by 138
Diagnostic and prognostic implicatioins of recurrences in patients with syncope
Kapoor, W. N., Peterson, J., Wieand, H. S., & Karpf, M. (1987) · The American Journal of Medicine · doi:10.1016/0002-9343(87)90901-6 · Cited by 126
Olshansky, B., Mazuz, M., & Martins, J. B. (1985) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(85)80040-1 · Cited by 125
Long-term prognosis of patients undergoing electrophysiologic studies for syncope of unknown origin
Bass, E. B., Elson, J. J., Fogoros, R. N., Peterson, J., Arena, V. C., & Kapoor, W. N. (1988) · The American Journal of Cardiology · doi:10.1016/0002-9149(88)90257-3 · Cited by 103
Mittal, S., Hao, S. C., Iwai, S., Stein, K. M., Markowitz, S. M., Slotwiner, D. J., & Lerman, B. B. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01379-1 · Cited by 49
“This Kaplan-Meier curve compares the overall survival for patients with (dotted line 5 [VF(1)]) and without (solid line 5 [VF(2)]) inducible VF.”
Background
Metadata
- Authors
- AKHTAR, M., SHENASA, M., DENKER, S., GILBERT, C. J., & RIZWI, N.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 1983-03
- Volume
- 6
- Issue
- 2
- Pages
- 192-201
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2137339490
- Cited by
- 132
- References
- 0
- FWCI
- 14.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.