Applications of MALDI-TOF mass spectrometry in clinical diagnostic microbiology
Open accessThe DOI matches its Crossref record; 154 of the 154 references it cites were found in a registry or an index.
Abstract
Until recently, microbial identification in clinical diagnostic laboratories has mainly relied on conventional phenotypic and gene sequencing identification techniques. The development of matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) devices has revolutionized the routine identification of microorganisms in clinical microbiology laboratories by introducing an easy, rapid, high throughput, low-cost, and efficient identification technique. This technology has been adapted to the constraint of clinical diagnostic laboratories and has the potential to replace and/or complement conventional identification techniques for both bacterial and fungal strains. Using standardized procedures, the resolution of MALDI-TOF MS allows accurate identification at the species level of most Gram-positive and Gram-negative bacterial strains with the exception of a few difficult strains that require more attention and further development of the method. Similarly, the routine identification by MALDI-TOF MS of yeast isolates is reliable and much quicker than conventional techniques. Recent studies have shown that MALDI-TOF MS has also the potential to accurately identify filamentous fungi and dermatophytes, providing that specific standardized procedures are established for these microorganisms. Moreover, MALDI-TOF MS has been used successfully for microbial typing and identification at the subspecies level, demonstrating that this technology is a potential efficient tool for epidemiological studies and for taxonomical classification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surviving Sepsis Campaign: International Guidelines for Management of Severe Sepsis and Septic Shock
Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., Jaeschke, R., et al. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31827e83af · Cited by 9,694
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955 · cited 1×
“…various operative modes of the different mass analysers confer strengths and weaknesses in their performance characterized by mass accuracy, resolution, mass range, sensitivity, and scan speed and cost (Table S1) (Jonsson, 2001; Aebersold & Mann, 2003; Domon & Aebersold, 2006; Graham et al., 2007).”
BackgroundMass Spectrometry and Protein Analysis
Domon, B., & Aebersold, R. (2006) · Science · doi:10.1126/science.1124619 · Cited by 2,181
Seng, P., Drancourt, M., Gouriet, F., La Scola, B., Fournier, P., Rolain, J. M., & Raoult, D. (2009) · Clinical Infectious Diseases · doi:10.1086/600885 · Cited by 1,983 · cited 12×
“Seng et al. (2009) showed that an improved database is required as 50% of the total isolates (46) showing no identification by MALDI-TOF MS were anaerobic bacteria including Fusobacterium nucleatum and non-Clostridium anaerobes that had no reference in the Bruker database.”
BackgroundMethodResultInfluentialPathogenesis of infections due to coagulasenegative staphylococci
von Eiff, C., Peters, G., & Heilmann, C. (2002) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(02)00438-3 · Cited by 1,039
Clark, A. E., Kaleta, E. J., Arora, A., & Wolk, D. M. (2013) · Clinical Microbiology Reviews · doi:10.1128/cmr.00072-12 · Cited by 941
Characterization of intact microorganisms by MALDI mass spectrometry
Fenselau, C., & Demirev, P. A. (2001) · Mass Spectrometry Reviews · doi:10.1002/mas.10004 · Cited by 834
Ehrich, M., Nelson, M. R., Stanssens, P., Zabeau, M., Liloglou, T., Xinarianos, G., Cantor, C. R., Field, J. K., & van den Boom, D. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0507816102 · Cited by 812
The benefit of appropriate empirical antibiotic treatment in patients with bloodstream infection
Leibovici, Shraga, Drucker, Konigsberger, Samra, Pitlik, & Pitlik (1998) · Journal of Internal Medicine · doi:10.1046/j.1365-2796.1998.00379.x · Cited by 685
van Veen, S. Q., Claas, E. C. J., & Kuijper, E. J. (2010) · Journal of Clinical Microbiology · doi:10.1128/jcm.02071-09 · Cited by 667
Cited by
MALDI-TOF mass spectrometry: an emerging technology for microbial identification and diagnosis
Singhal, N., Kumar, M., Kanaujia, P. K., & Virdi, J. S. (2015) · Frontiers in Microbiology · doi:10.3389/fmicb.2015.00791 · Cited by 1,605
The global threat of antimicrobial resistance: science for intervention.
Roca, I., Akova, M., Baquero, F., Carlet, J., Cavaleri, M., Coenen, S., Cohen, J., Findlay, D., Gyssens, I., Heure, O. E., et al. (2015) · New Microbes and New Infections · doi:10.1016/j.nmni.2015.02.007 · Cited by 1,106
“and their use in the detection of resistance profiles to certain classes of antibiotics has provided excellent results [28].”
BackgroundLee, C.-R., Lee, J. H., Park, M., Park, K. S., Bae, I. K., Kim, Y. B., Cha, C.-J., Jeong, B. C., & Lee, S. H. (2017) · Frontiers in Cellular and Infection Microbiology · doi:10.3389/fcimb.2017.00055 · Cited by 1,016
How to manage Pseudomonas aeruginosa infections
Bassetti, M., Vena, A., Croxatto, A., Righi, E., & Guery, B. (2018) · Drugs in Context · doi:10.7573/dic.212527 · Cited by 746
Self-citationHasman, H., Saputra, D., Sicheritz-Ponten, T., Lund, O., Svendsen, C. A., Frimodt-Møller, N., & Aarestrup, F. M. (2014) · Journal of Clinical Microbiology · doi:10.1128/jcm.02452-13 · Cited by 542
Yarrowia lipolytica: Safety assessment of an oleaginous yeast with a great industrial potential
Groenewald, M., Boekhout, T., Neuvéglise, C., Gaillardin, C., van Dijck, P. W. M., & Wyss, M. (2014) · Critical Reviews in Microbiology · doi:10.3109/1040841x.2013.770386 · Cited by 498
Blood culture-based diagnosis of bacteraemia: state of the art
Opota, O., Croxatto, A., Prod'hom, G., & Greub, G. (2015) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2015.01.003 · Cited by 475
Self-citationModern clinical microbiology: new challenges and solutions
Fournier, P.-E., Drancourt, M., Colson, P., Rolain, J.-M., Scola, B. L., & Raoult, D. (2013) · Nature Reviews Microbiology · doi:10.1038/nrmicro3068 · Cited by 341
The Continuing Threat of Methicillin-Resistant Staphylococcus aureus
Gajdács, M. (2019) · Antibiotics · doi:10.3390/antibiotics8020052 · Cited by 318
Weis, C., Cuénod, A., Rieck, B., Dubuis, O., Graf, S., Lang, C., Oberle, M., Brackmann, M., Søgaard, K. K., Osthoff, M., et al. (2022) · Nature Medicine · doi:10.1038/s41591-021-01619-9 · Cited by 292
Current status of MALDI-TOF mass spectrometry in clinical microbiology
Hou, T.-Y., Chiang-Ni, C., & Teng, S.-H. (2019) · Journal of Food and Drug Analysis · doi:10.1016/j.jfda.2019.01.001 · Cited by 288
Meylan, P., Lang, C., Mermoud, S., Johannsen, A., Norrenberg, S., Hohl, D., Vial, Y., Prod’hom, G., Greub, G., Kypriotou, M., et al. (2017) · Journal of Investigative Dermatology · doi:10.1016/j.jid.2017.07.834 · Cited by 248
“Agar plates were read at 24 and 48 hours for the presence of bacterial colonies, and each colony presenting a specific morphotype (more likely to represent different bacterial species) was identified by matrix assisted laser desorption ionization-time of flight mass spectrometry (Croxatto et al., 2012).”
MethodSelf-citationAngeletti, S. (2017) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2016.09.003 · Cited by 247
“The instruments is equipped with laser emitting single pulses at frequencies of at least 50 Hz, allows a single sample analysis in less than 30 seconds and consequently the analysis of a batch of 100 samples in less than 1 h (Seng et al., 2009; Croxatto et al., 2012).”
BackgroundPhysiology of Acetic Acid Bacteria and Their Role in Vinegar and Fermented Beverages
Lynch, K. M., Zannini, E., Wilkinson, S., Daenen, L., & Arendt, E. K. (2019) · Comprehensive Reviews in Food Science and Food Safety · doi:10.1111/1541-4337.12440 · Cited by 245
MALDI-TOF Mass Spectrometry for Microorganism Identification
Dingle, T. C., & Butler-Wu, S. M. (2013) · Clinics in Laboratory Medicine · doi:10.1016/j.cll.2013.03.001 · Cited by 243
Tsuchida, S., Umemura, H., & Nakayama, T. (2020) · Molecules · doi:10.3390/molecules25204775 · Cited by 218
“The development of microbial ID using MS [16] began in the 1970s when gas chromatography–mass spectrometry (GC-MS) was used to identify microorganisms [17,18].”
MethodRapid bacterial genome sequencing: methods and applications in clinical microbiology
Bertelli, C., & Greub, G. (2013) · Clinical Microbiology and Infection · doi:10.1111/1469-0691.12217 · Cited by 218
“Although matrix-assisted laser desorption ionization time-offlight (MALDI-TOF) mass spectrometry (MS) has been a revolution in clinical microbiology, and may have significant applications in typing, identification, and even toxin detection [1], there is still no high-throughput approach with which to fully and rapidly…”
BackgroundSelf-citationCan MALDI-TOF Mass Spectrometry Reasonably Type Bacteria?
Sauget, M., Valot, B., Bertrand, X., & Hocquet, D. (2017) · Trends in Microbiology · doi:10.1016/j.tim.2016.12.006 · Cited by 214
Use of MALDI-TOF mass spectrometry for identification of bacteria that are difficult to culture
Biswas, S., & Rolain, J.-M. (2013) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2012.10.014 · Cited by 212
Clerc, O., Prod'hom, G., Vogne, C., Bizzini, A., Calandra, T., & Greub, G. (2013) · Clinical Infectious Diseases · doi:10.1093/cid/cis1204 · Cited by 212
“As already published, [4, 13] we documented a lower reliability of MALDI-TOF in cases of polymicrobial bacteremia, a situation where the Gram stain result is more informative.”
Self-citationEmerging Tools for Identification of Arthropod Vectors
Yssouf, A., Almeras, L., Raoult, D., & Parola, P. (2016) · Future Microbiology · doi:10.2217/fmb.16.5 · Cited by 195
Rahi, P., Prakash, O., & Shouche, Y. S. (2016) · Frontiers in Microbiology · doi:10.3389/fmicb.2016.01359 · Cited by 191
“Most of the biomarkers detected in MALDI-TOF spectra of intact bacterial cells have a molecular mass below 15 kDa (Ryzhov and Fenselau, 2001; Croxatto et al., 2012; Suarez et al., 2013).”
BackgroundGajdács, M., Spengler, G., & Urbán, E. (2017) · Antibiotics · doi:10.3390/antibiotics6040025 · Cited by 169
Benefits and Limitations of MALDI-TOF Mass Spectrometry for the Identification of Microorganisms
Rychert, J. (2019) · Journal of Infectiology · doi:10.29245/2689-9981/2019/4.1142 · Cited by 169
Methods for Rapid Diagnosis of Meningitis Etiology in Adults
Poplin, V., Boulware, D. R., & Bahr, N. C. (2020) · Biomarkers in Medicine · doi:10.2217/bmm-2019-0333 · Cited by 119
Electrochemical detection of single E. coli bacteria labeled with silver nanoparticles
Sepunaru, L., Tschulik, K., Batchelor-McAuley, C., Gavish, R., & Compton, R. G. (2015) · Biomaterials Science · doi:10.1039/c5bm00114e · Cited by 116
Biomedical Mass Spectrometry in Today's and Tomorrow's Clinical Microbiology Laboratories
van Belkum, A., Welker, M., Erhard, M., & Chatellier, S. (2012) · Journal of Clinical Microbiology · doi:10.1128/jcm.00420-12 · Cited by 100
Identification and differentiation of avian Mycoplasma species using MALDI-TOF MS
Baudler, L., Scheufen, S., Ziegler, L., Möller Palau-Ribes, F., Ewers, C., & Lierz, M. (2019) · Journal of Veterinary Diagnostic Investigation · doi:10.1177/1040638719856932 · Cited by 7
Metadata
- Authors
- Croxatto, A., Prod'hom, G., & Greub, G.
- Venue
- FEMS Microbiology Reviews
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-03
- Volume
- 36
- Issue
- 2
- Pages
- 380-407
- ISSN
- 0168-6445 (ISSN-L)
- 1574-6976
- OpenAlex
- W2115445096
- Cited by
- 997
- References
- 154
- FWCI
- 22.63
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.