The DOI matches its Crossref record; 63 of the 64 references it cites were found in a registry or an index.
Association of Ventilation Rates and CO2 Concentrations with Health andOther Responses in Commercial and Institutional Buildings
Open accessAbstract
This paper reviews current literature on the associations of ventilation rates and carbon dioxide concentrations in non-residential and non-industrial buildings (primarily offices) with health and other human outcomes. Twenty studies, with close to 30,000 subjects, investigated the association of ventilation rates with human responses, and 21 studies, with over 30,000 subjects, investigated the association of carbon dioxide concentration with these responses. Almost all studies found that ventilation rates below 10 Ls-1 per person in all building types were associated with statistically significant worsening in one or more health or perceived air quality outcomes. Some studies determined that increases in ventilation rates above 10 Ls-1 per person, up to approximately 20 Ls-1 per person, were associated with further significant decreases in the prevalence of sick building syndrome (SBS) symptoms or with further significant improvements in perceived air quality. The carbon dioxide studies support these findings. About half of the carbon dioxide studies suggest that the risk of sick building syndrome symptoms continued to decrease significantly with decreasing carbon dioxide concentrations below 800 ppm. The ventilation studies reported relative risks of 1.5-2 for respiratory illnesses and 1.1-6 for sick building syndrome symptoms for low compared to high low ventilation rates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Seppänen et al. [14] found that the risk of air-related health problems can be decreased when CO 2 concentrations fall below 800 ppm.”
From Investigation of Indoor Air Quality and the Identification of Influential Factors at Primary Schools in the North of China (2017) · cites this paper as [14]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1979) · Medical Entomology and Zoology · Cited by 11,252
Quasi-experimentation: Design and analysis issues for field settings
Shrout, P. E. (1980) · Evaluation and Program Planning · doi:10.1016/0149-7189(80)90063-4 · Cited by 6,091
Ventilation for Acceptable Indoor Air Quality
Falih, M. (2019) · Cited by 2,497
ASTM Special Technical Publication
Hannula, S., Wanagel, J., & Li, C. Y. (1986) · Cited by 1,225
Estimates of Improved Productivity and Health from Better Indoor Environments
Fisk, W. J., & Rosenfeld, A. H. (1997) · Indoor Air · doi:10.1111/j.1600-0668.1997.t01-1-00002.x · Cited by 551
Self-citationImpact of Temperature and Humidity on the Perception of Indoor Air Quality
Fang, L., Clausen, G., & Fanger, P. O. (1998) · Indoor Air · doi:10.1111/j.1600-0668.1998.t01-2-00003.x · Cited by 534
Risk of Sick Leave Associated with Outdoor Air Supply Rate, Humidification, and Occupant Complaints
Milton, D. K., Glencross, P. M., & WALTERS, M. D. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004212.x · Cited by 364
Apte, M. G., Fisk, W. J., & Daisey, J. M. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004246.x · Cited by 341
Self-citationHEALTH HAZARD EVALUATION REPORT
Reh, C. M., Fleeger, A., & Collins, J. W. (1989) · Cited by 316
Non-Specific Symptoms In Office Workers: A Review And Summary Of The Epidemiologic Literature
Mendell, M. J. (1993) · Indoor Air · doi:10.1111/j.1600-0668.1993.00003.x · Cited by 282
Self-citation
Research works printed but not linked: 37
- ACGIH, 1991, Documentation of the Threshold Limit Values and Biological Exposure Indices, Sixth Edition
- Aizlewood C., 1996, Proceedings of Indoor Air '96, 2, 895
- Apte M., 1999, Indoor CO2 concentrations and sick building syndrome: analysis of the 1994-1996 BASE study data
- Bluyssen P.M., 1995, Proceedings of Healthy Buildings '95, 1287
- Brightman H.S., 1999, Proceedings of Indoor Air '99, 1, 847
- Cochet C., 1995, Proceedings of Healthy Buildings '95, 3, 1359
- Emmerich S., 1999, Proceedings of IAQ '98, 191
- Fanger P.O., 1983, Proceedings of Management of Atmospheres in Tightly Enclosed Spaces, 45
- Fisk WJ., 1992, Proceedings of the 1992 International Symposium on Room Air Convection and Ventilation Effectiveness, 213
- Fisk W., 1998, Proceedings of the 1998 Summer School Study on Energy Efficiency in Buildings, 8.85
- Gamble J., 1986, Proceedings of IAQ 86, 16
- L. Groes (1995 ) "The European IAQ-audit project, Statistical analysis of indoor environmental factors ", Ph.D. thesis, Laboratory of Heating and Air Conditioning, Technical University of Denmark.
- Groes L., 1995, Proceedings of 4th International conference on Healthy Buildings, 1293
- Hall J., 1998, Proceedings of IAQ '98, 171
- Hodgson M.J., 1989, Proceedings of IAQ '89, 8
- Janssen J., 1986, Proceedings of IAQ '86, 161
- Mendell M.J., 1993, Proceedings of Indoor Air '93, 1, 713
- Menzies D., 1993, Proceedings of Indoor Air '93, 6, 551
- Milton D., 1998, American Journal of Respiratory Critical Care Medicine, 157, A647
- Mudarri D., 1997, ASHRAE Transactions, 103, 244
- Myhrvold A., 1996, Proceedings of Indoor Air '96, 4, 369
- Nagda N.L., 1991, Proceedings of IAQ '91, 101
- Nagda N., 1990, Proceedings of Indoor Air '90, 1, 281
- Nardell E.A., 1997, Proceedings of Healthy Buildings '97, 1, 301
- Nelson C.J., 1991, Proceedings of IAQ '91, 14
- Palonen J., 1990, Proceedings of Indoor Air '90, 1, 299
- Persily A., 1997, ASHRAE Transactions, 103, 1
- Persily A., 1987, ASHRAE Transactions, 93, 42
- Roulet C., 1995, Proceedings of 4th International conference on Healthy Buildings, 1299
- Seppanen O., 1999, Proceedings of IAQ '98, 257
- Sieber W., 1998, Proceedings of the Section of Statistics and the Environment, 115
- Smedje G., 1996, Proceedings of Indoor Air '96, 1, 413
- Sohn J-Y, 1994, Proceedings of Healthy Buildings '94, 397
- Sundell J., 1994, Indoor Air, 4, 10.1111/j.1600-0668.1994.tb00031.x · DOI
- Wu X., 1996, Proceedings of Indoor Air '96, 2, 919
- 10.1007/s004200050309 · DOI
- WaRlinder R., 1997, Acta Otolanryngol, 117, 724, 10.3109/00016489709113467 · DOI
Cited by
Sorted by citations
Items 301–400 of 875
Liu, X., Liu, X., Zhang, T., Ooka, R., & Kikumoto, H. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.107183 · Cited by 33
Tuomainen, M., Tuomainen, A., Liesivuori, J., & Pasanen, A. ‐. (2003) · Indoor Air · doi:10.1034/j.1600-0668.2003.00171.x · Cited by 33
What we Think we Know about Ventilation
Persily, A. K. (2006) · International Journal of Ventilation · doi:10.1080/14733315.2006.11683745 · Cited by 33
Accuracy of CO2 sensors in commercial buildings: a pilotstudy
Fisk, W. J., USDOE. Assistant Secretary for Energy Efficiency andRenewable Energy. Office of the Deputy Assistant Secretary for TechnologyDevelopment. Office of the Building Technologies, Faulkner, D., & Sullivan, D. P. (2006) · doi:10.2172/902450 · Cited by 33
Self-citationHuman-centred health-care environments: a new framework for biophilic design
Tekin, B. H., & Gutiérrez, R. U. (2023) · Frontiers in Medical Technology · doi:10.3389/fmedt.2023.1219897 · Cited by 32
Critical factors and thresholds for user satisfaction on air quality in office environments
Park, J., Loftness, V., Aziz, A., & Wang, T. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.106310 · Cited by 32
Yasin, A., Delaney, J., Cheng, C., & Pang, T. Y. (2022) · Applied Sciences · doi:10.3390/app12199450 · Cited by 32
Kaushik, A. K., Arif, M., Syal, M., Rana, M. Q., Oladinrin, O. T., Sharif, A. A., & Alshdiefat, A. S. (2022) · Sustainability · doi:10.3390/su142315719 · Cited by 31
Ma’bdeh, S. N., Al-Zghoul, A. A., Al-Radaideh, T., Bataineh, A., & Ahmad, S. (2020) · Heliyon · doi:10.1016/j.heliyon.2020.e05171 · Cited by 31
Prevalence and risk factors of sick building syndrome among office workers
Abdel-Hamid, M. A., Hakim, S. A., El-Okda, E.-S., & Mostafa, N. S. (2013) · Journal of the Egyptian Public Health Association · doi:10.1097/01.epx.0000431629.28378.c0 · Cited by 31
Serrano-Arellano, J., Gijón-Rivera, M., Riesco-Ávila, J. M., & Elizalde‐Blancas, F. (2014) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2013.12.078 · Cited by 31
Ongwandee, M., & Morrison, G. (2008) · Environmental Science & Technology · doi:10.1021/es071935j · Cited by 31
Experimental and numerical investigations of a new ventilation supply device based on confluent jets
Andersson, H., Cehlin, M., & Moshfegh, B. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.03.038 · Cited by 31
Human responses to high levels of carbon dioxide and air temperature
Tu, Z., Li, Y., Geng, S., Zhou, K., Wang, R., & Dong, X. M. (2020) · Indoor Air · doi:10.1111/ina.12769 · Cited by 30
Zhu, Y., Jin, X., Du, Z., & Fang, X. (2015) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2015.01.030 · Cited by 30
Rieser, A., Pfluger, R., Troi, A., Herrera-Avellanosa, D., Thomsen, K. E., Rose, J., Arsan, Z. D., Akkurt, G. G., Kopeinig, G., Guyot, G., et al. (2021) · Sustainability · doi:10.3390/su13042325 · Cited by 30
Ventilation in day care centers and sick leave among nursery children
Kolarik, B. D., Andersen, Z. J., Ibfelt, T., Engelund, E. H., Møller, E. B., & Bräuner, E. V. (2015) · Indoor Air · doi:10.1111/ina.12202 · Cited by 29
Subway simulation of CO 2 concentration during close mode operation
Wang, Y., Li, J., & Li, X. (2016) · Sustainable Cities and Society · doi:10.1016/j.scs.2016.09.007 · Cited by 29
Development of an indoor air purification system to improve ventilation and air quality
UNDI, G. S. N. V. K. S. N. S. (2021) · Heliyon · doi:10.1016/j.heliyon.2021.e08153 · Cited by 29
Demand controlled ventilation for multiple zone HVAC systems: CO 2 -based dynamic reset (RP 1547)
Lin, X., & Lau, J. (2014) · Science and Technology for the Built Environment · doi:10.1080/10789669.2014.945853 · Cited by 29
Joshi, S. S., Antolasic, F., Manorama, S. V., Bhargava, S. K., & Ippolito, S. J. (2018) · ACS Sustainable Chemistry & Engineering · doi:10.1021/acssuschemeng.7b04453 · Cited by 29
Enhancement of ventilation performance of a residential split-system air-conditioning unit
Sekhar, C. (2004) · Energy and Buildings · doi:10.1016/j.enbuild.2003.12.004 · Cited by 29
Natural Ventilation in Built Environment
Yang, T., & Clements-Croome, D. J. (2012) · Springer eBooks · doi:10.1007/978-1-4419-0851-3_488 · Cited by 29
Mydlarz, C., Conetta, R., Connolly, D., Cox, T. J., Dockrell, J. E., & Shield, B. M. (2012) · Building and Environment · doi:10.1016/j.buildenv.2012.10.020 · Cited by 28
Omri, A., Kahouli, B., Afi, H., & Kahia, M. (2022) · Journal of the Knowledge Economy · doi:10.1007/s13132-022-01024-8 · Cited by 32
Herbert, D., Sundaram, V., Lu, Y.-H., Bagchi, S., & Li, Z. (2007) · ACM Transactions on Autonomous and Adaptive Systems · doi:10.1145/1278460.1278462 · Cited by 28
Development of a framework for indoor air quality assessments in energy conservation districts
Rickenbacker, H. J., Collinge, W. O., Hasik, V., Ciranni, A., Smith, I., Colao, P., Sharrard, A. L., & Bilec, M. M. (2019) · Sustainable Cities and Society · doi:10.1016/j.scs.2019.101831 · Cited by 27
Assessment of peak power demand reduction available via modulation of building ventilation systems.
Young, M., Less, B. D., Dutton, S., Walker, I. S., Sherman, M. H., & Clark, J. D. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2020.109867 · Cited by 27
Can green schools influence academic performance?
Vakalis, D., Lepine, C., MacLean, H. L., & Siegel, J. A. (2020) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643389.2020.1753631 · Cited by 27
Investigation of indoor air quality in university residences using low-cost sensors
Afroz, R., Guo, X., Cheng, C.-W., Delorme, A., Duruisseau-Kuntz, R., & Zhao, R. (2023) · Environmental Science Atmospheres · doi:10.1039/d2ea00149g · Cited by 27
Gall, E. T., & Nazaroff, W. W. (2015) · Atmospheric Environment · doi:10.1016/j.atmosenv.2015.01.004 · Cited by 27
Litt, J., Goss, C. W., Diao, L., Allshouse, A. A., Diaz-Castillo, S., Bardwell, R. A., Hendrikson, E., Miller, S. L., & DiGuiseppi, C. G. (2009) · Journal of Immigrant and Minority Health · doi:10.1007/s10903-009-9261-8 · Cited by 26
Hänninen, O. (2012) · ACS Chemical Health & Safety · doi:10.1016/j.jchas.2012.12.001 · Cited by 27
An assessment of environmental conditions in bedrooms of contemporary low energy houses in Scotland
Sharpe, T., Porteous, C., Foster, J., & Shearer, D. (2014) · Indoor and Built Environment · doi:10.1177/1420326x14532389 · Cited by 27
Nagasawa, K., Rhodes, J. D., & Webber, M. E. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.07.057 · Cited by 27
Fisk, W. J., Seppänen, O., Faulkner, D. M., & Huang, J. (2003) · University of North Texas Digital Library (University of North Texas) · Cited by 27
Self-citationKim, M. K., & Leibundgut, H. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.02.012 · Cited by 26
Yüksel, A., Arıcı, M., Krajčík, M., & Karabay, H. (2019) · Sustainable Cities and Society · doi:10.1016/j.scs.2019.101809 · Cited by 26
Mikola, A., Hamburg, A., Kuusk, K., Kalamees, T., Voll, H., & Kurnitski, J. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.108698 · Cited by 26
An Investigation of Indoor Air Quality in a Recently Refurbished Educational Building
McLeod, R. S., Mathew, M., Salman, D., & Thomas, C. L. P. (2022) · Frontiers in Built Environment · doi:10.3389/fbuil.2021.769761 · Cited by 26
Barone, G. B., Buonomano, A., Forzano, C., Giuzio, G. F., & Palombo, A. (2022) · Energy · doi:10.1016/j.energy.2022.124466 · Cited by 27
CO2 Concentrations and Thermal Comfort Analysis at Onsite and Online Educational Environments
Alegría-Sala, A., Tardío, E. C., Casals, L. C., Macarulla, M., & Salom, J. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph192316039 · Cited by 26
WSN based indoor air quality monitoring in classrooms
Wang, S. K., Chew, S. P., Jusoh, M. T., Khairunissa, A., Leong, K. Y., & Azid, A. A. (2017) · AIP conference proceedings · doi:10.1063/1.4975296 · Cited by 26
A Natural Ventilation Alternative to the Passivhaus Standard for a Mild Maritime Climate
Sassi, P. (2013) · Buildings · doi:10.3390/buildings3010061 · Cited by 26
IAQ Evaluation Using an IoT CO2 Monitoring System for Enhanced Living Environments
Marques, G., & Pitarma, R. (2018) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-77712-2_112 · Cited by 25
Heat and mass transfer by natural convection in a square cavity filled with a mixture of Air–CO2
Serrano-Arellano, J., Xamán, J., Álvarez, G., & Gijón-Rivera, M. (2013) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2013.05.038 · Cited by 25
Ongwandee, M., Bettinger, S. S., & Morrison, G. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2005.00380.x · Cited by 25
Modelling Indoor Air Carbon Dioxide (Co2)Concentration Using Neural Network
Skön, J.-P., Johansson, M., Raatikainen, M., Leiviskä, K., & Kolehmainen, M. (2012) · doi:10.5281/zenodo.1077820 · Cited by 25
Monitoring and controlling buildings indoor air quality using WSN-based technologies
Lachhab, F., Bakhouya, M., Ouladsine, R., & Essaaidi, M. (2017) · International Conference on Control, Decision and Information Technologies (CoDIT) · doi:10.1109/codit.2017.8102676 · Cited by 25
Mustafa, M., Cook, M., & McLeod, R. S. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.112471 · Cited by 24
Dinh, T.-V., Lee, J., Ahn, J.-W., & Kim, J.-C. (2020) · Atmosphere · doi:10.3390/atmos11101024 · Cited by 24
Amine-Based Latex Coatings for Indoor Air CO2 Control in Commercial Buildings
Krishnamurthy, A., Salunkhe, B., Zore, A., Rownaghi, A. A., Schuman, T. P., & Rezaei, F. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b02934 · Cited by 24
Reda, I., AbdelMessih, R. N., Steit, M., & Mina, E. M. (2022) · International Journal of Thermal Sciences · doi:10.1016/j.ijthermalsci.2022.107686 · Cited by 24
Alaidroos, A., & Mosly, I. (2022) · Air Quality Atmosphere & Health · doi:10.1007/s11869-022-01277-x · Cited by 24
Grygierek, K., Nateghi, S., Ferdyn-Grygierek, J., & Kaczmarczyk, J. (2023) · Energies · doi:10.3390/en16020592 · Cited by 25
Karaiskos, P., Munian, Y., Martínez-Molina, A., & Alamaniotis, M. (2024) · Smart and Sustainable Built Environment · doi:10.1108/sasbe-10-2023-0308 · Cited by 24
Correlation amongst Indoor Air Quality, Ventilation and Carbon Dioxide
Sireesha, N. L. (2017) · Journal of Scientific Research · doi:10.3329/jsr.v9i2.31107 · Cited by 24
Predictive analytics in facilities management
Roskams, M., & Haynes, B. (2019) · Journal of Facilities Management · doi:10.1108/jfm-03-2019-0008 · Cited by 24
Hou, J., Sun, Y., Wang, P., Zhang, Q., Kong, X., & Sundell, J. (2020) · Indoor Air · doi:10.1111/ina.12742 · Cited by 23
Smart Classroom: A Review and Research Agenda
Kaur, A., & Bhatia, M. (2022) · IEEE Transactions on Engineering Management · doi:10.1109/tem.2022.3176477 · Cited by 23
Pati, S., Mohamad, Z., Cnaan, A., Kavanagh, J. E., & Shea, J. A. (2010) · American Journal of Public Health · doi:10.2105/ajph.2009.172742 · Cited by 23
Optimization of design flow rates and component sizing for residential ventilation
Laverge, J., & Janssens, A. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.03.019 · Cited by 23
Energy-Efficient Buildings as Complex Socio-technical Systems: Approaches and Challenges
Lachhab, F., Bakhouya, M., Ouladsine, R., & Essaaidi, M. (2016) · Nonlinear systems and complexity · doi:10.1007/978-3-319-46164-9_12 · Cited by 23
Biodeterioration of buildings and public health implications caused by indoor air pollution
Ahmed, T., Usman, M., & Scholz, M. (2017) · Indoor and Built Environment · doi:10.1177/1420326x17690912 · Cited by 23
Hussin, M., Ismail, M. R., & Ahmad, M. S. (2014) · Journal of King Saud University - Engineering Sciences · doi:10.1016/j.jksues.2014.08.005 · Cited by 23
WORKER PERFORMANCE AND VENTILATION: ANALYSES OF TIME-SERIES DATA FOR A GROUP OF CALL-CENTER WORKERS
Fisk, W. J., Faulkner, D. M., Sullivan, D., Dibartolomeo, D., Federspiel, C. C., Liu, G., & Lahiff, M. (2002) · eScholarship (California Digital Library) · Cited by 23
Self-citationHilo-wear: Exploring Wearable Interaction with Indoor Air Quality Forecast
Zhong, S., Alavi, H. S., & Lalanne, D. (2020) · CHI Conference Extended Abstracts on Human Factors in Computing Systems (CHI EA) · doi:10.1145/3334480.3382813 · Cited by 22
Ghoroghi, A., Rezgui, Y., & Wallace, R. (2022) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2022.156518 · Cited by 22
Seseña, S., Rodrı́guez, A., & Palop, M. L. (2022) · Air Quality Atmosphere & Health · doi:10.1007/s11869-022-01220-0 · Cited by 22
Analyzing indoor air pollutants in naturally ventilated athletic facilities. A case of study
Karaiskos, P., Martínez-Molina, A., & Alamaniotis, M. (2023) · Journal of Building Engineering · doi:10.1016/j.jobe.2023.107457 · Cited by 21
A Field Investigation of the Thermal Comfort of Older Adults in Cold Winter Climates
Larriva, M. T. B., Vergés, R., Gaspar, K., & Forcada, N. (2023) · Indoor Air · doi:10.1155/2023/9185216 · Cited by 22
Jeong, J., Choi, A., & No, S.-T. (2009) · Simulation Modelling Practice and Theory · doi:10.1016/j.simpat.2009.09.009 · Cited by 22
Elharidi, A. M., Tuohy, P. G., & Teamah, M. A. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.10.035 · Cited by 22
Persson, J., Wang, T., & Hagberg, J. (2018) · Indoor and Built Environment · doi:10.1177/1420326x18792600 · Cited by 22
Roskams, M., McNeely, E., Węziak‐Białowolska, D., & Białowolski, P. (2021) · Routledge eBooks · doi:10.1201/9781003128830-3 · Cited by 28
Subjective and objective sensory assessments of indoor air quality in college dormitories in Nanjing
Xu, L., Hu, Y., & Liang, W. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.108802 · Cited by 21
Choi, H., Kim, H., Hong, T., & An, J. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110278 · Cited by 21
Consequences of energy renovation on indoor air quality in kindergartens
Dovjak, M., Slobodnik, J., & Krainer, A. (2020) · Building Simulation · doi:10.1007/s12273-020-0613-6 · Cited by 21
Implementation and evaluation of air flow and heat transfer routines for building simulation tools
Tuomaala, P. (2002) · Aaltodoc (Aalto University) · Cited by 21
Ali, S. A., Shah, S. N., Karim, M. A., Hashmi, S. A. M., Ahmad, F., Habib, K., Sami, A., & Abdullah, M. (2025) · Energy & Fuels · doi:10.1021/acs.energyfuels.5c00793 · Cited by 21
Sanjuan-Delmás, D., Llorach-Massana, P., Nadal, A., Sanyé‐Mengual, E., Petit‐Boix, A., Ercilla‐Montserrat, M., Cuerva, E., Rovira, M. R., Josa, A., Muñoz, P., et al. (2018) · Sustainable development and biodiversity · doi:10.1007/978-3-319-67017-1_3 · Cited by 20
Newsham, G. R., Veitch, J. A., Zhang, M. Q., & Galasiu, A. D. (2019) · Intelligent Buildings International · doi:10.1080/17508975.2019.1588700 · Cited by 20
Zender-Świercz, E. J. (2021) · Energies · doi:10.3390/en14041176 · Cited by 19
Improving Environmental Health in Schools
Gouge, D. H., Lame, M. L., Stock, T. W., Rose, L. F., Hurley, J. A., Lerman, D. L., Nair, S., Nelson, M. A., Gangloff‐Kaufmann, J., McSherry, L., et al. (2023) · Current problems in pediatric and adolescent health care · doi:10.1016/j.cppeds.2023.101407 · Cited by 19
Nanomaterials in the field of design ergonomics: present status
Chowdhury, A., Sanjog, J., Reddy, S. M., & Karmakar, S. (2012) · Ergonomics · doi:10.1080/00140139.2012.720287 · Cited by 19
Weisel, C. P., Fiedler, N. L., Weschler, C. J., Ohman‐Strickland, P., Mohan, K. R., McNeil, K., & Space, D. R. (2017) · Indoor Air · doi:10.1111/ina.12392 · Cited by 19
Lachhab, F., Bakhouya, M., Ouladsine, R., & Essaaidi, M. (2018) · Proceedings of the Institution of Mechanical Engineers Part I Journal of Systems and Control Engineering · doi:10.1177/0959651818791406 · Cited by 19
McGill, G., Oyedele, L. O., & McAllister, K. (2015) · Smart and Sustainable Built Environment · doi:10.1108/sasbe-10-2014-0054 · Cited by 19
Zhang, X., Li, D., Xie, J., & Liu, J. (2021) · Indoor Air · doi:10.1111/ina.12793 · Cited by 18
Rizzo, K., Camilleri, M. A., Gatt, D., & Yousif, C. (2024) · Sustainability · doi:10.3390/su16020766 · Cited by 25
Balvís, E., Sampedro, Ó., Zaragoza, S., Paredes, Á., & Michinel, H. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.04.117 · Cited by 17
CuO Thin Films Functionalized with Gold Nanoparticles for Conductometric Carbon Dioxide Gas Sensing
Wimmer-Teubenbacher, R., Sosada-Ludwikowska, F., Travieso, B. Z., Defregger, S., Tokmak, O., Niehaus, J., Deluca, M., & Köck, A. (2018) · Chemosensors · doi:10.3390/chemosensors6040056 · Cited by 18
The physical work environment and its relationship to stress
Sander, L., Caza, A., & Jordan, P. J. (2019) · Routledge eBooks · doi:10.4324/9781315167237-15 · Cited by 21
Interaction between plant species and substrate type in the removal of CO2 indoors
Gubb, C., Blanuša, T., Griffiths, A., & Pfrang, C. (2019) · Air Quality Atmosphere & Health · doi:10.1007/s11869-019-00736-2 · Cited by 18
Berouine, A., Ouladsine, R., Bakhouya, M., & Essaaidi, M. (2020) · Energies · doi:10.3390/en13123246 · Cited by 18
Laquatra, J., Pillai, G. G., Singh, A., & Syal, M. (2008) · Journal of Architectural Engineering · doi:10.1061/(asce)1076-0431(2008)14:4(94 · Cited by 18
Airborne environmental injuries and human health
Borchers, A. T., Chang, C., Keen, C. L., & Gershwin, M. E. (2006) · Clinical Reviews in Allergy & Immunology · doi:10.1385/criai:31:1:1 · Cited by 17
An assessment of indoor air quality in recent Mexican immigrant housing in Commerce City, Colorado
Miller, S. L., Scaramella, P., Campe, J., Goss, C. W., Diaz-Castillo, S., Hendrikson, E., DiGuiseppi, C. G., & Litt, J. (2009) · Atmospheric Environment · doi:10.1016/j.atmosenv.2009.07.037 · Cited by 18
Perspective on distributed direct air capture: what, why, and how?
Chen, Y., Wu, R., & Hsu, P. (2025) · npj Materials Sustainability · doi:10.1038/s44296-025-00056-w · Cited by 17
Crosscutting of the pollutants and building ventilation systems: a literature review
Zuazua-Ros, A., Andrade, L. D. B., Dorregaray-Oyaregui, S., Martín-Gómez, C., Ramos, J. C., Manzueta, R., Sáiz-Esquerra, B. S., & Ariño, A. H. (2023) · Environmental Science and Pollution Research · doi:10.1007/s11356-023-27148-1 · Cited by 17
Metadata
- Authors
- Seppanen, O. A., Fisk, W. J., & Mendell, M. J.
- Affiliations
- Lawrence Berkeley National Laboratory (US)
- National Institute for Occupational Safety and Health (US)
- Corresponding author
- Fisk, W. J.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 1999-12
- Volume
- 9
- Issue
- 4
- Pages
- 226-252
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W2161463298
- Cited by
- 876
- References
- 64
- Citations by year
- 2026: 41 · 2025: 45 · 2024: 36 · 2023: 46 · 2022: 48 · 2021: 53 · 2020: 74 · 2019: 56 · 2018: 45 · 2017: 32 · 2016: 31 · 2015: 52 · 2014: 51 · 2013: 29 · 2012: 38
- FWCI
- 2.63
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Indoor Air (publishedVersion)
- PubMed (publishedVersion)
- Zenodo (CERN European Organization for Nuclear Research) (submittedVersion, public-domain)
- Funders
- U.S. Department of Energy (DE-AC03-?, AC03-76SF00098, DEAC03-76SF00098)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Keywords
- ventilation rate, CO2 concentration, sick building syndrome, office buildings, institutional building, perceived air quality, respiratory diseases, indoor air quality, occupant health
- MeSH terms
- Adult, Carbon Dioxide, Humans, Public Health, Incidence, Occupational Health, Air Pollution, Indoor, Risk Assessment, Sick Building Syndrome
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review