The DOI matches its Crossref record; 63 of the 64 references it cites were found in a registry or an index.
Association of Ventilation Rates and CO2 Concentrations with Health andOther Responses in Commercial and Institutional Buildings
Open accessAbstract
This paper reviews current literature on the associations of ventilation rates and carbon dioxide concentrations in non-residential and non-industrial buildings (primarily offices) with health and other human outcomes. Twenty studies, with close to 30,000 subjects, investigated the association of ventilation rates with human responses, and 21 studies, with over 30,000 subjects, investigated the association of carbon dioxide concentration with these responses. Almost all studies found that ventilation rates below 10 Ls-1 per person in all building types were associated with statistically significant worsening in one or more health or perceived air quality outcomes. Some studies determined that increases in ventilation rates above 10 Ls-1 per person, up to approximately 20 Ls-1 per person, were associated with further significant decreases in the prevalence of sick building syndrome (SBS) symptoms or with further significant improvements in perceived air quality. The carbon dioxide studies support these findings. About half of the carbon dioxide studies suggest that the risk of sick building syndrome symptoms continued to decrease significantly with decreasing carbon dioxide concentrations below 800 ppm. The ventilation studies reported relative risks of 1.5-2 for respiratory illnesses and 1.1-6 for sick building syndrome symptoms for low compared to high low ventilation rates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Seppänen et al. [14] found that the risk of air-related health problems can be decreased when CO 2 concentrations fall below 800 ppm.”
From Investigation of Indoor Air Quality and the Identification of Influential Factors at Primary Schools in the North of China (2017) · cites this paper as [14]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1979) · Medical Entomology and Zoology · Cited by 11,252
Quasi-experimentation: Design and analysis issues for field settings
Shrout, P. E. (1980) · Evaluation and Program Planning · doi:10.1016/0149-7189(80)90063-4 · Cited by 6,091
Ventilation for Acceptable Indoor Air Quality
Falih, M. (2019) · Cited by 2,497
ASTM Special Technical Publication
Hannula, S., Wanagel, J., & Li, C. Y. (1986) · Cited by 1,225
Estimates of Improved Productivity and Health from Better Indoor Environments
Fisk, W. J., & Rosenfeld, A. H. (1997) · Indoor Air · doi:10.1111/j.1600-0668.1997.t01-1-00002.x · Cited by 551
Self-citationImpact of Temperature and Humidity on the Perception of Indoor Air Quality
Fang, L., Clausen, G., & Fanger, P. O. (1998) · Indoor Air · doi:10.1111/j.1600-0668.1998.t01-2-00003.x · Cited by 534
Risk of Sick Leave Associated with Outdoor Air Supply Rate, Humidification, and Occupant Complaints
Milton, D. K., Glencross, P. M., & WALTERS, M. D. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004212.x · Cited by 364
Apte, M. G., Fisk, W. J., & Daisey, J. M. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004246.x · Cited by 341
Self-citationHEALTH HAZARD EVALUATION REPORT
Reh, C. M., Fleeger, A., & Collins, J. W. (1989) · Cited by 316
Non-Specific Symptoms In Office Workers: A Review And Summary Of The Epidemiologic Literature
Mendell, M. J. (1993) · Indoor Air · doi:10.1111/j.1600-0668.1993.00003.x · Cited by 282
Self-citation
Research works printed but not linked: 37
- ACGIH, 1991, Documentation of the Threshold Limit Values and Biological Exposure Indices, Sixth Edition
- Aizlewood C., 1996, Proceedings of Indoor Air '96, 2, 895
- Apte M., 1999, Indoor CO2 concentrations and sick building syndrome: analysis of the 1994-1996 BASE study data
- Bluyssen P.M., 1995, Proceedings of Healthy Buildings '95, 1287
- Brightman H.S., 1999, Proceedings of Indoor Air '99, 1, 847
- Cochet C., 1995, Proceedings of Healthy Buildings '95, 3, 1359
- Emmerich S., 1999, Proceedings of IAQ '98, 191
- Fanger P.O., 1983, Proceedings of Management of Atmospheres in Tightly Enclosed Spaces, 45
- Fisk WJ., 1992, Proceedings of the 1992 International Symposium on Room Air Convection and Ventilation Effectiveness, 213
- Fisk W., 1998, Proceedings of the 1998 Summer School Study on Energy Efficiency in Buildings, 8.85
- Gamble J., 1986, Proceedings of IAQ 86, 16
- L. Groes (1995 ) "The European IAQ-audit project, Statistical analysis of indoor environmental factors ", Ph.D. thesis, Laboratory of Heating and Air Conditioning, Technical University of Denmark.
- Groes L., 1995, Proceedings of 4th International conference on Healthy Buildings, 1293
- Hall J., 1998, Proceedings of IAQ '98, 171
- Hodgson M.J., 1989, Proceedings of IAQ '89, 8
- Janssen J., 1986, Proceedings of IAQ '86, 161
- Mendell M.J., 1993, Proceedings of Indoor Air '93, 1, 713
- Menzies D., 1993, Proceedings of Indoor Air '93, 6, 551
- Milton D., 1998, American Journal of Respiratory Critical Care Medicine, 157, A647
- Mudarri D., 1997, ASHRAE Transactions, 103, 244
- Myhrvold A., 1996, Proceedings of Indoor Air '96, 4, 369
- Nagda N.L., 1991, Proceedings of IAQ '91, 101
- Nagda N., 1990, Proceedings of Indoor Air '90, 1, 281
- Nardell E.A., 1997, Proceedings of Healthy Buildings '97, 1, 301
- Nelson C.J., 1991, Proceedings of IAQ '91, 14
- Palonen J., 1990, Proceedings of Indoor Air '90, 1, 299
- Persily A., 1997, ASHRAE Transactions, 103, 1
- Persily A., 1987, ASHRAE Transactions, 93, 42
- Roulet C., 1995, Proceedings of 4th International conference on Healthy Buildings, 1299
- Seppanen O., 1999, Proceedings of IAQ '98, 257
- Sieber W., 1998, Proceedings of the Section of Statistics and the Environment, 115
- Smedje G., 1996, Proceedings of Indoor Air '96, 1, 413
- Sohn J-Y, 1994, Proceedings of Healthy Buildings '94, 397
- Sundell J., 1994, Indoor Air, 4, 10.1111/j.1600-0668.1994.tb00031.x · DOI
- Wu X., 1996, Proceedings of Indoor Air '96, 2, 919
- 10.1007/s004200050309 · DOI
- WaRlinder R., 1997, Acta Otolanryngol, 117, 724, 10.3109/00016489709113467 · DOI
Cited by
Sorted by citations
Items 601–700 of 875
Occupational and Public Health Risks
Murawski, J. (2005) · The handbook of environmental chemistry. Volume 4 · doi:10.1007/b107235 · Cited by 5
Indoor Environment in Dwellings and Sick Building Syndrome (SBS) : Longitudinal Studies
Sahlberg, B. (2012) · KTH Publication Database DiVA (KTH Royal Institute of Technology) · Cited by 5
Quantification of the association of ventilation rates with sick building syndrome symptoms
Fisk, W. J., Mirer, A. G., & Mendell, M. J. (2009) · doi:10.2172/962711 · Cited by 5
Self-citationMendell, M. J., USDOE, Indoor Environments Division. Office of Radiation andIndoor Air. Office of Air and Radiation. US Environmental ProtectionAgency DW89939365-01-0 and DW89921695-01-1, Lei-Gomez, Q., Mirer, A. G., Seppanen, O., & Brunner, G. (2006) · doi:10.2172/902452 · Cited by 5
Self-citationA Comparative Analysis of Green Building Certification Systems for Schools
AKYEL, I., Kömürlü, R., & Arditi, D. (2025) · Sustainability · doi:10.3390/su172310491 · Cited by 4
Jäschke, M., Wallburg, F., Weickhardt, C., Satke, P., & Schoenfelder, S. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.113893 · Cited by 4
An evaluation of occupant health and indoor environmental quality in university workspaces
Moayedi, M., & Kamelnia, H. (2022) · Human and Ecological Risk Assessment An International Journal · doi:10.1080/10807039.2022.2146573 · Cited by 4
Kim, D., Min, G., Shin, J., Choe, Y., Choi, K., Sim, S. H., & Yang, W. (2024) · Korean Journal of Environmental Health Sciences · doi:10.5668/jehs.2024.50.1.16 · Cited by 4
Maigari, M., Fu, C., Balodimou, E., Kc, P., Sudhakaran, S., & Sakikhales, M. (2025) · Sustainability · doi:10.3390/su17136155 · Cited by 4
Liu, G., Liu, X., Qin, Z., Gu, Z., Wang, G., Shi, W., Wen, D., Yu, L., Luo, Y., & Xiao, H. (2015) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph120911781 · Cited by 4
Control of Outdoor Ventilation Airflow Rate - Evaluation of Setting Methods
Richieri, F., Salem, T., & Michel, P. (2007) · International Journal of Ventilation · doi:10.1080/14733315.2007.11683778 · Cited by 4
Health-based guideline values for the indoor environment
Dusseldorp, A., van Bruggen, M., Douwes, J. E., Pjcm, J., & Kelfkens, G. (2008) · Rivm Repository (Netherlands National Institute for Public Health and the Environment) · Cited by 4
Embedded Sensing And Actuation For Helmets Co2 Levels Control
Kemp, J., Gaura, E. I., Brusey, J., & Thake, D. (2011) · International Journal on Smart Sensing and Intelligent Systems · doi:10.21307/ijssis-2017-432 · Cited by 4
Qiu, Y., & Ya, T. (2019) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/609/4/042032 · Cited by 4
Andriamamonjy, R., & Klein, R. (2015) · Lirias · Cited by 4
Relationship Between Thermal Sensation and Human Cognitive Performance Based on PMV
Fu, J., Yan, R., Wang, F., & Liang Ma, A. (2020) · Lecture notes in computer science · doi:10.1007/978-3-030-49044-7_4 · Cited by 4
Mitkov, R., Petrova‐Antonova, D., & Hristov, P. O. (2023) · Toxics · doi:10.3390/toxics11080709 · Cited by 5
Measurements and simulation of CO2 concentration in a bedroom of a passive house
Szczepanik-Ścisło, N., & Flaga-Maryańczyk, A. (2018) · Technical Transactions · doi:10.4467/2353737xct.18.139.8978 · Cited by 4
Aduda, K. K., Mocanu, E., Boxem, G., Nguyen, P. H., Kling, W. L., & Zeiler, W. (2014) · International Universities Power Engineering Conference (UPEC) · doi:10.1109/upec.2014.6934623 · Cited by 4
The psychological and physical needs of workers impacting office design
Davies, H. (2010) · Deakin Research Online (Deakin University) · Cited by 4
VENTILATION, ENERGY AND INDOOR AIR QUALITY
Seppänen, O. (2002) · Cited by 4
Menzies, D., & Kreiss, K. (2006) · CRC Press eBooks · doi:10.3109/9780849374531-31 · Cited by 4
Cao, X., Fang, H., & Yuan, X. (2025) · Buildings · doi:10.3390/buildings15173168 · Cited by 4
A Sanitation Argument for Clean Indoor Air: Meeting a Requisite for Safe Public Spaces
Leonardi, A. J., & Mishra, A. K. (2022) · Frontiers in Public Health · doi:10.3389/fpubh.2022.805780 · Cited by 4
Thirunagari, B. K., Garaga, R., & Kota, S. H. (2023) · Current Pollution Reports · doi:10.1007/s40726-023-00271-w · Cited by 4
Prozuments, A., Borodiņecs, A., Ļebedeva, K., & Palcikovskis, A. (2023) · Frontiers in Built Environment · doi:10.3389/fbuil.2023.1258625 · Cited by 3
Sick Building Syndrome Overview- UK’S Indoor Sick Building Syndrome Formation Analysis
Ifeanyi Chukwudi, O. B. I. (2024) · International Journal of Innovative Science and Research Technology (IJISRT) · doi:10.38124/ijisrt/ijisrt24aug1508 · Cited by 3
García-Martín, G., Romero-Lara, F., Campano, M. Á., Acosta, I., & Bustamante, P. (2025) · Applied Sciences · doi:10.3390/app15031217 · Cited by 5
Fuertes, A., Jones, R. V., Larriva, M. T. B., Vergés, R., & Forcada, N. (2025) · Indoor Air · doi:10.1155/ina/4153784 · Cited by 3
“Equivalent” multisensor array based on zirconium doped zinc oxide for indoor environment monitoring
Abayarathne, H. M. I., Gohel, V. R., Simonenko, N. P., Zamansky, K. K., Meng, G., Simonenko, T. L., Zaytsev, V. D., Kondrashov, V., Kottsov, S. Y., Moklokov, A., et al. (2025) · Journal of environmental chemical engineering · doi:10.1016/j.jece.2025.116807 · Cited by 3
Calautit, J. K., Hughes, B. R., O’Connor, D., & Shahzad, S. (2015) · doi:10.5176/2301-394x_ace15.43 · Cited by 3
Real-Time Construction of Thermal Model Based on Multimodal Scene Data
Li, Y., Peng, Q., Lin, J., Peng, Y., Mai, Y., & Liang, S. (2022) · Frontiers in Energy Research · doi:10.3389/fenrg.2022.895534 · Cited by 3
30+ years of knowledge creation: Indoor Air 1991–2021
Nazaroff, W. W. (2022) · Indoor Air · doi:10.1111/ina.13074 · Cited by 3
Patil, V. S., Nandurdikar, V., Shelar, M. N., Barahate, S. D., Pagare, A., & Chandratre, M. (2023) · Sadhana · doi:10.1007/s12046-023-02094-3 · Cited by 3
Redleın, A., Baretschneider, C., & Thrainer, L. (2023) · IOP Conference Series Earth and Environmental Science · doi:10.1088/1755-1315/1176/1/012029 · Cited by 3
Evolution of interior space design criteria on the quality of urban environment: Literature review
Tolacı, S. Ş., Erkan, İ., Diker, F., & Şahin, A. Ş. (2023) · Journal of Design for Resilience in Architecture and Planning · doi:10.47818/drarch.2023.v4i3097 · Cited by 3
Indoor CO 2 phytoremediation using ornamental plants: A case study in Gresik, Indonesia
Tangahu, B. V., Przybysz, A., Mashudi, M., Popek, R., Faz, M. R. I., Titah, H. S., Purwanti, I. F., Pismanik, M., & Mangkoedihardjo, S. (2024) · Ecological Research · doi:10.1111/1440-1703.12511 · Cited by 5
Roy, B., Das, C., Sharma, J., Bhuniya, S., Tiwari, A., Kanungo, S., Karmakar, A., & Chattopadhyay, S. (2024) · Journal of Materials Science Materials in Electronics · doi:10.1007/s10854-024-13557-6 · Cited by 3
Shendell, D. G., Gonzalez, L. N., Panchella, J. A., & Morrell, J. (2021) · Journal of Environmental and Public Health · doi:10.1155/2021/5580616 · Cited by 3
Fuzzy Controller for Indoor Air Quality Control: A Sport Complex Case Study
Omarov, B., Altayeva, A. B., Demeuov, A., Tastanov, A., Kassymbekov, Z., & Koishybayev, A. (2021) · Communications in computer and information science · doi:10.1007/978-981-16-3660-8_5 · Cited by 3
An energy-saving control strategy for VRF and VAV combined air conditioning system in heating mode
Zhu, Y., Jin, X., Du, Z., Fang, X., & Fan, B. (2014) · Purdue e-Pubs (Purdue University System) · Cited by 3
Mendell, M. J., Lei, Q., Apte, M. G., & Fisk, W. J. (2005) · University of North Texas Digital Library (University of North Texas) · Cited by 3
Self-citationModeling and estimation of the humans' effect on the CO2 dynamics inside a conference room
Weekly, K., Bekiaris-Liberis, N. K., & Bayen, A. M. (2014) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc.2014.7039561 · Cited by 3
Air quality as an important indicator for ergonomic offices and school premises
Traumann, A., Kritševskaja, M., Tint, P., & Klauson, D. (2014) · Agronomy Research · Cited by 3
Effects of ERV Filter Degradation on Indoor CO2 Levels of a Classroom
Choi, J.-S., Lee, J., & Kim, E.-J. (2018) · Sustainability · doi:10.3390/su10041215 · Cited by 3
DEMAND RESPONSE OF SPACE HEATING AND VENTILATION – IMPACT ON INDOOR ENVIRONMENTAL QUALITY
Martin, K., Jokisalo, J., Kosonen, R., & Vand, B. (2018) · Aaltodoc (Aalto University) · Cited by 3
Sarigiannis, D. A. (2014) · Springer eBooks · doi:10.1007/978-94-017-9499-2_46 · Cited by 3
Apte, M. G., Bourassa, N. J., Faulkner, D. M., Hodgson, A. T., Hotchi, T., Spears, M., Sullivan, D. P., & Wang, D. (2008) · doi:10.2172/927880 · Cited by 3
Aljeesh, Y. I., Madhoun, W. A., Shamh, I. A., & Arcaya, M. (2016) · Cited by 3
Mendell, M. J., & Fisk, W. J. (2014) · doi:10.2172/1164281 · Cited by 3
Self-citationMelhado, M. M. (2012) · TU/e Research Portal · doi:10.6100/ir734694 · Cited by 3
Energy use and indoor environment in new and existing dwellings in Arctic climates
Kotol, M. (2014) · Cited by 3
Thermal Analysis of Hollow Core Ventilated Slab Systems
Park, B. (2016) · CU Scholar (University of Colorado Boulder) · Cited by 3
Mendell, M. J., USDOE. Indoor Environments Division. Office of Radiation andIndoor Air, O. O. A. A. R. O. T. U. S. E. A. T. I. A.-1., Mirer, A. G., & Lei-Gomez, Q. (2007) · doi:10.2172/928793 · Cited by 3
Self-citationINDOOR AIR QUALITY IN NONINDUSTRIAL OCCUPATIONAL ENVIRONMENTS
Morey, P. R., & Shaughnessy, R. J. (2019) · doi:10.1002/9781119581482.ch8 · Cited by 3
Improving Indoor Air Quality in a Higher-Education Institution Through Biophilic Solutions
Gomes, M. I., Barreiros, A. M., Pinto, I., & Rodrigues, A. (2025) · Sustainability · doi:10.3390/su17115041 · Cited by 2
Vestfal, P., & Šeduikytė, L. (2025) · Buildings · doi:10.3390/buildings15234341 · Cited by 2
Li, G., Zdarta, J., Jesionowski, T., & Zdarta, A. (2026) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6c01406 · Cited by 2
Moltedo-Medina, J., Trebilcock, M., Rubio-Bellido, C., & Pérez-Fargallo, A. (2026) · Buildings · doi:10.3390/buildings16101943 · Cited by 2
Field study on economic impact of the working environments in non-temperate climates
Ahmed, R. (2014) · WIT transactions on ecology and the environment · doi:10.2495/eid140141 · Cited by 2
Bozkurt, S., & Bozkurt, S. (2023) · Global Challenges · doi:10.1002/gch2.202300120 · Cited by 2
Rajagopalan, P., Woo, J., & Andamon, M. M. (2024) · Journal of Architectural Engineering · doi:10.1061/jaeied.aeeng-1700 · Cited by 2
Bier, H., Hidding, A., Khademi, S., van Engelenburg, C., Alavi, H. S., & Zhong, S. (2024) · Technology|Architecture + Design · doi:10.1080/24751448.2024.2322927 · Cited by 2
Matthews, J. C., Khan, M. A. H., Wright, M., Perumal, P. K., Percival, C. J., Bull, I. D., Craddock, I. J., & Shallcross, D. E. (2024) · Indoor Air · doi:10.1155/2024/9204433 · Cited by 3
Chen, C. O., Chen, J., Chio, C., Chen, P., Su, T., & Chan, C. (2024) · Indoor Air · doi:10.1155/2024/1779971 · Cited by 2
A Low-cost Monitoring System for Enhanced Indoor Air Quality inside Built environment
Shriram, S. (2024) · IEEE Conference on Engineering Informatics (ICEI) · doi:10.1109/icei64305.2024.10912089 · Cited by 2
López-Carreño, R.-D., Pardo-Bosch, F., Aidarov, S., Boix‐Cots, D., & Pujadas, P. (2025) · Applied Sciences · doi:10.3390/app15074033 · Cited by 2
Ruangsuwan, T., Phanprasit, W., Yoosook, W., Boonyayothin, V., Konthonbut, P., Cherrie, J. W., & Nankongnab, N. (2025) · Buildings · doi:10.3390/buildings15081313 · Cited by 2
Measuring Elevated Indoor Carbon Dioxide Concentration from Unsuitable Condition of Indoor Plant
Pamonpol, K., Tokhun, N., & Somparn, A. (2020) · International Conference and Utility Exhibition on Energy, Environment and Climate Change (ICUE) · doi:10.1109/icue49301.2020.9307080 · Cited by 2
Effect of Closed Building Syndrome on Pulmonary Function
IBRAHIM, M. S. H. E. O. M. S. S., & AMIN, Y. M. (2021) · The Medical Journal of Cairo University/The Medical Journal of Cairo University · doi:10.21608/mjcu.2021.153779 · Cited by 2
Guzenberg, A. S., Викторович, Ю. А., Romanov, S. J., Григорьевич, Ж. А., & Burlakova, A. A. (2021) · Manned Spaceflight · doi:10.34131/msf.21.2.35-59 · Cited by 2
Air Quality as a Key Factor in the Aromatisation of Stores: A Systematic Literature Review
Panovská, Z., Ilko, V., & Doležal, M. (2021) · Applied Sciences · doi:10.3390/app11167697 · Cited by 2
PARTİKÜL MADDE, KARBON MONOKSİT VE KARBONDİOKSİT SEVİYELERİNİN İÇ VE DIŞ ORTAMLARDA DEĞİŞİMİ
Menteşe, S., & Çotuker, O. (2021) · Mühendislik Bilimleri ve Tasarım Dergisi · doi:10.21923/jesd.811053 · Cited by 2
Mendell, M. J., Lei-Gomez, Q., Cozen, M., Brightman, H. S., Apte, M. G., Erdmann, C. A., Brunner, G., & Girman, J. R. (2006) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · Cited by 2
Self-citationFisk, W. J., Faulkner, D. M., & Sullivan, D. P. (2008) · University of North Texas Digital Library (University of North Texas) · Cited by 2
Self-citationEnergy performance and indoor air quality in modern buildings in Greenland—Case study Apisseq
Kotol, M., Rode, C., & Vahala, J. (2015) · Science and Technology for the Built Environment · doi:10.1080/23744731.2015.1012418 · Cited by 2
Indoor environment quality and sustainable development for commercial buildings in Australia
Aye, L., Charters, W. W. S., Chiazor, M., & Robinson, J. (2004) · Swinburne figshare (Swinburne University of Technology) · Cited by 2
MODELING OF INDOOR AIR QUALITY
Teodosiu, C. I. (2011) · International Multidisciplinary Scientific GeoConference SGEM ... · doi:10.5593/sgem2015/b41/s19.125 · Cited by 2
SMART BUILDINGS FOR HEALTHY AND SUSTAINABLE WORKPLACES: SCOPING STUDY REPORT
Foliente, G., Paevere, P. J., & Bell, J. M. (2003) · Cited by 2
Effects of inhalation exposure to carbon dioxide on human health in indoor environment
Azuma, K. (2018) · Indoor Environment · doi:10.7879/siej.21.113 · Cited by 2
Indoor air quality investigation in a ventilated demonstrator building via a smart sensor
Qabbal, L., Younsi, Z., & Naji, H. (2020) · International Journal of Ventilation · doi:10.1080/14733315.2020.1786974 · Cited by 2
Sustainable and Healthy Built Environment
Loftness, V., & Snyder, M. (2020) · Springer eBooks · doi:10.1007/978-1-0716-0684-1_197 · Cited by 2
The Study on Association between Urban Green Space and Temperature Changes in Mega City
Padon, A., Punson, B., Iamtrakul, P., & Klaylee, J. (2020) · International Conference and Utility Exhibition on Energy, Environment and Climate Change (ICUE) · doi:10.1109/icue49301.2020.9307077 · Cited by 2
An investigation concerning optimal design of confluent jets ventilation with variable air volume
Andersson, H., Cehlin, M., & Moshfegh, B. (2024) · International Journal of Ventilation · doi:10.1080/14733315.2023.2300231 · Cited by 2
A Novel Soundproof Ventilation Plant Design with High Performance and No Energy Consumption
Yu, Y., Chao, Y.-T., Lee, L.-C., Yen, J., & Fan, Y.-C. (2015) · Mathematical Problems in Engineering · doi:10.1155/2015/496748 · Cited by 2
Fauchoux, M. T., Simonson, C. J., Torvi, D. A., Eldeeb, R., & Ojanen, T. (2014) · Building pathology and rehabilitation · doi:10.1007/978-3-319-04531-3_8 · Cited by 2
Lestinen, S., Kilpeläinen, S., Kosonen, R., & Jokisalo, J. (2021) · E3S Web of Conferences · doi:10.1051/e3sconf/202124611003 · Cited by 2
Hart, K. M. (2011) · Dublin City University Open Access Institutional Repository (Dublin City University) · Cited by 2
Fisk, W. J., (US), U. A. S. F. E. E. A. R. E. W. A. I. P., Sullivan, D., & Faulkner, D. M. (2005) · doi:10.2172/925417 · Cited by 2
Self-citationDemand controlled ventilation and classroom ventilation
Lawrence Berkeley National Lab. (LBNL), B., Fisk, W., Building Technologies Office (EE-5B) USDOE Office of Energy Efficiency and Renewable Energy (EERE), Mendell, M., Davies, M., Eliseeva, E. A., Faulkner, D., Hong, T., & Sullivan, D. P. (2014) · doi:10.2172/1127147 · Cited by 2
Self-citationScientific Basis for Swedish Occupational Standards XXXII
Montelius, J. (2013) · Gothenburg University Publications Electronic Archive (Gothenburg University) · Cited by 2
Kermeci, P. (2018) · UEA Digital Repository (University of East Anglia) · Cited by 2
Transforming thermal comfort model and control in the tropics : a machine-learning approach
Hu, W. (2020) · doi:10.32657/10356/141578 · Cited by 2
Oelßner, W. (2019) · doi:10.1002/9783527688302.ch13 · Cited by 2
Indoor Air Quality in Elderly Care Centers: A Multidisciplinary ApproachPreprint
Seseña, S., Valiente, N., Rodríguez-Pérez, M., Rodrı́guez, A., & Palop, M. L. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4809979 · Cited by 2
Design and Performance Evaluation of an Advanced HVAC System for Health and Comfort in AARCPreprint
Tang, X., Xu, W., & Peng, M. (2024) · Research Square · doi:10.21203/rs.3.rs-4825873/v1 · Cited by 2
Kim, J. (2006) · KTH Publication Database DiVA (KTH Royal Institute of Technology) · Cited by 2
Using a DS-DBR laser for widely tunable near-infrared cavity ring-down spectroscopy
Whittaker, K. E., Ciaffoni, L., Hancock, G., Hurst, P. L., Peverall, R., & Ritchie, G. A. D. (2013) · Applied Physics B · doi:10.1007/s00340-013-5667-z · Cited by 1
Zhou, K., Ma, S., Shao, X., Li, S., & Jin, Q. (2024) · Building Services Engineering Research and Technology · doi:10.1177/01436244241239284 · Cited by 1
Metadata
- Authors
- Seppanen, O. A., Fisk, W. J., & Mendell, M. J.
- Affiliations
- Lawrence Berkeley National Laboratory (US)
- National Institute for Occupational Safety and Health (US)
- Corresponding author
- Fisk, W. J.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 1999-12
- Volume
- 9
- Issue
- 4
- Pages
- 226-252
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W2161463298
- Cited by
- 876
- References
- 64
- Citations by year
- 2026: 41 · 2025: 45 · 2024: 36 · 2023: 46 · 2022: 48 · 2021: 53 · 2020: 74 · 2019: 56 · 2018: 45 · 2017: 32 · 2016: 31 · 2015: 52 · 2014: 51 · 2013: 29 · 2012: 38
- FWCI
- 2.63
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Indoor Air (publishedVersion)
- PubMed (publishedVersion)
- Zenodo (CERN European Organization for Nuclear Research) (submittedVersion, public-domain)
- Funders
- U.S. Department of Energy (DE-AC03-?, AC03-76SF00098, DEAC03-76SF00098)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Keywords
- ventilation rate, CO2 concentration, sick building syndrome, office buildings, institutional building, perceived air quality, respiratory diseases, indoor air quality, occupant health
- MeSH terms
- Adult, Carbon Dioxide, Humans, Public Health, Incidence, Occupational Health, Air Pollution, Indoor, Risk Assessment, Sick Building Syndrome
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review