Association of Ventilation Rates and CO2 Concentrations with Health andOther Responses in Commercial and Institutional Buildings
Open accessAbstract
This paper reviews current literature on the associations of ventilation rates and carbon dioxide concentrations in non-residential and non-industrial buildings (primarily offices) with health and other human outcomes. Twenty studies, with close to 30,000 subjects, investigated the association of ventilation rates with human responses, and 21 studies, with over 30,000 subjects, investigated the association of carbon dioxide concentration with these responses. Almost all studies found that ventilation rates below 10 Ls-1 per person in all building types were associated with statistically significant worsening in one or more health or perceived air quality outcomes. Some studies determined that increases in ventilation rates above 10 Ls-1 per person, up to approximately 20 Ls-1 per person, were associated with further significant decreases in the prevalence of sick building syndrome (SBS) symptoms or with further significant improvements in perceived air quality. The carbon dioxide studies support these findings. About half of the carbon dioxide studies suggest that the risk of sick building syndrome symptoms continued to decrease significantly with decreasing carbon dioxide concentrations below 800 ppm. The ventilation studies reported relative risks of 1.5-2 for respiratory illnesses and 1.1-6 for sick building syndrome symptoms for low compared to high low ventilation rates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Seppänen et al. [14] found that the risk of air-related health problems can be decreased when CO 2 concentrations fall below 800 ppm.”
From Investigation of Indoor Air Quality and the Identification of Influential Factors at Primary Schools in the North of China (2017) · cites this paper as [14]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1979) · Medical Entomology and Zoology · Cited by 11,252
Quasi-experimentation: Design and analysis issues for field settings
Shrout, P. E. (1980) · Evaluation and Program Planning · doi:10.1016/0149-7189(80)90063-4 · Cited by 6,091
Ventilation for Acceptable Indoor Air Quality
Falih, M. (2019) · Cited by 2,497
ASTM Special Technical Publication
Hannula, S., Wanagel, J., & Li, C. Y. (1986) · Cited by 1,225
Estimates of Improved Productivity and Health from Better Indoor Environments
Fisk, W. J., & Rosenfeld, A. H. (1997) · Indoor Air · doi:10.1111/j.1600-0668.1997.t01-1-00002.x · Cited by 551
Self-citationImpact of Temperature and Humidity on the Perception of Indoor Air Quality
Fang, L., Clausen, G., & Fanger, P. O. (1998) · Indoor Air · doi:10.1111/j.1600-0668.1998.t01-2-00003.x · Cited by 534
Risk of Sick Leave Associated with Outdoor Air Supply Rate, Humidification, and Occupant Complaints
Milton, D. K., Glencross, P. M., & WALTERS, M. D. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004212.x · Cited by 364
Apte, M. G., Fisk, W. J., & Daisey, J. M. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004246.x · Cited by 341
Self-citationHEALTH HAZARD EVALUATION REPORT
Reh, C. M., Fleeger, A., & Collins, J. W. (1989) · Cited by 316
Non-Specific Symptoms In Office Workers: A Review And Summary Of The Epidemiologic Literature
Mendell, M. J. (1993) · Indoor Air · doi:10.1111/j.1600-0668.1993.00003.x · Cited by 282
Self-citation
Research works printed but not linked: 37
- ACGIH, 1991, Documentation of the Threshold Limit Values and Biological Exposure Indices, Sixth Edition
- Aizlewood C., 1996, Proceedings of Indoor Air '96, 2, 895
- Apte M., 1999, Indoor CO2 concentrations and sick building syndrome: analysis of the 1994-1996 BASE study data
- Bluyssen P.M., 1995, Proceedings of Healthy Buildings '95, 1287
- Brightman H.S., 1999, Proceedings of Indoor Air '99, 1, 847
- Cochet C., 1995, Proceedings of Healthy Buildings '95, 3, 1359
- Emmerich S., 1999, Proceedings of IAQ '98, 191
- Fanger P.O., 1983, Proceedings of Management of Atmospheres in Tightly Enclosed Spaces, 45
- Fisk WJ., 1992, Proceedings of the 1992 International Symposium on Room Air Convection and Ventilation Effectiveness, 213
- Fisk W., 1998, Proceedings of the 1998 Summer School Study on Energy Efficiency in Buildings, 8.85
- Gamble J., 1986, Proceedings of IAQ 86, 16
- L. Groes (1995 ) "The European IAQ-audit project, Statistical analysis of indoor environmental factors ", Ph.D. thesis, Laboratory of Heating and Air Conditioning, Technical University of Denmark.
- Groes L., 1995, Proceedings of 4th International conference on Healthy Buildings, 1293
- Hall J., 1998, Proceedings of IAQ '98, 171
- Hodgson M.J., 1989, Proceedings of IAQ '89, 8
- Janssen J., 1986, Proceedings of IAQ '86, 161
- Mendell M.J., 1993, Proceedings of Indoor Air '93, 1, 713
- Menzies D., 1993, Proceedings of Indoor Air '93, 6, 551
- Milton D., 1998, American Journal of Respiratory Critical Care Medicine, 157, A647
- Mudarri D., 1997, ASHRAE Transactions, 103, 244
- Myhrvold A., 1996, Proceedings of Indoor Air '96, 4, 369
- Nagda N.L., 1991, Proceedings of IAQ '91, 101
- Nagda N., 1990, Proceedings of Indoor Air '90, 1, 281
- Nardell E.A., 1997, Proceedings of Healthy Buildings '97, 1, 301
- Nelson C.J., 1991, Proceedings of IAQ '91, 14
- Palonen J., 1990, Proceedings of Indoor Air '90, 1, 299
- Persily A., 1997, ASHRAE Transactions, 103, 1
- Persily A., 1987, ASHRAE Transactions, 93, 42
- Roulet C., 1995, Proceedings of 4th International conference on Healthy Buildings, 1299
- Seppanen O., 1999, Proceedings of IAQ '98, 257
- Sieber W., 1998, Proceedings of the Section of Statistics and the Environment, 115
- Smedje G., 1996, Proceedings of Indoor Air '96, 1, 413
- Sohn J-Y, 1994, Proceedings of Healthy Buildings '94, 397
- Sundell J., 1994, Indoor Air, 4, 10.1111/j.1600-0668.1994.tb00031.x · DOI
- Wu X., 1996, Proceedings of Indoor Air '96, 2, 919
- 10.1007/s004200050309 · DOI
- WaRlinder R., 1997, Acta Otolanryngol, 117, 724, 10.3109/00016489709113467 · DOI
Cited by
Sorted by citations
Items 701–800 of 875
Field Investigation on the Thermal Environment and Comfort of People Exercising in a Fitness Center
Wang, H., Hao, Y., Lin, H., Hou, R., & Gong, K. (2024) · Buildings · doi:10.3390/buildings14103296 · Cited by 1
Kumari, N., Sahu, V., Chintala, K., M., S. C., Durga, C. S., Mantravadi, H. B., Peddapalegani, P., & Ealla, K. K. R. (2025) · Bulletin of Atmospheric Science and Technology · doi:10.1007/s42865-025-00092-3 · Cited by 1
Gu, Y., Zhuang, W., Zhong, K., & Yang, Z. (2025) · Indoor and Built Environment · doi:10.1177/1420326x251344138 · Cited by 1
Iwayama, R., Shimatani, K., Nakayama, Y., Takaguchi, K., Nakaoka, H., Suzuki, N., & Sakurai, K. (2025) · Buildings · doi:10.3390/buildings15173013 · Cited by 1
Alhindawi, I., Fernandes, J. M., Sood, D., O’Donnell, J., & Byrne, M. A. (2026) · Journal of Building Engineering · doi:10.1016/j.jobe.2026.115257 · Cited by 1
Zhou, K., Leng, J., Zhou, X., Zhou, K., & Zhao, J. (2026) · Building Simulation · doi:10.1007/s12273-025-1388-6 · Cited by 1
İlgördü, Ö. Ö., & Başak, S. (2026) · Environments · doi:10.3390/environments13020099 · Cited by 1
Heß, D., Rubin, M., & Dittmeyer, R. (2026) · Journal of CO2 Utilization · doi:10.1016/j.jcou.2026.103351 · Cited by 1
Meiss, A., Montaluisa-Mantilla, M. S., Guerra-Díez, D., Poza-Casado, I., & Muñoz, R. (2026) · Results in Engineering · doi:10.1016/j.rineng.2026.110018 · Cited by 1
Fosu-Amankwah, K., Owusu, S., Mensah, P. K., Asamoah, E., & Damoah, R. (2026) · African Transport Studies · doi:10.1016/j.aftran.2026.100088 · Cited by 1
Park, S.-Y., Ceong, J.-Y., Noh, K., Kim, J.-S., & Lee, C.-M. (2025) · Journal of Odor and Indoor Environment · doi:10.15250/joie.2025.24.4.367 · Cited by 1
Ventilation Rate Estimation and Analysis in Schools
Clinchard, S., Haverinen‐Shaughnessy, U., & Shaughnessy, R. J. (2026) · Lecture notes in civil engineering · doi:10.1007/978-3-032-10546-2_137 · Cited by 1
Maroofiazar, R., & Reveshti, A. M. (2026) · Indoor Air · doi:10.1155/ina/9959278 · Cited by 2
Sustainable and Healthy Built Environment
Loftness, V., & Snyder, M. (2013) · Springer eBooks · doi:10.1007/978-1-4614-5828-9_197 · Cited by 1
Indoor air quality in junior high schools in Reykjavík
Hellsing, V. Ú. L. (2009) · Cited by 1
A review of the scope of scientific studies relating indoor environment and student performance
Davies, H., & Lee, H. (2007) · Cited by 1
Liu, L. R., Wu, J., Wang, X. X., Li, Z. S., & Cheng, T. J. (2012) · Applied Mechanics and Materials · doi:10.4028/www.scientific.net/amm.260-261.391 · Cited by 1
Assessment of carbon rating in Kinnaird College for women Lahore, Pakistan
Aslam, A. (2013) · International Journal on Environmental Sciences · Cited by 1
Maddalena, R. L. (2014) · eScholarship (California Digital Library) · Cited by 1
Proposed Procedure to Design an Optimum Ventilation System for Chemical Laboratory
Abdoon, G. I., & Bashir, N. F. (2017) · Advances in Chemical Engineering and Science · doi:10.4236/aces.2017.73024 · Cited by 1
INDOOR AIR QUALITY MODELLING ON UNIVERSITY BUILDINGS IN TABASCO, MEXICO
Villegas, E. M., Ramos-Herrera, S., SALVADOR-TORRES, I. I., Velueta, J. M. C., & Bautista-Margulis, R. G. (2018) · WIT transactions on ecology and the environment · doi:10.2495/air180281 · Cited by 1
Pengpom, N., Vongpradubchai, S., & Rattanadecho, P. (2019) · International Journal of Heat and Technology · doi:10.18280/ijht.370237 · Cited by 1
Redleın, A., & Thrainer, L. (2022) · Conference on Human System Interactions · doi:10.1109/hsi55341.2022.9869468 · Cited by 1
Agendas Locais e Globais da Sustentabilidade: Ciência, Tecnologia, Gestão e Sociedade
Paulino, S. R., Christopoulos, T. P., Duleba, W., Igari, A. T., & de Almeida, P. S. (2022) · Editora Blucher eBooks · doi:10.5151/9786555501551 · Cited by 1
Fungal Exposure and Shelter Assessment in Syrian Refugee Settlements in Lebanon
Alaouie, M., Troisi, G. M., Saliba, N. A., Shaib, H. A., Hajj, R., Hajj, R. E., Malak, S., Jakarian, C., & Jaafar, W. (2023) · Aerobiology · doi:10.3390/aerobiology1010003 · Cited by 1
Evaluation of Indoor Air Quality in Residential Spaces During COVID-19 in Bahrain
Job, S. R. A. (2023) · Environment and Ecology Research · doi:10.13189/eer.2023.110505 · Cited by 1
APROVECHAMIENTO DEL CO2 EXHALADO PARA EL CRECIMIENTO DE CULTIVOS EN ENTORNOS URBANOS
Alegría-Sala, A., Ruana-Jornet, F., Casals, L. C., & Macarulla, M. (2023) · Proceedings · doi:10.61547/3439 · Cited by 1
Tripathi, S., Pandey, N. K., Verma, V., & Mishra, N. (2025) · Materials Science and Engineering B · doi:10.1016/j.mseb.2025.119112 · Cited by 1
Fadeyi, M. O. (2012) · Cited by 1
Li, S. (2014) · Journal of Energy Engineering · doi:10.1061/(asce)ey.1943-7897.0000201 · Cited by 1
Urban Air Quality Management: Detecting and Improving Indoor Ambient Air Quality
Tan, T. L., & Lebron, G. B. (2011) · Springer eBooks · doi:10.1007/978-94-007-0383-4_13 · Cited by 1
Associations of Indoor CO2 Concentration with Sleep Quality and Other Human Responses
Luo, G., Zhang, X., Xie, J., & Li, D. (2020) · Environmental science and engineering · doi:10.1007/978-981-13-9520-8_99 · Cited by 1
Exergy analysis of day light using fuzzy logic controllers of Jordanian commercial buildings
Baniyounes, A. M., Ghadi, Y. Y., & Alnabulsi, M. (2020) · International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering · doi:10.11591/ijpeds.v11.i4.pp1686-1692 · Cited by 1
Durability, condensation assessment and prevention
Brambilla, A., & Sangiorgio, A. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-821097-0.00006-0 · Cited by 1
Iyengar, R. (2014) · Repository for Publications and Research Data (ETH Zurich) · doi:10.3929/ethz-a-010265196 · Cited by 1
Application of Microfibrous Materials in Air Filtration for Improving Indoor Air Quality
Chen, Y. (2012) · Cited by 1
Improving Ventilation and Saving Energy: Laboratory Study in aModular Classroom Test Bed
Apte, M. G., USDOE. Assistant Secretary for Energy Efficiency andRenewable Energy. Office of the Deputy Assistant Secretary for TechnologyDevelopment. Office of the Building Technologies Program, Buchanan, I., Faulkner, D., Fisk, W., Lai, C.-M., Spears, M., & Sullivan, D. P. (2005) · doi:10.2172/861971 · Cited by 1
Self-citationMeasuring Outdoor Air Intake Rates into Existing Building
Fisk, W. J., Sullivan, D. P., Cohen, S., & Han, H. (2009) · doi:10.2172/994011 · Cited by 1
Self-citationIndoor and Outdoor Air Pollution in Relation to Allergy and Asthma in Taiyuan, China
Zhao, Z. (2006) · KTH Publication Database DiVA (KTH Royal Institute of Technology) · Cited by 1
Between Scylla and Charybdis: energy, carbon dioxide, and indoor environmental quality
Nazaroff, W. W. (2013) · Indoor Air · doi:10.1111/ina.12051 · Cited by 1
Editorial: IAQ and Sustainability—A Balancing Act
Sekhar, C. (2009) · Science and Technology for the Built Environment · doi:10.1080/10789669.2009.10390875 · Cited by 1
The effects of simulated lifeboat motions on carbon dioxide production
Aylward, K. A. (2015) · Memorial University Research Repository (Memorial University) · Cited by 1
Sustainable and Healthy Built Environment
Loftness, V., & Snyder, M. (2012) · Springer eBooks · doi:10.1007/978-1-4419-0851-3_197 · Cited by 1
Liu, Y., Zhao, M., Shao, Y., Yan, L., & Zhu, X. (2020) · doi:10.21203/rs.2.20593/v1 · Cited by 1
Güney, H., SAADA, B., Sarı, B., & Keskinkan, O. (2023) · Research Square · doi:10.21203/rs.3.rs-2651063/v1 · Cited by 1
Multi-zone Demand-controlled Ventilation in Residential Buildings : An experimental case study
Hesaraki, A., Myhren, J. A., & Holmberg, S. (2014) · KTH Publication Database DiVA (KTH Royal Institute of Technology)
Fisk, W. J., Office of the Building Technologies Program USDOE. Assistant Secretary for Energy Efficiency and Renewable Energy, Price, P. N., Faulkner, D., Sullivan, D., & DiBartolomeo, D. L. (2003) · doi:10.2172/836796
Self-citationIndoor Environment and Energy Efficiency in Higher Schools
Dias, M. J. (2011) · doi:10.14201/gredos.110820
THE RELATIONSHIP BETWEEN THE DIABETIC PATIENTS AND THE BUILT ENVIRONMENT: THE ISLAMIC VIEW
Sidawi, B., & Al-Hariri, M. T. (2001) · Journal of Islamic Architecture · doi:10.18860/jia.v2i2.2203
Calautit, J. K., Hughes, B. R., O’Connor, D., & Shahzad, S. (2015)
Improvement of the Illumination Levels Combined with Energy Savings for a Residential Building
Abdul-Wahab, S. A., & Ahmed, S. U. (2011) · Springer eBooks · doi:10.1007/978-3-642-17919-8_26
Demand Controlled Ventilation: Use in Calgary and Impact of Sensor Location
Lachapelle, A.-C. (2012) · Libraries and Cultural Resources (University of Calgary) · doi:10.11575/prism/25548
Indoor environments : design, productivity and health
Bell, J. (2004) · QUT ePrints (Queensland University of Technology)
Improving Ventilation and Saving Energy: Relocatable ClassroomField Study Interim Report
Apte, M. G., USDOE. Assistant Secretary for Energy Efficiency andRenewable Energy. Office of the Deputy Assistant Secretary for TechnologyDevelopment. Office of the Building Technologies Program, Buchanan, I., Faulkner, D., Hotchi, T., Spears, M., Sullivan, D., & Wang, D. (2005) · doi:10.2172/860386
Sharma, R. R., Bharti, O. C., & Kumar, D. (2007)
Guerra, S. P. (2012) · KU ScholarWorks (The University of Kansas)
Rim, D. (2009) · Texas ScholarWorks (Texas Digital Library)
McLeod, J. D. (2008) · OhioLink ETD Center (Ohio Library and Information Network)
VENTILATION FOR BUILDINGS: DESIGN CRITERIA FOR THE IN- DOOR ENVIRONMENT - A NEW INITIATIVE
Meier, S., Lommel, A., & Kegel, B. (2000)
Review of Literature Related to Residential Ventilation Requirements
Lawrence, E. O., Mcwilliams, J., & Sherman, M. (2013)
A PILOT STUDY OF THE ACCURACY OF CO2 SENSORS IN
Faulkner, D. M., & Sullivan, D. P. (2007)
Environmental Health: A Global Access Science Source
Myatt, T. A., STAUDENMAYER, J. W., Adams, K., Walters, M. D., Rudnick, S. N., & Milton, D. K. (2002)
Improvement of indoor climate in an educational building
Kletchenko, E. (2015) · Theseus (Ammattikorkeakoulujen)
A Prospective Study of Ventilation Rates and Illness Absence in California Office Buildings
Eliseeva, E. A., Spears, M., Chan, W. R., Cohn, S., Sullivan, D. P., & Fisk, W. J. (2014) · eScholarship (California Digital Library)
Self-citationRhee, K.-N. (2015) · Indoor and Built Environment · doi:10.1177/1420326x15595449
The Work Ability and Social Inclusion (WASI) Project
Surakka, J. (2014) · Theseus (Ammattikorkeakoulujen)
Improvement of Workplace Ergonomics in Atrium-Type Buildings
Tint, P., Hrenov, G., Siirak, V., Traumann, A., Krichevskaya, M., & Klauson, D. (2016) · Proceedings of the Latvian Academy of Sciences Section B Natural Exact and Applied Sciences · doi:10.1515/prolas-2016-0051
Szczurek, A., Maciejewska, M., & Pietrucha, T. (2015) · Environment Protection Engineering · doi:10.37190/epe150313
Low Power System Design for Emerging Pervasive Platforms
Li, K. (2014) · CU Scholar (University of Colorado Boulder)
Risk Factors in Heating, Ventilating, and Air-Conditioning Systems for Occupant Symptoms in
Mendell, M. J., Lei-Gomez, Q., Mirer, A. G., Seppänen, O., & Brunner, G. (2007) · eScholarship (California Digital Library)
Self-citationLeung, M. H., Sciences, E. H. B. S. O. H., & Sidhu, B. (2015) · BCIT Environmental Public Health Journal · doi:10.47339/ephj.2015.113
Investigating the indoor air quality of common library study spaces in an Australian university
Loh, Y. S. J., Andamon, M. M., & Wong, J. P. C. (2017) · RMIT Research Repository (RMIT University Library)
Minimising Excessive Energy Consumption in Schools While Maintaining Optimal Air Quality
Hallin, S. (2017) · Open Journal of Optimization · doi:10.4236/ojop.2017.64010
Elharidi, A. M. (2017) · STAX · doi:10.48730/5p2y-vb18
Dovjak, M., & Kukec, A. (2019) · Springer eBooks · doi:10.1007/978-3-030-19412-3_4
Measurements of Ambient Particle Material Level in Shopping Centers in Konya City
Qasim, M. N., & Dursun, Ş. (2019) · International Journal of Environmental Pollution and Environmental Modelling
Comparison between Some Wind-catchers and Its Effect in Natural Ventilation: Case Study
Ahmadi, M., & Zhao, K. (2021) · Urban Studies and Public Administration · doi:10.22158/uspa.v4n1p23
Repurposing CO2 from Human Respiration Inside Buildings to Enhance Growth in Rooftop GardensPreprint
Buckley, S., Sparks, R., Marsching, J., & Phillips, N. G. (2021) · Research Square · doi:10.21203/rs.3.rs-163704/v1
Evaluation of Exposure to Tuberculosis Among Immigration Employees
de Perio, M. A., & Niemeier, R. T. (2010)
Contaminants in Buildings and Occupied Spaces as Risk Factors for Occupant Symptoms in U.S.
Mendell, M. J., Mirer, A. G., & Lei-Gomez, Q. (2008) · eScholarship (California Digital Library)
Self-citationNord, L. O., & Bolland, O. (2020) · doi:10.1002/9783527826667.refs
Kampelis, N., & Kolokotsa, D. D. (2022) · doi:10.1002/9781119902201.refs
(2018) · AUSTRALIAN JOURNAL OF BASIC AND APPLIED SCIENCES · doi:10.22587/ajbas.2018.12.12.4
Sustainable and Healthy Built Environment
Loftness, V., & Snyder, M. (2017) · Springer eBooks · doi:10.1007/978-1-4939-2493-6_197-3
Evaluation Of Functional Capacity in Asymptomatic School Teacher Using 6 Minute Walk Test
Sequeira, R. (2020) · Indian Journal of Physiotherapy and Occupational Therapy - An International Journal · doi:10.37506/ijpot.v14i2.2639
Global Journal of Health Science, Vol. 1, No. 2, October 2009, all in one file.
Editor, G. J. H. S. (2009) · Global Journal of Health Science · doi:10.5539/gjhs.v1n2p0 · Cited by 1
Metadata
- Authors
- Seppanen, O. A., Fisk, W. J., & Mendell, M. J.
- Affiliations
- Lawrence Berkeley National Laboratory (US)
- National Institute for Occupational Safety and Health (US)
- Corresponding author
- Fisk, W. J.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 1999-12
- Volume
- 9
- Issue
- 4
- Pages
- 226-252
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W2161463298
- Cited by
- 876
- References
- 64
- Citations by year
- 2026: 41 · 2025: 45 · 2024: 36 · 2023: 46 · 2022: 48 · 2021: 53 · 2020: 74 · 2019: 56 · 2018: 45 · 2017: 32 · 2016: 31 · 2015: 52 · 2014: 51 · 2013: 29 · 2012: 38
- FWCI
- 2.63
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Indoor Air (publishedVersion)
- PubMed (publishedVersion)
- Zenodo (CERN European Organization for Nuclear Research) (submittedVersion, public-domain)
- Funders
- U.S. Department of Energy (DE-AC03-?, AC03-76SF00098, DEAC03-76SF00098)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Keywords
- ventilation rate, CO2 concentration, sick building syndrome, office buildings, institutional building, perceived air quality, respiratory diseases, indoor air quality, occupant health
- MeSH terms
- Adult, Carbon Dioxide, Humans, Public Health, Incidence, Occupational Health, Air Pollution, Indoor, Risk Assessment, Sick Building Syndrome
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review