CoChat

Predictors and Permanency of Cardiac Conduction Disorders and Necessity of Pacing after Transcatheter Aortic Valve Implantation

BOERLAGE‐VAN DIJK, KIRSTEN, KOOIMAN, KIRSTEN M., YONG, ZE YIE, WIEGERINCK, ESTHER M.A., DAMMAN, PETER, BOUMA, BERTO J., TIJSSEN, JAN G.P., PIEK, JAN J., KNOPS, REINOUD E., BAAN, JAN · 2014 · Pacing and Clinical Electrophysiology
Cited by 83

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background: Transcatheter aortic valve implantation (TAVI) with the Medtronic‐CoreValve bioprosthesis (CoreValve Inc., Irvine, CA, USA) is associated with a high incidence of new‐onset left bundle branch block (LBBB) and cardiac conduction disorders (CCDs) requiring permanent pacemaker (PPM) implantation. Our objective was to investigate the predictors and permanency of CCDs after TAVI and specifically to evaluate the necessity for pacing. Methods: In this single‐center study, we included patients who underwent TAVI with the Medtronic‐CoreValve bioprosthesis. Electrocardiographic evaluation was performed pre‐ and post‐TAVI and at follow‐up. Pacemaker follow‐up data were obtained and analyzed. Results: We included 121 patients (age 81 ± 8 years). LBBB developed in 47 patients, for which prosthesis size (26 mm; odds ratio [OR]: 4.1, 95% confidence interval [CI]: 1.32–12.34, P = 0.01) and prosthesis depth (OR: 1.3, 95% CI: 1.09–1.57, P = 0.004) were independent predictors. In 19%, this new‐onset LBBB was temporary. Requirement for a PPM occurred in 23 patients, for which mitral annular calcification (MAC; OR: 1.3, 95% CI: 1.05–1.56, P = 0.02) and preexisting right bundle branch block (RBBB; OR: 8.5, 95%CI: 1.61–44.91, P = 0.01) were independent predictors. At follow‐up, 52% of the patients were continuously paced, but 22% of the patients had adequate atrioventricular conduction without the necessity for pacing. In the other 26% of the patients there was intermittent pacing. Conclusion: There is a high incidence of new‐onset LBBB and PPM implantation following TAVI with a Medtronic‐CoreValve bioprosthesis. Prosthesis depth and size were predictors for new LBBB, while MAC and preexistent RBBB were predictors for PPM implantation. In approximately one fifth of the patients, new‐onset LBBB and the necessity for pacing are only temporary.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/pace.12460

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Research works printed but not linked: 32

  1. 10.1016/j.jacc.2006.01.049 · DOI · Paper page
  2. 10.1161/CIRCINTERVENTIONS.108.819839 · DOI · Paper page
  3. 10.1016/j.jacc.2007.04.047 · DOI · Paper page
  4. 10.1016/j.jtcvs.2007.07.031 · DOI
  5. 10.1161/CIRCULATIONAHA.107.698258 · DOI · Paper page
  6. 10.1016/j.ahj.2009.12.009 · DOI · Paper page
  7. 10.1016/j.jcin.2010.01.017 · DOI · Paper page
  8. 10.1002/ccd.22457 · DOI
  9. 10.1016/j.ahj.2009.02.016 · DOI · Paper page
  10. 10.1161/CIRCULATIONAHA.109.927152 · DOI · Paper page
  11. 10.1161/CIRCINTERVENTIONS.111.961649 · DOI
  12. 10.1510/icvts.2010.256578 · doi:10.1510/icvts.2010.256578
  13. 10.1111/j.1540-8159.2010.02870.x · doi:10.1111/j.1540-8159.2010.02870.x
  14. 10.1016/j.ahj.2009.05.029 · DOI
  15. Piazza N, 2010, Persistent conduction abnormalities and requirements for pacemaking six months after transcatheter aortic valve implantation, Euro Interv, 6, 475
  16. 10.1016/j.jcin.2008.04.007 · DOI · Paper page
  17. 10.1016/j.jcin.2007.12.009 · DOI · Paper page
  18. 10.1016/j.athoracsur.2009.07.033 · DOI
  19. 10.1002/ccd.21282 · DOI
  20. 10.1161/CIRCULATIONAHA.106.639450 · DOI · Paper page
  21. 10.1016/j.hrthm.2008.04.014 · DOI · Paper page
  22. 10.1016/S0735-1097(85)80335-1 · DOI · Paper page
  23. 10.1016/0002-9149(87)91038-1 · doi:10.1016/0002-9149(87)91038-1
  24. 10.1161/CIRCULATIONAHA.112.001099 · DOI · Paper page
  25. 10.1111/j.1540-8191.2006.00216.x · DOI
  26. Koos R, 2011, Electrocardiographic and imaging predictors for permanent pacemaker requirement after transcatheter aortic valve implantation, J Heart Valve Dis, 20, 83
  27. 10.1016/S0002-9149(97)00671-1 · DOI
  28. 10.1111/j.1540-8159.2009.02170.x · DOI
  29. 10.1016/S0002-9149(00)01448-X · DOI
  30. 10.1093/eurheartj/eht150 · DOI · Paper page
  31. 10.1111/j.1540-8159.1999.tb00534.x · DOI · Paper page
  32. 10.1093/europace/eup361 · DOI · Paper page

Cited by

Metadata

Authors
BOERLAGE‐VAN DIJK, K., KOOIMAN, K. M., YONG, Z. Y., WIEGERINCK, E. M. A., DAMMAN, P., BOUMA, B. J., TIJSSEN, J. G. P., PIEK, J. J., KNOPS, R. E., & BAAN, J.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2014-07-17
Volume
37
Issue
11
Pages
1520-1529
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W1596023507
Cited by
83
References
2
FWCI
4.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.