Background: Transcatheter aortic valve implantation (TAVI) with the Medtronic‐CoreValve bioprosthesis (CoreValve Inc., Irvine, CA, USA) is associated with a high incidence of new‐onset left bundle branch block (LBBB) and cardiac conduction disorders (CCDs) requiring permanent pacemaker (PPM) implantation. Our objective was to investigate the predictors and permanency of CCDs after TAVI and specifically to evaluate the necessity for pacing. Methods: In this single‐center study, we included patients who underwent TAVI with the Medtronic‐CoreValve bioprosthesis. Electrocardiographic evaluation was performed pre‐ and post‐TAVI and at follow‐up. Pacemaker follow‐up data were obtained and analyzed. Results: We included 121 patients (age 81 ± 8 years). LBBB developed in 47 patients, for which prosthesis size (26 mm; odds ratio [OR]: 4.1, 95% confidence interval [CI]: 1.32–12.34, P = 0.01) and prosthesis depth (OR: 1.3, 95% CI: 1.09–1.57, P = 0.004) were independent predictors. In 19%, this new‐onset LBBB was temporary. Requirement for a PPM occurred in 23 patients, for which mitral annular calcification (MAC; OR: 1.3, 95% CI: 1.05–1.56, P = 0.02) and preexisting right bundle branch block (RBBB; OR: 8.5, 95%CI: 1.61–44.91, P = 0.01) were independent predictors. At follow‐up, 52% of the patients were continuously paced, but 22% of the patients had adequate atrioventricular conduction without the necessity for pacing. In the other 26% of the patients there was intermittent pacing. Conclusion: There is a high incidence of new‐onset LBBB and PPM implantation following TAVI with a Medtronic‐CoreValve bioprosthesis. Prosthesis depth and size were predictors for new LBBB, while MAC and preexistent RBBB were predictors for PPM implantation. In approximately one fifth of the patients, new‐onset LBBB and the necessity for pacing are only temporary.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Udo, E. O., Zuithoff, N. P. A., van Hemel, N. M., de Cock, C. C., Hendriks, T., Doevendans, P. A., & Moons, K. G. M. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.014 · Cited by 597
Research works printed but not linked: 32
- 10.1016/j.jacc.2006.01.049 · DOI · Paper page
- 10.1161/CIRCINTERVENTIONS.108.819839 · DOI · Paper page
- 10.1016/j.jacc.2007.04.047 · DOI · Paper page
- 10.1016/j.jtcvs.2007.07.031 · DOI
- 10.1161/CIRCULATIONAHA.107.698258 · DOI · Paper page
- 10.1016/j.ahj.2009.12.009 · DOI · Paper page
- 10.1016/j.jcin.2010.01.017 · DOI · Paper page
- 10.1002/ccd.22457 · DOI
- 10.1016/j.ahj.2009.02.016 · DOI · Paper page
- 10.1161/CIRCULATIONAHA.109.927152 · DOI · Paper page
- 10.1161/CIRCINTERVENTIONS.111.961649 · DOI
- 10.1510/icvts.2010.256578 · doi:10.1510/icvts.2010.256578
- 10.1111/j.1540-8159.2010.02870.x · doi:10.1111/j.1540-8159.2010.02870.x
- 10.1016/j.ahj.2009.05.029 · DOI
- Piazza N, 2010, Persistent conduction abnormalities and requirements for pacemaking six months after transcatheter aortic valve implantation, Euro Interv, 6, 475
- 10.1016/j.jcin.2008.04.007 · DOI · Paper page
- 10.1016/j.jcin.2007.12.009 · DOI · Paper page
- 10.1016/j.athoracsur.2009.07.033 · DOI
- 10.1002/ccd.21282 · DOI
- 10.1161/CIRCULATIONAHA.106.639450 · DOI · Paper page
- 10.1016/j.hrthm.2008.04.014 · DOI · Paper page
- 10.1016/S0735-1097(85)80335-1 · DOI · Paper page
- 10.1016/0002-9149(87)91038-1 · doi:10.1016/0002-9149(87)91038-1
- 10.1161/CIRCULATIONAHA.112.001099 · DOI · Paper page
- 10.1111/j.1540-8191.2006.00216.x · DOI
- Koos R, 2011, Electrocardiographic and imaging predictors for permanent pacemaker requirement after transcatheter aortic valve implantation, J Heart Valve Dis, 20, 83
- 10.1016/S0002-9149(97)00671-1 · DOI
- 10.1111/j.1540-8159.2009.02170.x · DOI
- 10.1016/S0002-9149(00)01448-X · DOI
- 10.1093/eurheartj/eht150 · DOI · Paper page
- 10.1111/j.1540-8159.1999.tb00534.x · DOI · Paper page
- 10.1093/europace/eup361 · DOI · Paper page
Cited by
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab364 · Cited by 2,019
Self-citationKusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.044 · Cited by 1,008
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2022) · EP Europace · doi:10.1093/europace/euab232 · Cited by 914
Self-citationKusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000628 · Cited by 603
Auffret, V., Puri, R., Urena, M., Chamandi, C., Rodriguez-Gabella, T., Philippon, F., & Rodés-Cabau, J. (2017) · Circulation · doi:10.1161/circulationaha.117.028352 · Cited by 550
Metadata
- Authors
- BOERLAGE‐VAN DIJK, K., KOOIMAN, K. M., YONG, Z. Y., WIEGERINCK, E. M. A., DAMMAN, P., BOUMA, B. J., TIJSSEN, J. G. P., PIEK, J. J., KNOPS, R. E., & BAAN, J.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 2014-07-17
- Volume
- 37
- Issue
- 11
- Pages
- 1520-1529
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W1596023507
- Cited by
- 83
- References
- 2
- FWCI
- 4.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.