CoChat

Acute systemic and energy metabolism responses to velocity-based resistance training following an oral glucose load in individuals with excess body weight

Open access
Carrillo‐Arango, Hugo Alejandro, Atencio‐Osorio, Miguel Alejandro, Ordoñez‐Mora, Leidy Tatiana, Benitez‐Gómez, Baisuli, Ramírez‐Vélez, Robinson, Izquierdo, Mikel · 2026 · Experimental Physiology

The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index; 15 of the 42 sources its claims cite were checked for support.

Abstract

We investigated the acute metabolic effects of two velocity‐based resistance training (RT) protocols, differing in intra‐set velocity loss (VL) thresholds, on postprandial substrate oxidation and glycaemic responses following a 75 g oral glucose tolerance test in individuals with excess body weight. A single‐group, randomized, cross‐over design was used, in which each participant completed three experimental conditions in random order: (1) control (rest); (2) RT with 20% velocity loss (VL20); and (3) RT with 40% velocity loss (VL40). Twenty‐four participants (50% female; median body mass index 30.2 kg m −2 , interquartile range 27.9–34.1 kg m −2 ) were included in the final analysis. Each RT session consisted of bilateral leg‐press exercises at 55%–65% of one‐repetition maximum performed in four sets with 3 min rest intervals, while monitoring repetition velocity. Baseline measurements were performed in the fasted state (1012 h) with participants in the supine position for 30 min, after the oral glucose load at 60 min, and during the experimental conditions at 120, 180, and 240 min. Primary outcomes were respiratory quotient, oxygen uptake, carbon dioxide output, resting energy expenditure and substrate oxidation rates. Secondary outcomes included blood glucose, lactate, heart rate, power output and repetition volume. VL40 elicited greater cardiovascular and metabolic stress, evidenced by elevated heart rate and lactate levels ( p < 0.0001). Both RT protocols decreased postprandial respiratory quotient compared with control conditions, with VL40 producing a larger shift towards fat oxidation (time × conditions interaction p < 0.0001). The glucose area under the curve was significantly lower in VL40 than in VL20 or control conditions ( p < 0.0001). These findings suggest that velocity‐based RT acutely improves postprandial metabolism, with higher VL thresholds conferring superior fat oxidation and glycaemic regulation.

Overview

CoChat Summary

TL;DR

In 24 physically inactive adults with excess body weight, a randomized cross-over study found that resistance training done after a 75 g oral glucose load acutely improved postprandial metabolism versus rest. The higher velocity-loss protocol (VL40) produced greater fat oxidation and better glycaemic control than VL20, though the authors caution that the sample was small and relatively healthy.

Key findings

  • 24 participants (50% female; median BMI 30.2 kg m−2, IQR 27.9–34.1) completed three conditions: control, VL20, and VL40 after a 75 g oral glucose tolerance test.
  • Both RT protocols increased respiratory quotient over time, but the AUC for RQ was lower than control in both RT conditions (VL20 p = 0.0263; VL40 p = 0.029), indicating a shift away from carbohydrate reliance.
  • Fat oxidation was greater with VL40 than control: AUC differences were significant for fat oxidation as a percentage (p = 0.029) and also for absolute/relative fat oxidation (p = 0.0023 and p = 0.0147, respectively).
  • Both RT protocols attenuated the glucose response versus control; the paper states the glucose AUC was significantly lower in VL40 than in VL20 or control (p < 0.0001), and VL40 also increased heart rate and lactate more than the other conditions.

Methods

  • Design: Single-group, randomized, cross-over experimental study with three conditions in random order: control (rest), VL20, and VL40; trials separated by ≥7 days.
  • Sample and setting: 24 adults with excess body weight, recruited at the University of Valle in Cali, Colombia; trial conducted from June 2024 to July 2025.
  • Main analysis: Two-way repeated-measures ANOVA tested effects of time and condition; AUCs were compared with one-way ANOVA and Bonferroni post hoc tests; sensitivity analyses were stratified by sex.

Limitations

  • The authors state the sample size was modest and participants were relatively healthy, inactive adults without overt cardiometabolic disease; this limits generalizability to people with established metabolic disorders, cardiovascular disease, or sarcopenic obesity.
  • Dietary intake was not standardized before testing, so habitual macronutrient differences could have affected substrate oxidation.
  • Key mechanistic markers (insulin, incretins, IL-6, TNF-α, antioxidant status) were not measured.
  • The paper also notes bioelectrical impedance was used for body composition instead of more precise imaging, and participants were not formally familiarized with the exercise protocol before testing.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1113/ep093162

Cites

45 of 45 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

FIGURE 1 Overview of experimental protocol. Participants arrived at the laboratory following a 10‐12 h overnight fast and were instructed to avoid unusual physical activity, alcohol and caffeine for 48 h before testing. Upon arrival (time 0 min), medical history, self‐administered questionnaires and anthropometric measurements were obtained. Baseline resting metabolic rate (RMR) and a capillary blood sample were collected before the ingestion of a 75 g oral glucose load. At 60 min post‐glucose ingestion, participants began one of the three experimental conditions. The resistance training sessions (VL20 and VL40) were performed on a leg‐press machine in standardized conditions, with exercise intensity and volume controlled by monitoring velocity loss (VL) during the concentric phase of each repetition using a linear position transducer. In the VL20 conditions, each set was terminated when mean concentric velocity decreased by 20% from the fastest repetition, whereas in VL40 conditions the set continued until a 40% velocity loss was reached, representing a greater degree of fatigue and total workload. The control conditions involved time‐matched rest. Subsequent RMR and blood samples were obtained at 120, 180 and 240 min following the start of each of the conditions. All experimental procedures were performed at the same time of day to account for diurnal variation in metabolic and hormonal responses. This cross‐over design enabled each participant to serve as their own control, thereby reducing interindividual variability and improving the sensitivity for detecting differences in metabolic and physiological responses to varying levels of resistance exercise‐induced fatigue. Face‐mask icons represent indirect calorimetry (metabolic cart) assessments. The soda cup icon represents a 75 g oral glucose dose. Postprandial plasma glucose (PPG). Drop icons represent capillary blood sample assessment.
FIGURE 1 Overview of experimental protocol. Participants arrived at the laboratory following a 10‐12 h overnight fast and were instructed to avoid unusual physical activity, alcohol and caffeine for 48 h before testing. Upon arrival (time 0 min), medical history, self‐administered questionnaires and anthropometric measurements were obtained. Baseline resting metabolic rate (RMR) and a capillary blood sample were collected before the ingestion of a 75 g oral glucose load. At 60 min post‐glucose ingestion, participants began one of the three experimental conditions. The resistance training sessions (VL20 and VL40) were performed on a leg‐press machine in standardized conditions, with exercise intensity and volume controlled by monitoring velocity loss (VL) during the concentric phase of each repetition using a linear position transducer. In the VL20 conditions, each set was terminated when mean concentric velocity decreased by 20% from the fastest repetition, whereas in VL40 conditions the set continued until a 40% velocity loss was reached, representing a greater degree of fatigue and total workload. The control conditions involved time‐matched rest. Subsequent RMR and blood samples were obtained at 120, 180 and 240 min following the start of each of the conditions. All experimental procedures were performed at the same time of day to account for diurnal variation in metabolic and hormonal responses. This cross‐over design enabled each participant to serve as their own control, thereby reducing interindividual variability and improving the sensitivity for detecting differences in metabolic and physiological responses to varying levels of resistance exercise‐induced fatigue. Face‐mask icons represent indirect calorimetry (metabolic cart) assessments. The soda cup icon represents a 75 g oral glucose dose. Postprandial plasma glucose (PPG). Drop icons represent capillary blood sample assessment.CC BY · PubMed Central
FIGURE 2 Training performance and acute physiological responses during the velocity‐based resistance training protocols. (a) Number of repetitions performed per set. (b) Absolute mean propulsive velocity (ΔMPV; in metres per second) per set. (c) Relative change in mean propulsive velocity (ΔMPV; as a percentage). (d) Heart rate responses (in beats per minute) recorded 1 and 3 min after each set. (e) Blood lactate concentration (in millimoles per litre) measured 1 and 3 min after each set. (f) Individual values of repetition maximum (RM) and peak power (PP) during leg‐press exercise. Data are presented as the mean (SD).
FIGURE 2 Training performance and acute physiological responses during the velocity‐based resistance training protocols. (a) Number of repetitions performed per set. (b) Absolute mean propulsive velocity (ΔMPV; in metres per second) per set. (c) Relative change in mean propulsive velocity (ΔMPV; as a percentage). (d) Heart rate responses (in beats per minute) recorded 1 and 3 min after each set. (e) Blood lactate concentration (in millimoles per litre) measured 1 and 3 min after each set. (f) Individual values of repetition maximum (RM) and peak power (PP) during leg‐press exercise. Data are presented as the mean (SD).CC BY · PubMed Central
FIGURE 3 Energy metabolism responses following oral glucose ingestion in different experimental conditions (control, VL20 and VL40). Time course of changes in: (a, b) respiratory quotient (RQ); (c, d) resting energy expenditure (REE) kcal/day; (e, f) resting energy expenditure (REE) kcal/min; (g, h) total energy oxidation (TEO); (i, j) oxygen uptake (VO2); and (k,l) carbon dioxide output (VCO2) across the three experimental conditions: control (rest), low‐velocity loss RT (VL20) and high‐velocity loss RT (VL40); (b,d,f,h,j,l) area under the curve (AUC) for energy metabolism responses. Control ( n = 24); VL20 ( Velocity loss 20%, n = 24); VL40 ( Velocity loss 40%, n = 24) conditions. All values are reported as the mean (SD). For AUC, each data point represents one participant (n = 24, ♀ grey circles, n = 12; ♂ white circles, n = 12). Bars denote the mean (SD).
FIGURE 3 Energy metabolism responses following oral glucose ingestion in different experimental conditions (control, VL20 and VL40). Time course of changes in: (a, b) respiratory quotient (RQ); (c, d) resting energy expenditure (REE) kcal/day; (e, f) resting energy expenditure (REE) kcal/min; (g, h) total energy oxidation (TEO); (i, j) oxygen uptake (VO2); and (k,l) carbon dioxide output (VCO2) across the three experimental conditions: control (rest), low‐velocity loss RT (VL20) and high‐velocity loss RT (VL40); (b,d,f,h,j,l) area under the curve (AUC) for energy metabolism responses. Control ( n = 24); VL20 ( Velocity loss 20%, n = 24); VL40 ( Velocity loss 40%, n = 24) conditions. All values are reported as the mean (SD). For AUC, each data point represents one participant (n = 24, ♀ grey circles, n = 12; ♂ white circles, n = 12). Bars denote the mean (SD).CC BY · PubMed Central
FIGURE 4 Substrate oxidation responses following oral glucose ingestion in different experimental conditions (control, VL20 and VL40). Time course of changes in: (a, c) percentage contribution of fat and carbohydrate oxidation over time; (e, g) absolute fat and carbohydrate oxidation rates (in milligrams per kilogram per minute); (i, k) fat and carbohydrate oxidation rates normalized to muscle mass (in milligrams per kilogram per minute); (b,d,f,h,j,l) area under the curve (AUC) for total and muscle mass‐adjusted fat and carbohydrate oxidation. Control ( n = 24); VL20 ( velocity loss 20%, n = 24); VL40 ( velocity loss 40%, n = 24) conditions. All values are reported as the mean (SD). For AUC, each data point represents one participant (n = 24, ♀ grey circles, n = 12; ♂ white circles, n = 12). Bars denote the mean (SD).
FIGURE 4 Substrate oxidation responses following oral glucose ingestion in different experimental conditions (control, VL20 and VL40). Time course of changes in: (a, c) percentage contribution of fat and carbohydrate oxidation over time; (e, g) absolute fat and carbohydrate oxidation rates (in milligrams per kilogram per minute); (i, k) fat and carbohydrate oxidation rates normalized to muscle mass (in milligrams per kilogram per minute); (b,d,f,h,j,l) area under the curve (AUC) for total and muscle mass‐adjusted fat and carbohydrate oxidation. Control ( n = 24); VL20 ( velocity loss 20%, n = 24); VL40 ( velocity loss 40%, n = 24) conditions. All values are reported as the mean (SD). For AUC, each data point represents one participant (n = 24, ♀ grey circles, n = 12; ♂ white circles, n = 12). Bars denote the mean (SD).CC BY · PubMed Central
FIGURE 5 Cardiometabolic and haemodynamic responses following oral glucose ingestion in different experimental conditions (control, VL20 and VL40). Time course of changes in glucose (a), lactate (c), systolic (e), diastolic (g) and mean arterial pressure (i) and heart rate (k) following a 75 g oral glucose load in control, VL20 and VL40 conditions. Corresponding AUC comparisons (b, d, f, h, j, l) are presented next to each time course panel. Heart rate (HR; Polar H10 HR monitor, Polar Electro Oy, Kempele, Finland) and blood pressure (Omron Healthcare Co., Ltd, Kyoto, Japan) were recorded at the end of every stage (i.e. last 15 s of each stage). Control ( n = 24); VL20 ( velocity loss 20%, n = 24); VL40 ( velocity loss 40%, n = 24) conditions. All values are reported as the mean (SD). For the AUC, each data point represents one participant (n = 24, ♀ grey circle, n = 12; ♂ white circle, n = 12). Bars denote the mean (SD).
FIGURE 5 Cardiometabolic and haemodynamic responses following oral glucose ingestion in different experimental conditions (control, VL20 and VL40). Time course of changes in glucose (a), lactate (c), systolic (e), diastolic (g) and mean arterial pressure (i) and heart rate (k) following a 75 g oral glucose load in control, VL20 and VL40 conditions. Corresponding AUC comparisons (b, d, f, h, j, l) are presented next to each time course panel. Heart rate (HR; Polar H10 HR monitor, Polar Electro Oy, Kempele, Finland) and blood pressure (Omron Healthcare Co., Ltd, Kyoto, Japan) were recorded at the end of every stage (i.e. last 15 s of each stage). Control ( n = 24); VL20 ( velocity loss 20%, n = 24); VL40 ( velocity loss 40%, n = 24) conditions. All values are reported as the mean (SD). For the AUC, each data point represents one participant (n = 24, ♀ grey circle, n = 12; ♂ white circle, n = 12). Bars denote the mean (SD).CC BY · PubMed Central

Verification

Claims the paper makes

12 Valid · 2 Not valid · 14 Not checked · 90 Own results and interpretations

40 more claims

Create a free account to see all 118 claims and every source verdict.

See all claims — free account
  • It may state two separate claims as one. 50
  • Probably not a substantial claim. 35

Create a free account to see these claims.

Citations

Cites

Research works printed but not linked: 1

  1. Ramírez‐Vélez R., 2012, The Fantastic instrument's validity and reliability for measuring Colombian adults’ life‐style, Revista de salud publica (Bogota, Colombia), 14, 226

Cited by

See all 1

Metadata

Authors
Carrillo‐Arango, H. A., Atencio‐Osorio, M. A., Ordoñez‐Mora, L. T., Benitez‐Gómez, B., Ramírez‐Vélez, R., & Izquierdo, M.
Affiliations
  • Grupo de Investigación en Deporte de Rendimiento (GRINDER), Programa de Educación Física y Deporte Universidad del Valle Cali Colombia
  • Universidad del Valle (CO)
  • Universidad Santiago de Cali (CO)
  • Universidad Pública de Navarra (UPNA) (ES)
  • Navarrabiomed, Hospital Universitario de Navarra (HUN), Universidad Pública de Navarra (UPNA) Instituto de Investigación Sanitaria de Navarra (IdiSNA) Pamplona Spain
Corresponding author
Ramírez‐Vélez, Robinson
Venue
Experimental Physiology
Publisher
Wiley
Published
2025-12-11
Volume
111
Issue
4
Pages
1847-1860
ISSN
  • 0958-0670 (ISSN-L)
  • 1469-445X
OpenAlex
W4417247790
Cited by
1
References
40
Citations by year
2026: 1
FWCI
1.22
Type
journal article
Language
en
Open access
Licence
Locations
  • Experimental Physiology (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • PubMed Central (publishedVersion, cc-by)
  • Academica-e (Universidad Pública de Navarra) (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
Universidad del Valle (CTO 0776‐2023‐UNIVALLE‐Conv‐150,151,152)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
  • Health Sciences › Nursing › Nutrition and Dietetics › Muscle metabolism and nutrition
Keywords
fat oxidation, glycemic response, oral glucose tolerance test, overweight, energy expenditure, respiratory quotient, cardiovascular stress, lactate, leg press, acute metabolic response
MeSH terms
Adult, Blood Glucose, Energy Metabolism, Female, Glucose, Glucose Tolerance Test, Humans, Male, Oxygen Consumption, Cross-Over Studies, Postprandial Period, Overweight, Resistance Training, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-09, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-09 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.