Abstract
1. Cat hind limb peripheral nerves were fitted with cuff recording electrodes, and their distal portions were later cut and ligated to prevent regeneration. The compound action potential amplitude initially declined with a time constant between 1 and 2 months and then remained relatively unchanged for periods of more than a year. Similar but smaller changes were observed in the conduction velocity of the nerves which also stabilized after a few months. 2. In nerves that were cut and resutured to their distal stumps or sutured directly to nearby muscles, a recovery was observed. The time course was well fitted by an initial exponential decay with a similar time constant to that above, followed by an exponential recovery with a longer time constant (3‐4 months). Nerve conduction, muscle potentials and twitch tension often recovered to control values, even when the amplitude of the nerve compound action potential remained depressed. 3. Thus, nerve fibres survive axotomy for long periods of time and continue to conduct action potentials, even if unable to regenerate to appropriate end‐organs. When regeneration is permitted, a fraction of nerve fibres may reinnervate nearly all end‐organs. The diameter and conduction velocity of these nerve fibres presumably increase toward control values, while other fibres remain subnormal in these parameters. 4. Factors in the design of cuff electrodes which determine the amplitude of compound action potentials are described in an Appendix.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stable long-term recordings from cat peripheral nerves
Stein, R. B., Nichols, T. R., Jhamandas, J., Davis, L., & Charles, D. (1977) · Brain Research · doi:10.1016/0006-8993(77)90233-5 · Cited by 160
Self-citation
Cited by
A spiral nerve cuff electrode for peripheral nerve stimulation
Naples, G. G., Mortimer, J. T., Scheiner, A., & Sweeney, J. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8670 · Cited by 415
Peripheral Nerve Regeneration and Muscle Reinnervation
Gordon, T. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21228652 · Cited by 397
Self-citationSelective Stimulation of Cat Sciatic Nerve Using an Array of Varying-Length Microelectrodes
Branner, A., Stein, R. B., & Normann, R. A. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.85.4.1585 · Cited by 359
Self-citationDhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354
Axotomy-induced alterations in the electrophysiological characteristics of neurons
Titmus, M. (1990) · Progress in Neurobiology · doi:10.1016/0301-0082(90)90039-j · Cited by 275
Outcome measures of peripheral nerve regeneration
Wood, M. D., Kemp, S. W. P., Weber, C., Borschel, G. H., & Gordon, T. (2011) · Annals of Anatomy - Anatomischer Anzeiger · doi:10.1016/j.aanat.2011.04.008 · Cited by 264
Self-citationA multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats
Branner, A., & Normann, R. A. (2000) · Brain Research Bulletin · doi:10.1016/s0361-9230(99)00231-2 · Cited by 234
Agnew, W. F., McCreery, D. B., Yuen, T. G. H., & Bullara, L. A. (1989) · Annals of Biomedical Engineering · doi:10.1007/bf02364272 · Cited by 185
Cutaneous whole nerve recordings used for correction of footdrop in hemiplegic man
Haugland, M. K., & Sinkjaer, T. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.481970 · Cited by 168
Ortiz-Catalan, M., Brånemark, R., Håkansson, B., & Delbeke, J. (2012) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-11-33 · Cited by 144
“However, the axons that used to innervate those muscles remain indefinitely viable on the nerves close to the stump [110].”
BackgroundTargeted Muscle Reinnervation for the Upper and Lower Extremity
Kuiken, T. A., Barlow, A. K., Hargrove, L. J., & Dumanian, G. A. (2017) · Techniques in Orthopaedics · doi:10.1097/bto.0000000000000194 · Cited by 143
Adaptive self-healing electronic epineurium for chronic bidirectional neural interfaces
Song, K.-I., Seo, H., Seong, D., Kim, S., Yu, K. J., Kim, Y.-C., Kim, J., Kwon, S. J., Han, H.-S., Youn, I., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18025-3 · Cited by 120
“The recording of sensory compound action potentials (CAPs) was also achieved by the spiral cuffs and utilized to demonstrate foot drop correction 13,14 .”
Cuff electrodes for long-term recording of natural sensory information
Struijk, J. J., Thomsen, M., Larsen, J. O., & Sinkjaer, T. (1999) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.765194 · Cited by 97
Long‐term effects of axotomy on neural activity during cat locomotion.
Gordon, T., Hoffer, J. A., Jhamandas, J., & Stein, R. B. (1980) · The Journal of Physiology · doi:10.1113/jphysiol.1980.sp013283 · Cited by 65
Self-citationHow to Use Nerve Cuffs to Stimulate, Record or Modulate Neural Activity
Hoffer, J.-A., & Kallesøe, K. (2000) · Frontiers in Neuroscience · doi:10.1201/9781420039054.ch5 · Cited by 21
Self-citationMurphy, B., Krieger, C., & Hoffer, J.-A. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.08.013 · Cited by 13
Self-citation(2001) · PubMed · Cited by 12
Metadata
- Authors
- Davis, L. A., Gordon, T., Hoffer, J. A., Jhamandas, J., & Stein, R. B.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1978-12
- Volume
- 285
- Issue
- 1
- Pages
- 543-559
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W1996847991
- Cited by
- 103
- References
- 1
- FWCI
- 1.43
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.