CoChat

Human phase response curve to intermittent blue light using a commercially available device

Open access
Revell, Victoria L., Molina, Thomas A., Eastman, Charmane I. · 2012 · The Journal of Physiology
Cited by 73

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

Key points: Misalignment between the internal circadian clock driving daily rhythms in physiology and behaviour, such as sleepiness, performance and metabolism, and the sleep–wake schedule, as occurs in jet lag and night shift work, can have profound, harmful consequences for health, performance and safety. Light applied at specific times of day can be used to shift the timing of the clock and reduce this circadian misalignment. We show for the first time that a small, commercially available, portable blue light device is capable of shifting the clock when it is administered daily over a 2 h window (90 min blue light as 30 min pulses with 15 min breaks). The direction and amount that the clock is shifted depends on the time of day that the light is administered. The results of this work provide a practical, effective light treatment that can be used in the real world. Abstract Light shifts the timing of the circadian clock according to a phase response curve (PRC). To date, all human light PRCs have been to long durations of bright white light. However, melanopsin, the primary photopigment for the circadian system, is most sensitive to short wavelength blue light. Therefore, to optimise light treatment it is important to generate a blue light PRC. We used a small, commercially available blue LED light box, screen size 11.2 × 6.6 cm at ∼50 cm, ∼200 μW cm−2, ∼185 lux. Subjects participated in two 5 day laboratory sessions 1 week apart. Each session consisted of circadian phase assessments to obtain melatonin profiles before and after 3 days of free‐running through an ultradian light–dark cycle (2.5 h wake in dim light, 1.5 h sleep in the dark), forced desynchrony protocol. During one session subjects received intermittent blue light (three 30 min pulses over 2 h) once a day for the 3 days of free‐running, and in the other session (control) they remained in dim room light, counterbalanced. The time of blue light was varied among subjects to cover the entire 24 h day. For each individual, the phase shift to blue light was corrected for the free‐run determined during the control session. The blue light PRC had a broad advance region starting in the morning and extending through the afternoon. The delay region started a few hours before bedtime and extended through the night. This is the first PRC to be constructed to blue light and to a stimulus that could be used in the real world.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.2012.235416

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 73

Metadata

Authors
Revell, V. L., Molina, T. A., & Eastman, C. I.
Venue
The Journal of Physiology
Publisher
Wiley
Published
2012-07-23
Volume
590
Issue
19
Pages
4859-4868
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2127138742
Cited by
73
References
17
FWCI
2.34
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.