Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Subfascicle Stimulation Selectivity with the Flat Interface Nerve Electrode

Leventhal, Daniel K., Durand, Dominique M. · 2003 · Annals of Biomedical Engineering

Abstract

The flat interface nerve electrode (FINE) is an alternative to cylindrical nerve cuffs for functional electrical stimulation (FES). By elongating the nerve in cross section, the FINE places more stimulating contacts around the nerve, and moves central axons closer to the electrode surface. Previous experiments have demonstrated that the FINE can activate selectively each fascicle in the cat sciatic nerve, and modeling studies have indicated that it should be possible to selectively activate groups of axons within individual fascicles. This hypothesis is tested using a combination of experimental and modeling techniques. Pairs of contacts stimulating the same fascicle were tested for subfascicle level selectivity, defined as the fraction of fibers activated by one contact but not by the other. It was possible to achieve greater than 90% selectivity with the FINE, but there was considerable variation in the results. The modeling studies showed that the selectivity achievable with a given contact pair depended strongly on the relative locations of the electrode and fascicle. Therefore, reshaping the cross section of a nerve can provide selectivity at the subfascicular level, but the electrode design must be optimized to improve selectivity across different nerve geometries.

Overview

Integrity signals

Registry

Crossref · 10.1114/1.1569266

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 22 references

Cited by

See all 87

Metadata

Authors
Leventhal, D. K., & Durand, D. M.
Affiliations
Case Western Reserve University (US)
Venue
Annals of Biomedical Engineering
Published
2003-06
Volume
31
Issue
6
Pages
643-652
ISSN
0090-6964 (ISSN-L)
OpenAlex
W2078887776
Cited by
81
References
22
Citations by year
2025: 1 · 2024: 2 · 2023: 1 · 2022: 1 · 2021: 7 · 2020: 4 · 2019: 8 · 2018: 2 · 2017: 2 · 2015: 4 · 2014: 2 · 2013: 6 · 2012: 3
FWCI
1.28
Type
journal article
Language
en
Open access
closed
Locations
  • Annals of Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institutes of Health
  • National Institute of Neurological Disorders and Stroke (2R01 NS32845, R01NS032845)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
  • Health Sciences › Medicine › Anesthesiology and Pain Medicine › Pain Management and Treatment
Keywords
functional electrical stimulation, sciatic nerve, cuff electrodes
MeSH terms
Animals, Cats, Computer Simulation, Electric Stimulation, Electrodes, Implanted, Models, Neurological, Nerve Fibers, Sciatic Nerve, Sensitivity and Specificity, Reproducibility of Results, Equipment Failure Analysis, Finite Element Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Subfascicle Stimulation Selectivity with the Flat Interface Nerve Electrode. https://app.cochat.ai/papers/10.1114/1.1569266
The paper
Leventhal, D. K., & Durand, D. M. (2003). Subfascicle Stimulation Selectivity with the Flat Interface Nerve Electrode. Annals of Biomedical Engineering. https://doi.org/10.1114/1.1569266

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.