The DOI matches its Crossref record.
Candidates for the Mechanosensory System in Bone
Abstract
Some potential mechanisms by which bone cells sense mechanical loads are described and hypotheses concerning the functioning of these mechanisms are explored. It is well known that bone tissue adapts its structure to its mechanical load environment. Recent research has illuminated the biological response of bone to mechanical loading at the cellular level, but the precise mechanosensory system that signals bone cells to deposit or resorb tissue has not been identifed. The purpose of this paper is to describe the current status of this research and to suggest some possible mechanosensory systems by which bone cells might sense environmental loads.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mechanical Stimulation of Bone in Vivo Reduces Osteocyte Expression of Sost/Sclerostin
Robling, A. G., Niziolek, P. J., Baldridge, L. A., Condon, K. W., Allen, M. R., Alam, I., Mantila, S. M., Gluhak-Heinrich, J., Bellido, T. M., Harris, S. E., et al. (2008) · Journal of Biological Chemistry · doi:10.1074/jbc.m705092200 · Cited by 1,350
Effects of mechanical forces on maintenance and adaptation of form in trabecular bone
Huiskes, R., Ruimerman, R., van Lenthe, G. H., & Janssen, J. D. (2000) · Nature · doi:10.1038/35015116 · Cited by 1,180
Mechanotransduction in bone—role of the lacunocanalicular network
Burger, E. H., & Klein‐Nulend, J. (1999) · The FASEB Journal · doi:10.1096/fasebj.13.9001.s101 · Cited by 897
Li, X., Ominsky, M. S., Warmington, K. S., Morony, S., Gong, J., Cao, J., Gao, Y., Shalhoub, V., Tipton, B., Haldankar, R., et al. (2009) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.081206 · Cited by 784
Sensitivity of osteocytes to biomechanical stress in vitro
Klein‐Nulend, J., Van Der Plas, A., Semeins, C. M., Ajubi, N. E., Erangos, J. A., Nijweide, P. J., & Burger, E. H. (1995) · The FASEB Journal · doi:10.1096/fasebj.9.5.7896017 · Cited by 783
The aging of Wolff’s “law”: Ontogeny and responses to mechanical loading in cortical bone
Pearson, O. M., & Lieberman, D. E. (2004) · American Journal of Physical Anthropology · doi:10.1002/ajpa.20155 · Cited by 745
Cartilage Tissue Remodeling in Response to Mechanical Forces
Grodzinsky, A. J., Levenston, M. E., Jin, M., & Frank, E. H. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.691 · Cited by 642
An overview of the regulation of bone remodelling at the cellular level
Kular, J., Tickner, J., Chim, S. M., & Xu, J. (2012) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2012.03.021 · Cited by 534
Mechanosensation and transduction in osteocytes
Klein-Nulend, J., Bakker, A. D., Bacabac, R. G., Vatsa, A., & Weinbaum, S. (2013) · Bone · doi:10.1016/j.bone.2012.10.013 · Cited by 528
Modelling bone tissue fracture and healing: a review
Doblaré, M., Garcı́a, J. M., & Gómez, M. J. (2004) · Engineering Fracture Mechanics · doi:10.1016/j.engfracmech.2003.08.003 · Cited by 504
Department of Mechanical and Biomedical Engineering, N. U. O. I. G., Birmingham, E., Niebur, G., McHugh, P., Shaw, G., Barry, F., & McNamara, L. (2012) · European Cells and Materials · doi:10.22203/ecm.v023a02 · Cited by 490
Bone physiology as inspiration for tissue regenerative therapies
Lopes, D., Martins-Cruz, C., Oliveira, M. B., & Mano, J. F. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.09.028 · Cited by 421
You, L., Cowin, S. C., Schaffler, M. B., & Weinbaum, S. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00107-5 · Cited by 418
Self-citationFunction of osteocytes in bone
Aarden, E. M., Nijweide, P. J., & Burger, E. H. (1994) · Journal of Cellular Biochemistry · doi:10.1002/jcb.240550304 · Cited by 409
Proposal for the regulatory mechanism of Wolff's law
Mullender, M. G., & Huiskes, R. (1995) · Journal of Orthopaedic Research · doi:10.1002/jor.1100130405 · Cited by 408
Fritton, S. P., J. McLeod, K., & Rubin, C. T. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00210-9 · Cited by 401
Biodegradable polymer scaffolds to regenerate organs
Thomson, R. C., Wake, M. C., Yaszemski, M. J., & Mikos, A. G. (1995) · Advances in Polymer Science · doi:10.1007/3540587888_18 · Cited by 383
Fluid and Solute Transport in Bone: Flow-Induced Mechanotransduction
Fritton, S. P., & Weinbaum, S. (2009) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.010908.165136 · Cited by 380
Osteocytes as mechanosensors in the inhibition of bone resorption due to mechanical loading
You, L., Temiyasathit, S., Lee, P., Kim, C. H., Tummala, P., Yao, W., Kingery, W., Malone, A. M., Kwon, R. Y., & Jacobs, C. R. (2008) · Bone · doi:10.1016/j.bone.2007.09.047 · Cited by 359
Genetos, D. C., Kephart, C. J., Zhang, Y., Yellowley, C. E., & Donahue, H. J. (2007) · Journal of Cellular Physiology · doi:10.1002/jcp.21021 · Cited by 328
Nitric Oxide Synthase Expression in Bone Cells
Fox, S. W., & Chow, J. W. M. (1998) · Bone · doi:10.1016/s8756-3282(98)00070-2 · Cited by 320
“Whither flows the fluid in bone?” An osteocyte's perspective
Knothe Tate, M. L. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00123-4 · Cited by 309
A theoretical framework for strain-related trabecular bone maintenance and adaptation
Ruimerman, R., Hilbers, P., van Rietbergen, B., & Huiskes, R. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.03.037 · Cited by 300
If bone is the answer, then what is the question?
HUISKES, R. (2000) · Journal of Anatomy · doi:10.1046/j.1469-7580.2000.19720145.x · Cited by 296
Mullender, M. G., Huiskes, R., & Weinans, H. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90049-3 · Cited by 284
Mechanosensation and transduction in osteocytes
Bonewald, L. F. (2006) · BoneKEy-Osteovision · doi:10.1138/20060233 · Cited by 283
Osteoporosis after spinal cord injury.
Jiang, S.-D., Dai, L.-Y., & Jiang, L.-S. (2006) · Osteoporosis International · doi:10.1007/s00198-005-2028-8 · Cited by 282
Single Cell Mechanotransduction and Its Modulation Analyzed by Atomic Force Microscope Indentation
Charras, G. T., & Horton, M. A. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75638-5 · Cited by 281
Review: Bone tissue engineering: The role of interstitial fluid flow
Hillsley, M. V., & Frangos, J. A. (1994) · Biotechnology and Bioengineering · doi:10.1002/bit.260430706 · Cited by 270
A model for the role of integrins in flow induced mechanotransduction in osteocytes
Wang, Y., McNamara, L. M., Schaffler, M. B., & Weinbaum, S. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0707246104 · Cited by 265
Osteocyte density changes in aging and osteoporosis
Mullender, M. G., van der Meer, D. D., Huiskes, R., & Lips, P. (1996) · Bone · doi:10.1016/8756-3282(95)00444-0 · Cited by 265
“Lc/BV - 2R + t - 2k ' (3) where k and t are the same factors as above.”
Relevance of collagen piezoelectricity to “Wolff's Law”: A critical review
Ahn, A. C., & Grodzinsky, A. J. (2009) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2009.02.006 · Cited by 257
Lean, J. M., Mackay, A. G., Chow, J. W., & Chambers, T. J. (1996) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1996.270.6.e937 · Cited by 139
Metadata
- Authors
- Cowin, S. C., Moss-Salentijn, L., & Moss, M. L.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 1991-05-01
- Volume
- 113
- Issue
- 2
- Pages
- 191-197
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2083049128
- Cited by
- 468
- References
- 0
- FWCI
- 2.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.