The DOI matches its Crossref record.
Properties and an Anisotropic Model of Cancellous Bone From the Proximal Tibial Epiphysis
Abstract
An investigation has been made of the source and magnitude of anisotropic material properties of cancellous bone in the proximal epiphysis of the human tibia. Results are reported for stiffness measurements made in three orthogonal directions on 21 cubes of cancellous bone before testing to failure along one of the three principal axes. The structure is approximately transversely isotropic. Strength and stiffness are linear with area fraction for loading along the isotropic axis. Strength is proportional to stiffness for all directions. A finite element model is proposed, based on experimental observations, which enables one to predict the elastic constants of cylindrically structured cancellous bone in the tibia from morphological measurements in the transverse plane.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mechanical properties and the hierarchical structure of bone
Rho, J.-Y., Kuhn-Spearing, L., & Zioupos, P. (1998) · Medical Engineering & Physics · doi:10.1016/s1350-4533(98)00007-1 · Cited by 2,588
Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
Rho, J. Y., Ashman, R. B., & Turner, C. H. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90042-d · Cited by 1,283
Auxetic metamaterials and structures: a review
Ren, X., Das, R., Tran, P., Ngo, T. D., & Xie, Y. M. (2018) · Smart Materials and Structures · doi:10.1088/1361-665x/aaa61c · Cited by 1,277
The mechanical behaviour of cancellous bone
Gibson, L. J. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90287-8 · Cited by 932
van Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865
“Williams and Lewis (1982) used a two-dimensional FE model of a trabecular cross-section in combination with experimental results.”
Auxetic mechanical metamaterials
Kolken, H. M. A., & Zadpoor, A. A. (2017) · RSC Advances · doi:10.1039/c6ra27333e · Cited by 788
Three-dimensional methods for quantification of cancellous bone architecture
Odgaard, A. (1997) · Bone · doi:10.1016/s8756-3282(97)00007-0 · Cited by 777
The relationship between the structural and orthogonal compressive properties of trabecular bone
Goulet, R. W., Goldstein, S. A., Ciarelli, M. J., Kuhn, J. L., Brown, M. B., & Feldkamp, L. A. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90014-0 · Cited by 741
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
The mechanical properties of trabecular bone: Dependence on anatomic location and function
Goldstein, S. A. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90023-6 · Cited by 687
Predicting the compressive mechanical behavior of bone
Keller, T. S. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90056-6 · Cited by 667
Müller, R., Van Campenhout, H., Van Damme, B., Van der Perre, G., Dequeker, J., Hildebrand, T., & Rüegsegger, P. (1998) · Bone · doi:10.1016/s8756-3282(98)00068-4 · Cited by 656
The behavior of adaptive bone-remodeling simulation models
Weinans, H., Huiskes, R., & Grootenboer, H. J. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90056-7 · Cited by 628
Turner, C. H., Rho, J., Takano, Y., Tsui, T. Y., & Pharr, G. M. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00177-8 · Cited by 547
A survey of finite element analysis in orthopedic biomechanics: The first decade
Huiskes, R., & Chao, E. Y. S. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90072-6 · Cited by 539
Tailoring materials with prescribed elastic properties
Sigmund, O. (1995) · Mechanics of Materials · doi:10.1016/0167-6636(94)00069-7 · Cited by 538
Choi, K., Kuhn, J. L., Ciarelli, M. J., & Goldstein, S. A. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90003-l · Cited by 532
Mosekilde, L., Mosekilde, L., & Danielsen, C. C. (1987) · Bone · doi:10.1016/8756-3282(87)90074-3 · Cited by 492
Negative Poisson's Ratio in Modern Functional Materials
Huang, C., & Chen, L. (2016) · Advanced Materials · doi:10.1002/adma.201601363 · Cited by 439
Ciarelli, M. J., Goldstein, S. A., Kuhn, J. L., Cody, D. D., & Brown, M. B. (1991) · Journal of Orthopaedic Research · doi:10.1002/jor.1100090507 · Cited by 401
Elastic modulus of trabecular bone material
Ashman, R. B., & Rho, J. Y. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90167-4 · Cited by 392
Architecture and properties of anisotropic polymer composite scaffolds for bone tissue engineering
Mathieu, L. M., Mueller, T. L., Bourban, P.-E., Pioletti, D. P., Müller, R., & Månson, J.-A. E. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.07.015 · Cited by 349
The fabric dependence of the orthotropic elastic constants of cancellous bone
Turner, C. H., Cowin, S. C., Rho, J. Y., Ashman, R. B., & Rice, J. C. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90048-8 · Cited by 346
Hollister, S. J., Brennan, J. M., & Kikuchi, N. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90019-1 · Cited by 322
A 20-Year Perspective on the Mechanical Properties of Trabecular Bone
Keaveny, T. M., & Hayes, W. C. (1993) · Journal of Biomechanical Engineering · doi:10.1115/1.2895536 · Cited by 318
Mosekilde, L. (1989) · Bone · doi:10.1016/8756-3282(89)90074-4 · Cited by 316
Age-related changes in vertebral trabecular bone architecture—assessed by a new method
Mosekilde, L. (1988) · Bone · doi:10.1016/8756-3282(88)90038-5 · Cited by 314
The mechanical properties of human tibial trabecular bone as a function of metaphyseal location
Goldstein, S. A., Wilson, D. L., Sonstegard, D. A., & Matthews, L. S. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90097-0 · Cited by 292
Manufacturing, characteristics and applications of auxetic foams: A state-of-the-art review
Jiang, W., Ren, X., Wang, S. L., Zhang, X. G., Zhang, X. Y., Luo, C., Xie, Y. M., Scarpa, F., Alderson, A., & Evans, K. E. (2022) · Composites Part B: Engineering · doi:10.1016/j.compositesb.2022.109733 · Cited by 284
An Application of Nanoindentation Technique to Measure Bone Tissue Lamellae Properties
Hoffler, C. E., Guo, X. E., Zysset, P. K., & Goldstein, S. A. (2005) · Journal of Biomechanical Engineering · doi:10.1115/1.2073671 · Cited by 222
Mechanical properties of trabecular bone. Dependency on strain rate
Linde, F., Nørgaard, P., Hvid, I., Odgaard, A., & Søballe, K. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90305-7 · Cited by 171
Pangon, A., Saesoo, S., Saengkrit, N., Ruktanonchai, U., & Intasanta, V. (2016) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2016.02.053 · Cited by 112
Dependence of elastic constants of an anisotropic porous material upon porosity and fabric
Turner, C. H., & Cowin, S. C. (1987) · Journal of Materials Science · doi:10.1007/bf01161180 · Cited by 60
Local strain and damage mapping in single trabeculae during three-point bending tests
Jungmann, R., Szabo, M. E., Schitter, G., Yue-Sing Tang, R., Vashishth, D., Hansma, P. K., & Thurner, P. J. (2011) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2010.12.009 · Cited by 57
Wang, H., Zuo, Y., Zou, Q., Cheng, L., Huang, D., Wang, L., & Li, Y. (2009) · Journal of Polymer Science Part A: Polymer Chemistry · doi:10.1002/pola.23171 · Cited by 48
(1997) · Cellular Solids · doi:10.1017/cbo9781139878326.013 · Cited by 16
Metadata
- Authors
- Williams, J. L., & Lewis, J. L.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 1982-02-01
- Volume
- 104
- Issue
- 1
- Pages
- 50-56
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2165718065
- Cited by
- 415
- References
- 0
- FWCI
- 15.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.