Fully integrated, standalone zero field optically pumped magnetometer for biomagnetism
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
We describe the operation and results of our first generation zero field optically pumped magnetometer (OPM) developed for biomedical applications. The OPM technology is one of the most promising non-cryogenic candidates to replace superconducting quantum interference device (SQUID) magnetometers in key areas of biomagnetism. The first-generation sensors are designed to transition OPM technology from a physics laboratory to researchers in the medical community. The laser and optical components are tightly integrated inside the sensor package, and the sensor is tethered to a dedicated electronics signal processing unit that enables automated and standalone operation inside a magnetically shielded room.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631 · cited 1×
“Landmark work by Romalis and coworkers demonstrated OPM with sub-femtotesla level sensitivity using spin-exchange suppression in low magnetic fields [4].”
BackgroundBoto, E., Meyer, S. S., Shah, V., Alem, O., Knappe, S., Kruger, P., Fromhold, T. M., Lim, M., Glover, P. M., Morris, P. G., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.01.034 · Cited by 471 · cited 1×
“A number of research groups have collected data MCG and MEG data using QZFM validating the technology in a clinical setting [5], [12], [13].”
MethodSelf-citationMagnetocardiograms taken inside a shielded room with a superconducting point-contact magnetometer
Cohen, D., Edelsack, E. A., & Zimmerman, J. E. (1970) · Applied Physics Letters · doi:10.1063/1.1653195 · Cited by 361
A compact, high performance atomic magnetometer for biomedical applications
Shah, V. K., & Wakai, R. T. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/22/8153 · Cited by 322
Self-citation
Cited by
Optically pumped magnetometers: from quantum origins to multi-channel magnetoencephalography
Tierney, T. M., Holmes, N., Mellor, S., López, J. D., Roberts, G., Hill, R. M., Boto, E., Leggett, J., Shah, V., Brookes, M. J., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.05.063 · Cited by 400
Self-citationOn-scalp MEG system utilizing an actively shielded array of optically-pumped magnetometers
Iivanainen, J., Zetter, R., Grön, M., Hakkarainen, K., & Parkkonen, L. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.03.022 · Cited by 269
Holmes, N., Leggett, J., Boto, E., Roberts, G., Hill, R. M., Tierney, T. M., Shah, V., Barnes, G. R., Brookes, M. J., & Bowtell, R. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.07.028 · Cited by 250
Self-citationHolmes, N., Tierney, T. M., Leggett, J., Boto, E., Mellor, S., Roberts, G., Hill, R. M., Shah, V., Barnes, G. R., Brookes, M. J., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-50697-w · Cited by 163
Self-citationCan EEG and MEG detect signals from the human cerebellum?
Andersen, L. M., Jerbi, K., & Dalal, S. S. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116817 · Cited by 142
Towards OPM-MEG in a Virtual Reality Environment
Roberts, G., Holmes, N., Alexander, N., Boto, E., Leggett, J., Hill, R. M., Shah, V., Rea, M., Vaughan, R., Maguire, E. A., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.06.010 · Cited by 128
“…the applicability of OPMs in MEG (Borna et al., 2017; Boto et al., 2018; Johnson et al., 2013; Kamada et al., 2015) and recent developments have seen the introduction of small (Sander et al., 2012) and lightweight commercial OPMs (Osborne et al., 2018), which can be mounted on the scalp.”
BackgroundSelf-citationWearable neuroimaging: Combining and contrasting magnetoencephalography and electroencephalography
Boto, E., Seedat, Z. A., Holmes, N., Leggett, J., Hill, R. M., Roberts, G., Shah, V., Fromhold, T. M., Mullinger, K. J., Tierney, T. M., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116099 · Cited by 136
Self-citationA lightweight magnetically shielded room with active shielding
Holmes, N., Rea, M., Chalmers, J., Leggett, J., Edwards, L. J., Nell, P., Pink, S., Patel, P., Wood, J., Murby, N., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-17346-1 · Cited by 121
Self-citationUsing OPMs to measure neural activity in standing, mobile participants
Seymour, R. A., Alexander, N., Mellor, S., O'Neill, G. C., Tierney, T. M., Barnes, G. R., & Maguire, E. A. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118604 · Cited by 102
Naturalistic Hyperscanning with Wearable Magnetoencephalography
Holmes, N., Rea, M., Hill, R. M., Boto, E., Leggett, J., Edwards, L. J., Rhodes, N., Shah, V., Osborne, J., Fromhold, T. M., et al. (2023) · Sensors · doi:10.3390/s23125454 · Cited by 52
“Up to 50, second generation, QuSpin Inc. (Colorado, USA) zero-field magnetometers are available for array formation (see Tierney et al. (Tierney et al., 2019) for a review of OPM physics and Osborne et al. (Shah et al., 2018) for specific details of the QuSpin sensor).”
BackgroundMethodInfluentialSelf-citationA modular optically pumped magnetometer system
Coussens, T., Gialopsou, A., Abel, C., Bason, M. G., James, T. M., Evans, W., Woodley, M. T. M., Nightingale, D., Nicolau, D., Page, L., et al. (2024) · Quantum Science and Technology · doi:10.1088/2058-9565/ad4e60 · Cited by 11
“Further gains could be made in the low-frequency domain by implementing active feedback on vapour cell temperature and laser power.”
Background
Metadata
- Authors
- Shah, V., Osborne, J., Orton, J., & Alem, O.
- Venue
- Steep Dispersion Engineering and Opto-Atomic Precision Metrology XI
- Publisher
- SPIE
- Published
- 2018-02-22
- Pages
- 51
- OpenAlex
- W2789291094
- Cited by
- 173
- References
- 4
- FWCI
- 63.56
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.