Quantitative comparison of direct phase retrieval algorithms in in‐line phase tomography
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
A well‐known problem in x‐ray microcomputed tomography is low sensitivity. Phase contrast imaging offers an increase of sensitivity of up to a factor of in the hard x‐ray region, which makes it possible to image soft tissue and small density variations. If a sufficiently coherent x‐ray beam, such as that obtained from a third generation synchrotron, is used, phase contrast can be obtained by simply moving the detector downstream of the imaged object. This setup is known as in‐line or propagation based phase contrast imaging. A quantitative relationship exists between the phase shift induced by the object and the recorded intensity and inversion of this relationship is called phase retrieval. Since the phase shift is proportional to projections through the three‐dimensional refractive index distribution in the object, once the phase is retrieved, the refractive index can be reconstructed by using the phase as input to a tomographic reconstruction algorithm. A comparison between four phase retrieval algorithms is presented. The algorithms are based on the transport of intensity equation (TIE), transport of intensity equation for weak absorption, the contrast transfer function (CTF), and a mixed approach between the CTF and TIE, respectively. The compared methods all rely on linearization of the relationship between phase shift and recorded intensity to yield fast phase retrieval algorithms. The phase retrieval algorithms are compared using both simulated and experimental data, acquired at the European Synchrotron Radiation Facility third generation synchrotron light source. The algorithms are evaluated in terms of two different reconstruction error metrics. While being slightly less computationally effective, the mixed approach shows the best performance in terms of the chosen criteria.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to Fourier Optics
Sutton, P. (1996) · Quantum and Semiclassical Optics: Journal of the European Optical Society Part B · doi:10.1088/1355-5111/8/5/014 · Cited by 4,934
GABOR, D. (1948) · Nature · doi:10.1038/161777a0 · Cited by 4,548
Principles of Computerized Tomographic Imaging
Kak, A. C., Slaney, M., & Wang, G. (2002) · Medical Physics · doi:10.1118/1.1455742 · Cited by 1,877
Phase-contrast imaging using polychromatic hard X-rays
Wilkins, S. W., Gureyev, T. E., Gao, D., Pogany, A., & Stevenson, A. W. (1996) · Nature · doi:10.1038/384335a0 · Cited by 1,766
Snigirev, A., Snigireva, I., Kohn, V., Kuznetsov, S., & Schelokov, I. (1995) · Review of Scientific Instruments · doi:10.1063/1.1146073 · Cited by 1,493
Deterministic phase retrieval: a Green’s function solution
Teague, M. R. (1983) · Journal of the Optical Society of America · doi:10.1364/josa.73.001434 · Cited by 1,419
Diffraction enhanced x-ray imaging
Chapman, D., Thomlinson, W., Johnston, R. E., Washburn, D., Pisano, E., Gmür, N., Zhong, Z., Menk, R., Arfelli, F., & Sayers, D. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/11/001 · Cited by 1,098
Cloetens, P., Ludwig, W., Baruchel, J., Van Dyck, D., Van Landuyt, J., Guigay, J. P., & Schlenker, M. (1999) · Applied Physics Letters · doi:10.1063/1.125225 · Cited by 1,078
Self-citationBonse, U., & Hart, M. (1965) · Applied Physics Letters · doi:10.1063/1.1754212 · Cited by 1,057
Phase objects in synchrotron radiation hard x-ray imaging
Cloetens, P., Barrett, R., Baruchel, J., Guigay, J.-P., & Schlenker, M. (1996) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/29/1/023 · Cited by 853
Self-citationNoninterferometric Phase Imaging with Partially Coherent Light
Paganin, D., & Nugent, K. A. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.2586 · Cited by 770
Quantitative Phase Imaging Using Hard X Rays
Nugent, K. A., Gureyev, T. E., Cookson, D. F., Paganin, D., & Barnea, Z. (1996) · Physical Review Letters · doi:10.1103/physrevlett.77.2961 · Cited by 675
Observation of microstructure and damage in materials by phase sensitive radiography and tomography
Cloetens, P., Pateyron-Salomé, M., Buffière, J. Y., Peix, G., Baruchel, J., Peyrin, F., & Schlenker, M. (1997) · Journal of Applied Physics · doi:10.1063/1.364374 · Cited by 538
Self-citationTafforeau, P., Boistel, R., Boller, E., Bravin, A., Brunet, M., Chaimanee, Y., Cloetens, P., Feist, M., Hoszowska, J., Jaeger, J.-J., et al. (2006) · Applied Physics A · doi:10.1007/s00339-006-3507-2 · Cited by 456
Self-citationPhase retrieval from series of images obtained by defocus variation
Allen, L. J., & Oxley, M. P. (2001) · Optics Communications · doi:10.1016/s0030-4018(01)01556-5 · Cited by 423
Labiche, J.-C., Mathon, O., Pascarelli, S., Newton, M. A., Ferre, G. G., Curfs, C., Vaughan, G., Homs, A., & Carreiras, D. F. (2007) · Review of Scientific Instruments · doi:10.1063/1.2783112 · Cited by 394
How Neanderthal molar teeth grew
Macchiarelli, R., Bondioli, L., Debénath, A., Mazurier, A., Tournepiche, J.-F., Birch, W., & Dean, M. C. (2006) · Nature · doi:10.1038/nature05314 · Cited by 276
A synchrotron radiation microtomography system for the analysis of trabecular bone samples
Salomé, M., Peyrin, F., Cloetens, P., Odet, C., Laval-Jeantet, A.-M., Baruchel, J., & Spanne, P. (1999) · Medical Physics · doi:10.1118/1.598736 · Cited by 275
Self-citationNuzzo, S., Peyrin, F., Cloetens, P., Baruchel, J., & Boivin, G. (2002) · Medical Physics · doi:10.1118/1.1513161 · Cited by 233
Self-citationFundamental image quality limits for microcomputed tomography in small animals
Ford, N. L., Thornton, M. M., & Holdsworth, D. W. (2003) · Medical Physics · doi:10.1118/1.1617353 · Cited by 210
Guigay, J. P., Langer, M., Boistel, R., & Cloetens, P. (2007) · Optics Letters · doi:10.1364/ol.32.001617 · Cited by 199
Self-citationMicro‐CT with respiratory and cardiac gating
Badea, C., Hedlund, L. W., & Johnson, G. A. (2004) · Medical Physics · doi:10.1118/1.1812604 · Cited by 196
Theory of quantitative phase-contrast computed tomography
Bronnikov, A. V. (2002) · Journal of the Optical Society of America A · doi:10.1364/josaa.19.000472 · Cited by 195
Linear algorithms for phase retrieval in the Fresnel region
Gureyev, T. E., Pogany, A., Paganin, D. M., & Wilkins, S. W. (2004) · Optics Communications · doi:10.1016/j.optcom.2003.12.020 · Cited by 182
On the transport of intensity technique for phase retrieval
Beleggia, M., Schofield, M. A., Volkov, V. V., & Zhu, Y. (2004) · Ultramicroscopy · doi:10.1016/j.ultramic.2004.08.004 · Cited by 174
Implementation of a fast method for high resolution phase contrast tomography
Groso, A., Abela, R., & Stampanoni, M. (2006) · Optics Express · doi:10.1364/oe.14.008103 · Cited by 167
X-ray microtomography of bones and teeth
Davis, G. R., & Wong, F. S. L. (1996) · Physiological Measurement · doi:10.1088/0967-3334/17/3/001 · Cited by 151
Paired gill slits in a fossil with a calcite skeleton
Alonso, P. D., Jacobson, A. G., & Jefferies, R. P. S. (2002) · Nature · doi:10.1038/nature00805 · Cited by 123
Prospective respiratory‐gated micro‐CT of free breathing rodents
Ford, N. L., Nikolov, H. N., Norley, C. J. D., Thornton, M. M., Foster, P. J., Drangova, M., & Holdsworth, D. W. (2005) · Medical Physics · doi:10.1118/1.2013007 · Cited by 111
Chappard, C., Basillais, A., Benhamou, L., Bonassie, A., Brunet-Imbault, B., Bonnet, N., & Peyrin, F. (2006) · Medical Physics · doi:10.1118/1.2256069 · Cited by 81
Self-citationQuantitative phase contrast tomography using coherent synchrotron radiation
Cloetens, P., Ludwig, W., Boller, É., Helfen, L., Salvo, L., Mache, R., & Schlenker, M. (2002) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.452867 · Cited by 71
Self-citation
Cited by
X-ray phase-contrast imaging: from pre-clinical applications towards clinics
Bravin, A., Coan, P., & Suortti, P. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/1/r1 · Cited by 846
Transport of intensity equation: a tutorial
Zuo, C., Li, J., Sun, J., Fan, Y., Zhang, J., Lu, L., Zhang, R., Wang, B., Huang, L., & Chen, Q. (2020) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106187 · Cited by 581
Coherent methods in the X-ray sciences
Nugent, K. A. (2010) · Advances in Physics · doi:10.1080/00018730903270926 · Cited by 476
Bale, H. A., Haboub, A., MacDowell, A. A., Nasiatka, J. R., Parkinson, D. Y., Cox, B. N., Marshall, D. B., & Ritchie, R. O. (2013) · Nature Materials · doi:10.1038/nmat3497 · Cited by 335
ANKAphase: software for single-distance phase retrieval from inline X-ray phase-contrast radiographs
Weitkamp, T., Haas, D., Wegrzynek, D., & Rack, A. (2011) · Journal of Synchrotron Radiation · doi:10.1107/s0909049511002895 · Cited by 278
Metadata
- Authors
- Langer, M., Cloetens, P., Guigay, J., & Peyrin, F.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2008-09-18
- Volume
- 35
- Issue
- 10
- Pages
- 4556-4566
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2066200146
- Cited by
- 179
- References
- 31
- FWCI
- 11.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.