Improved dual‐energy material discrimination for dual‐source CT by means of additional spectral filtration
Open accessAbstract
The use of additional spectral filtration for dual‐energy (DE) imaging using a dual‐source CT (DSCT) system was investigated and its effect on the material‐specific was evaluated for several clinically relevant materials. The x‐ray spectra, data acquisition, and reconstruction processes for a DSCT system (Siemens Definition) were simulated using information provided by the system manufacturer, resulting in virtual DE images. The factory‐installed filtration for the 80 kV spectrum was left unchanged to avoid any further reductions in tube output, and only the filtration for the high‐energy spectrum was modified. Only practical single‐element filter materials within the atomic number range of were evaluated, with the aim of maximizing the separation between the two spectra, while maintaining similar noise levels for high‐ and low‐energy images acquired at the same tube current. The differences between mean energies and the ratio of the 140 and 80 kV detector signals, each integrated below 80 keV, were evaluated. The simulations were performed for three attenuation scenarios: Head, body, and large body. The large body scenario was evaluated for the DE acquisition mode using the 100 and 140 kV spectra. The for calcium hydroxyapatite (simulating bone or calcifications), iodine, and iron were determined for CT images simulated using the modified and factory‐installed filtration. Several filter materials were found to perform well at proper thicknesses, with tin being a good practical choice. When image noise was matched between the low‐ and high‐energy images, the spectral difference in mean absorbed energy using tin was increased from 25.7 to 42.7 keV (head), from 28.6 to 44.1 keV (body), and from 20.2 to 30.2 keV (large body). The overlap of the signal spectra for energies below 80 keV was reduced from 78% to 31% (head), from 93% to 27% (body), and from 106% to 79% (large body). The for the body attenuation scenario increased from 1.45 to 1.91 (calcium), from 1.84 to 3.39 (iodine), and from 1.73 to 2.93 (iron) with the additional tin filtration compared to the factory filtration. This use of additional filtration for one of the x‐ray tubes used in dual‐source DECT dramatically increased the difference between material‐specific DE ratios, e.g., from 0.39 to 1.48 for calcium and iodine or from 0.28 to 1.02 for calcium and iron. Because the ability to discriminate between different materials in DE imaging depends primarily on the differences in DE ratios, this increase is expected to improve the performance of any material‐specific DECT imaging task. Furthermore, for the large patient size and in conjunction with a 100/140 kV acquisition, the use of additional filtration decreased noise in the low‐energy images and increased contrast in the DE image relative to that obtained with 80/140 kV and no additional filtration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Energy-selective reconstructions in X-ray computerised tomography
Alvarez, R. E., & Macovski, A. (1976) · Physics in Medicine & Biology · doi:10.1088/0031-9155/21/5/002 · Cited by 2,013
Material differentiation by dual energy CT: initial experience
Johnson, T. R. C., Krauß, B., Sedlmair, M., Grasruck, M., Bruder, H., Morhard, D., Fink, C., Weckbach, S., Lenhard, M., Schmidt, B., et al. (2007) · European Radiology · doi:10.1007/s00330-006-0517-6 · Cited by 1,510
Intraplaque Hemorrhage and Progression of Coronary Atheroma
Kolodgie, F. D., Gold, H. K., Burke, A. P., Fowler, D. R., Kruth, H. S., Weber, D. K., Farb, A., Guerrero, L. J., Hayase, M., Kutys, R., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035655 · Cited by 1,486
First performance evaluation of a dual-source CT (DSCT) system
Flohr, T. G., McCollough, C. H., Bruder, H., Petersilka, M., Gruber, K., Süβ, C., Grasruck, M., Stierstorfer, K., Krauss, B., Raupach, R., et al. (2006) · European Radiology · doi:10.1007/s00330-005-2919-2 · Cited by 1,413
Self-citationAn accurate method for computer‐generating tungsten anode x‐ray spectra from 30 to 140 kV
Boone, J. M., & Seibert, J. A. (1997) · Medical Physics · doi:10.1118/1.597953 · Cited by 706
Kalender, W. A. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/13/r03 · Cited by 689
Evaluation of a prototype dual‐energy computed tomographic apparatus. I. Phantom studies
Kalender, W. A., Perman, W. H., Vetter, J. R., & Klotz, E. (1986) · Medical Physics · doi:10.1118/1.595958 · Cited by 451
Dual Energy CT Characterization of Urinary Calculi: Initial In Vitro and Clinical Experience
Graser, A., Johnson, T. R. C., Bader, M., Staehler, M., Haseke, N., Nikolaou, K., Reiser, M. F., Stief, C. G., & Becker, C. R. (2008) · Investigative Radiology · doi:10.1097/rli.0b013e318157a144 · Cited by 341
Ruzsics, B., Lee, H., Zwerner, P. L., Gebregziabher, M., Costello, P., & Schoepf, U. J. (2008) · European Radiology · doi:10.1007/s00330-008-1022-x · Cited by 231
Noise considerations in dual energy CT scanning
Kelcz, F., Joseph, P. M., & Hilal, S. K. (1979) · Medical Physics · doi:10.1118/1.594520 · Cited by 221
Cited by
Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications
McCollough, C. H., Leng, S., Yu, L., & Fletcher, J. G. (2015) · Radiology · doi:10.1148/radiol.2015142631 · Cited by 1,598
Self-citationRadiation dose reduction in computed tomography: techniques and future perspective
Yu, L., Liu, X., Leng, S., Kofler, J. M., Ramirez-Giraldo, J. C., Qu, M., Christner, J., Fletcher, J. G., & McCollough, C. H. (2009) · Imaging in Medicine · doi:10.2217/iim.09.5 · Cited by 395
Self-citationState of the Art: Dual-Energy CT of the Abdomen
Marin, D., Boll, D. T., Mileto, A., & Nelson, R. C. (2014) · Radiology · doi:10.1148/radiol.14131480 · Cited by 368
Material Separation Using Dual-Energy CT: Current and Emerging Applications
Patino, M., Prochowski, A., Agrawal, M. D., Simeone, F. J., Gupta, R., Hahn, P. F., & Sahani, D. V. (2016) · RadioGraphics · doi:10.1148/rg.2016150220 · Cited by 328
McCollough, C. H., Chen, G. H., Kalender, W., Leng, S., Samei, E., Taguchi, K., Wang, G., Yu, L., & Pettigrew, R. I. (2012) · Radiology · doi:10.1148/radiol.12112265 · Cited by 276
Self-citation
Metadata
- Authors
- Primak, A. N., Ramirez Giraldo, J. C., Liu, X., Yu, L., & McCollough, C. H.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2009-03-25
- Volume
- 36
- Issue
- 4
- Pages
- 1359-1369
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2076677600
- Cited by
- 318
- References
- 13
- FWCI
- 13.78
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved dual‐energy material discrimination for dual‐source CT by means of additional spectral filtration. https://app.cochat.ai/papers/10.1118/1.3083567
- The paper
- Primak, A. N., Ramirez Giraldo, J. C., Liu, X., Yu, L., & McCollough, C. H. (2009). Improved dual‐energy material discrimination for dual‐source CT by means of additional spectral filtration. Medical Physics. https://doi.org/10.1118/1.3083567
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.