Physical Performance of the new hybrid PET/CT Discovery-690
Abstract
PURPOSE: The aim of this work was the assessment of the physical performance of the new hybrid PET∕CT system: Discovery-690. METHODS: The Discovery-690 combines a lutetium-yttrium-orthosilicate (LYSO) block detector designed PET tomograph with a 64-slice CT scanner. The system is further characterized by a dedicated powerful computing platform implementing fully 3D-PET iterative reconstruction algorithms. These algorithms can account for time of flight (TOF) information and∕or a 3D model of the PET point spread function (PSF). PET physical performance was measured following NEMA NU-2-2007 procedures. Furthermore, specific tests were used: (i) to measure the energy and timing resolution of the PET system and (ii) to evaluate image quality, by using phantoms representing different clinical conditions (e.g., brain and whole body). Data processing and reconstructions were performed as required by standard procedures. Further reconstructions were carried out to evaluate the performance of the new reconstruction algorithms. In particular, four algorithms were considered for the reconstruction of the PET data: (i) HD = standard configuration, without TOF and PSF, (ii) TOF = HD + TOF, (iii) PSF = HD + PSF, and (iv) TOFPSF = HD + TOF + PSF. RESULTS: The transverse (axial) spatial resolution values were 4.70 (4.74) mm and 5.06 (5.55) mm at 1 cm and 10 cm off axis, respectively. Sensitivity (average between 0 and 10 cm) was 7.5 cps∕kBq. The noise equivalent count rate (NECR) peak was 139.1 kcps at 29.0 kBq∕ml. The scatter fraction at the NECR peak was 37%. The correction accuracy for the dead time losses and random event counts had a maximum absolute error below the NECR peak of 2.09%. The average energy and timing resolution were 12.4% and 544.3 ps, respectively. PET image quality was evaluated with the NEMA IEC Body phantom by using four reconstruction algorithms (HD, TOF, PSF, and TOFPSF), as previously described. The hot contrast (after 3 iterations and for a lesion∕background activity ratio of 4:1) for the spheres of 10, 13, 17, and 22 mm was (HD) 29.8, 45.4, 55.4, and 68.1%; (TOF) 39.9, 53.5, 62.7, and 72.2%; (PSF) 28.3, 47.3, 60.4, and 71.8%; (TOFPSF) 43.8, 62.9, 70.6, and 76.4%. The cold contrast for the spheres of 28 and 37 mm was (HD) 62.4 and 65.2%; (TOF) 77.1 and 81.4%; (PSF) 62.0 and 65.2%; (TOFPSF) 77.3 and 81.6%. Similar hot and cold contrast trends were found during the analyses of other phantoms representing different clinical conditions (brain and whole body). Nevertheless, the authors observed a predominant role of either TOF or PSF, depending on the specific characteristics and dimensions of the phantoms. CONCLUSIONS: Discovery-690 shows very good PET physical performance for all the standard NEMA NU-2-2007 measurements. Furthermore, the new reconstruction algorithms available for PET data (TOF and PSF) allow further improvements of the D-690 image quality performance both qualitatively and quantitatively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A combined PET/CT scanner for clinical oncology.
Beyer, T., Townsend, D. W., Brun, T., Kinahan, P. E., Charron, M., Roddy, R., Jerin, J., Young, J., Byars, L. G., & Nutt, R. (2000) · PubMed · Cited by 1,659
Analytic 3D image reconstruction using all detected events
Kinahan, P. E., & Rogers, J. G. (1989) · IEEE Transactions on Nuclear Science · doi:10.1109/23.34585 · Cited by 767
Surti, S., Kuhn, A., Werner, M. E., Perkins, A. E., Kolthammer, J. A., & Karp, J. S. (2007) · PubMed · Cited by 639
High-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner
Qi, J., Leahy, R. M., Cherry, S. R., Chatziioannou, A., & Farquhar, T. H. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/4/027 · Cited by 635
Benefit of Time-of-Flight in PET: Experimental and Clinical Results
Karp, J. S., Surti, S., Daube-Witherspoon, M. E., & Muehllehner, G. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.044834 · Cited by 584
Strother, S. C., Casey, M. E., & Hoffman, E. J. (1990) · IEEE Transactions on Nuclear Science · doi:10.1109/23.106715 · Cited by 549
Fully 3-D PET reconstruction with system matrix derived from point source measurements
Panin, V. Y., Kehren, F., Michel, C., & Casey, M. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.876171 · Cited by 536
Physical and clinical performance of the mCT time-of-flight PET/CT scanner
Jakoby, B. W., Bercier, Y., Conti, M., Casey, M. E., Bendriem, B., & Townsend, D. W. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/8/004 · Cited by 492
The use of PET in Alzheimer disease
Nordberg, A., Rinne, J. O., Kadir, A., & Långström, B. (2010) · Nature Reviews Neurology · doi:10.1038/nrneurol.2009.217 · Cited by 449
Noise and Edge Artifacts in Maximum-Likelihood Reconstructions for Emission Tomography
Snyder, D. L., Miller, M. I., Thomas, L. J., & Politte, D. G. (1987) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1987.4307831 · Cited by 421
Treatment of axial data in three-dimensional PET.
Daube-Witherspoon, M. E., & Muehllehner, G. (1987) · PubMed · Cited by 357
Time-of-flight positron emission tomography: status relative to conventional PET.
Budinger, T. F. (1983) · PubMed · Cited by 283
Impact of Time-of-Flight on PET Tumor Detection
Kadrmas, D. J., Casey, M. E., Conti, M., Jakoby, B. W., Lois, C., & Townsend, D. W. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.063016 · Cited by 277
State of the art and challenges of time-of-flight PET
Conti, M. (2009) · Physica Medica · doi:10.1016/j.ejmp.2008.10.001 · Cited by 274
An Assessment of the Impact of Incorporating Time-of-Flight Information into Clinical PET/CT Imaging
Lois, C., Jakoby, B. W., Long, M. J., Hubner, K. F., Barker, D. W., Casey, M. E., Conti, M., Panin, V. Y., Kadrmas, D. J., & Townsend, D. W. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.068098 · Cited by 265
Impact of Image-Space Resolution Modeling for Studies with the High-Resolution Research Tomograph
Sureau, F. C., Reader, A. J., Comtat, C., Leroy, C., Ribeiro, M.-J., Buvat, I., & Trébossen, R. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.045351 · Cited by 237
Scintillation crystals for PET.
Melcher, C. L. (2000) · PubMed · Cited by 228
Application and Evaluation of a Measured Spatially Variant System Model for PET Image Reconstruction
Alessio, A. M., Stearns, C. W., Tong, S., Ross, S. G., Kohlmyer, S., Ganin, A., & Kinahan, P. E. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2040188 · Cited by 215
Recent advances and future advances in time-of-flight PET
Moses, W. W. (2007) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2007.06.038 · Cited by 205
EM algorithm system modeling by image-space techniques for PET reconstruction
Reader, A. J., Julyan, P. J., Williams, H., Hastings, D. L., & Zweit, J. (2003) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2003.817327 · Cited by 191
Tong, S., Alessio, A. M., & Kinahan, P. E. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/5/013 · Cited by 190
Modeling and incorporation of system response functions in 3-D whole body PET
Alessio, A. M., Kinahan, P. E., & Lewellen, T. K. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.873222 · Cited by 176
Mawlawi, O. R., Podoloff, D. A., Kohlmyer, S. G., Williams, J. J., Stearns, C. W., Culp, R. F., & Macapinlac, H. A. (2004) · PubMed · Cited by 172
Lewellen, T. K. (1998) · Seminars in Nuclear Medicine · doi:10.1016/s0001-2998(98)80031-7 · Cited by 160
Performance of the new generation of whole-body PET/CT scanners: Discovery STE and Discovery VCT
Teräs, M., Tolvanen, T., Johansson, J. J., Williams, J. J., & Knuuti, J. (2007) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-007-0493-3 · Cited by 146
Image-based point spread function implementation in a fully 3D OSEM reconstruction algorithm for PET
Rapisarda, E., Bettinardi, V, Thielemans, K., & Gilardi, M. C. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/14/012 · Cited by 142
Self-citationPerformance evaluation of the new whole-body PET/CT scanner: Discovery ST
Bettinardi, V., Danna, M., Savi, A., Lecchi, M., Castiglioni, I., Gilardi, M. C., Bammer, H., Lucignani, G., & Fazio, F. (2004) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-003-1444-2 · Cited by 120
Self-citationThe imaging performance of a LaBr3-based PET scanner
Daube-Witherspoon, M. E., Surti, S., Perkins, A. E., Kyba, C. C. M., Wiener, R. I., Werner, M. E., Kulp, R. R., & Karp, J. S. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/1/004 · Cited by 120
Photon Time-of-Flight-Assisted Positron Emission Tomography
Ter-Pogossian, M. M., Mullani, N. A., Ficke, D. C., Markham, J., & Snyder, D. L. (1981) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198104000-00014 · Cited by 116
POTENTIAL ADVANTAGES OF A CESIUM FLUORIDE SCINTILLATOR FOR A TIME-OF-FLIGHT POSITRON CAMERA
Allemand, R., Gressel, O., Vacher, J., & Sank, V. J. (1980) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198008000-00054 · Cited by 116
Comparison of Fast Scintillators With TOF PET Potential
Conti, M., Eriksson, L., Rothfuß, H., & Melcher, C. L. (2009) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2008.2009446 · Cited by 94
Assessment of myocardial perfusion and function with PET and PET/CT
Al-Mallah, M. H., Sitek, A., Moore, S. C., Carli, M. F. D., & Dorbala, S. (2010) · Journal of Nuclear Cardiology · doi:10.1007/s12350-010-9223-5 · Cited by 90
NEMA NU 2 performance tests for scanners with intrinsic radioactivity.
Watson, C. C., Casey, M., Eriksson, L., Mulnix, T., Adams, D., & Bendriem, B. (2004) · PubMed · Cited by 90
Experimental evaluation of a simple lesion detection task with time-of-flight PET
Surti, S., & Karp, J. S. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/2/013 · Cited by 87
Image improvement and design optimization of the time-of-flight PET.
Wong, W. H. M., Mullani, N. A., Philippe, E. A., Hartz, R. K., & Gould, K. L. (1983) · PubMed · Cited by 81
Analytic system matrix resolution modeling in PET: an application to Rb-82 cardiac imaging
Rahmim, A., Tang, J., Lodge, M. A., Lashkari, S., Ay, M. R., Läutamaki, R., Tsui, B. M. W., & Bengel, F. M. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/21/004 · Cited by 80
Tohme, M. S., & Qi, J. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/12/007 · Cited by 78
Positron Emission Tomography/Computed Tomography: The Current Technology and Applications
Mittra, E., & Quon, A. S. W. (2009) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2008.10.005 · Cited by 77
Random coincidence estimation from single event rates on the Discovery ST PET/CT scanner
Stearns, C. W., McDaniel, D. L., Kohlmyer, S. G., Arul, P. R., Geiser, B. P., & SHANMUGAM, V. M. (2004) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2003.1352545 · Cited by 72
Target-Specific PET Probes for Neurodegenerative Disorders Related to Dementia
Kadir, A., & Nordberg, A. K. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.077164 · Cited by 70
PET/CT today: System and its impact on cancer diagnosis
Tsukamoto, E., & Ochi, S. (2006) · Annals of Nuclear Medicine · doi:10.1007/bf02984642 · Cited by 68
Feasibility of time-of-flight reconstruction in positron emission tomography.
Mullani, N. A., Markham, J., & Ter‐Pogossian, M. M. (1980) · PubMed · Cited by 68
The Challenge of Detector Designs for PET
Lewellen, T. K. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.10.4741 · Cited by 53
Dual-modality PET/CT instrumentation—Today and tomorrow
Lonsdale, M. N., & Beyer, T. (2010) · European Journal of Radiology · doi:10.1016/j.ejrad.2009.12.021 · Cited by 49
Geometrical and Monte Carlo projectors in 3D PET reconstruction
Aguiar, P., Rafecas, M., Ortuño, J. E., Kontaxakis, G., Santos, A., Pavı́a, J., & Ros, D. (2010) · Medical Physics · doi:10.1118/1.3501884 · Cited by 45
Impact of PSF modelling on the convergence rate and edge behaviour of EM images in PET
Thielemans, K., Asma, E., Ahn, S., Manjeshwar, R. M., Deller, T. W., Ross, S., Stearns, C. W., & Ganin, A. (2010) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2010.5874409 · Cited by 43
Guludec, D. L., Läutamaki, R., Knuuti, J. M., Bax, J. J., & Bengel, F. M. (2008) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-0859-1 · Cited by 40
Performance measurements for the PET/CT Discovery‐600 using NEMA NU 2‐2007 standards
Ponti, E. D., Morzenti, S., Guerra, L., Pasquali, C., Arosio, M., Bettinardi, V., Crespi, A., Gilardi, M. C., & Messa, C. (2011) · Medical Physics · doi:10.1118/1.3544655 · Cited by 40
Self-citationA fully 3D iterative image reconstruction algorithm incorporating data corrections
Iatrou, M., Ross, S. G., Manjeshwar, R. M., & Stearns, C. W. (2005) · IEEE Symposium Conference Record Nuclear Science 2004. · doi:10.1109/nssmic.2004.1462761 · Cited by 40
3D implementation of Scatter Estimation in 3D PET
Iatrou, M., Manjeshwar, R. M., Ross, S. G., Thielemans, K., & Stearns, C. W. (2006) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2006.354338 · Cited by 33
FEASIBILITY OF TIME-OF-FLIGHT RECONSTRUCTION IN POSITRON EMISSION TOMOGRAPHY
Mullani, N. A., Markham, J., Ter-Pogossian, M. M., & Sank, V. J. (1981) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198106000-00052 · Cited by 31
PET/CT challenge for the non-invasive diagnosis of coronary artery disease
Schwaiger, M., Ziegler, S. I., & Nekolla, S. G. (2010) · European Journal of Radiology · doi:10.1016/j.ejrad.2009.12.025 · Cited by 26
Cardiac hybrid imaging: state-of-the-art
Kaufmann, P. A. (2009) · Annals of Nuclear Medicine · doi:10.1007/s12149-009-0245-5 · Cited by 25
Performance comparison of two commercial BGO‐based PET/CT scanners using NEMA NU 2‐2001
Bolard, G., Prior, J. O., Modolo, L., Delaloye, A. B., Kosinski, M., Wastiel, C., Malterre, J., Bulling, S., Bochud, F. O., & Verdun, F. R. (2007) · Medical Physics · doi:10.1118/1.2739808 · Cited by 21
Optimization of time-of-flight reconstruction on Philips GEMINI TF
Vandenberghe, S., van Elmbt, L., Guerchaft, M., Clementel, E., Verhaeghe, J. A. J., Bol, A., Lemahieu, I. A., & Lonneux, M. (2009) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-009-1164-3 · Cited by 16
Detection performance analysis for time-of-flight PET
Cao, N., Huesman, R. H., Moses, W. W., & Qi, J. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/22/021 · Cited by 13
Properties of edge artifacts in PSF-based PET reconstruction
Tong, S., Alessio, A. M., Thielemans, K., Stearns, C. W., Ross, S., & Kinahan, P. E. (2010) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2010.5874493 · Cited by 11
Cited by
Spencer, B. A., Berg, E., Schmall, J. P., Omidvari, N., Leung, E. K., Abdelhafez, Y. G., Tang, S., Deng, Z., Dong, Y., Lv, Y., et al. (2021) · Journal of Nuclear Medicine · doi:10.2967/jnumed.120.250597 · Cited by 403
Recent developments in time-of-flight PET
Vandenberghe, S., Mikhaylova, E., D’Hoe, E., Mollet, P., & Karp, J. S. (2016) · EJNMMI Physics · doi:10.1186/s40658-016-0138-3 · Cited by 368
Iterative PET Image Reconstruction Using Convolutional Neural Network Representation
Gong, K., Guan, J., Kim, K., Zhang, X., Yang, J., Seo, Y., El Fakhri, G., Qi, J., & Li, Q. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2869871 · Cited by 274
Studies of a Next-Generation Silicon-Photomultiplier–Based Time-of-Flight PET/CT System
Hsu, D. F. C., Ilan, E., Peterson, W. T., Uribe, J., Lubberink, M., & Levin, C. S. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.189514 · Cited by 241
Akamatsu, G., Ishikawa, K., Mitsumoto, K., Taniguchi, T., Ohya, N., Baba, S., Abe, K., & Sasaki, M. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.103861 · Cited by 206
Metadata
- Authors
- Bettinardi, V., Presotto, L., Rapisarda, E., Picchio, M., Gianolli, L., & Gilardi, M. C.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2011-09-14
- Volume
- 38
- Issue
- 10
- Pages
- 5394-5411
- ISSN
- 0094-2405 (ISSN-L)
- OpenAlex
- W1970453159
- Cited by
- 380
- References
- 57
- FWCI
- 17.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.