We developed a pneumatically powered orthosis for the human ankle joint. The orthosis consisted of a carbon fiber shell, hinge joint, and two artificial pneumatic muscles. One artificial pneumatic muscle provided plantar flexion torque and the second one provided dorsiflexion torque. Computer software adjusted air pressure in each artificial muscle independently so that artificial muscle force was proportional to rectified low-pass-filtered electromyography (EMG) amplitude (i.e., proportional myoelectric control). Tibialis anterior EMG activated the artificial dorsiflexor and soleus EMG activated the artificial plantar flexor. We collected joint kinematic and artificial muscle force data as one healthy participant walked on a treadmill with the orthosis. Peak plantar flexor torque provided by the orthosis was 70 Nm, and peak dorsiflexor torque provided by the orthosis was 38 Nm. The orthosis could be useful for basic science studies on human locomotion or possibly for gait rehabilitation after neurological injury.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Use of Surface Electromyography in Biomechanics
De Luca, C. J. (1997) · Journal of Applied Biomechanics · doi:10.1123/jab.13.2.135 · Cited by 3,268
Treadmill training of paraplegic patients using a robotic orthosis.
Colombo, G., Joerg, M., Schreier, R., & Dietz, V. (2000) · PubMed · Cited by 1,292
Neptune, R. R., Kautz, S. A., & Zajac, F. E. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00105-1 · Cited by 1,132
Modeling and control of McKibben artificial muscle robot actuators
(2000) · IEEE Control Systems · doi:10.1109/37.833638 · Cited by 924
Adaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait
Blaya, J. A., & Herr, H. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.823266 · Cited by 741
Energetics of Actively Powered Locomotion Using the Simplest Walking Model
Kuo, A. D. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1427703 · Cited by 736
Donelan, J. M., Kram, R., & Kuo, A. D. (2002) · Journal of Experimental Biology · doi:10.1242/jeb.205.23.3717 · Cited by 670
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE???1984
Tipton, C. M. (1984) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198401000-00002 · Cited by 598
Locomotor Training After Human Spinal Cord Injury: A Series of Case Studies
Behrman, A. L., & Harkema, S. J. (2000) · Physical Therapy · doi:10.1093/ptj/80.7.688 · Cited by 593
Energy Generation and Absorption at the Ankle and Knee during Fast, Natural, and Slow Cadences
WINTER, D. A. (1983) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198305000-00021 · Cited by 579
Cited by
Lower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art
Dollar, A. M., & Herr, H. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.915453 · Cited by 1,327
Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation
Veneman, J. F., Kruidhof, R., Hekman, E. E. G., Ekkelenkamp, R., Van Asseldonk, E. H. F., & van der Kooij, H. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903919 · Cited by 1,280
Review of control strategies for robotic movement training after neurologic injury
Marchal-Crespo, L., & Reinkensmeyer, D. J. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-20 · Cited by 1,182
Biomechanical design of the Berkeley lower extremity exoskeleton (BLEEX)
Zoss, A. B., Kazerooni, H., & Chu, A. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.871087 · Cited by 1,170
State of the Art and Future Directions for Lower Limb Robotic Exoskeletons
Young, A. J., & Ferris, D. P. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2521160 · Cited by 901
Self-citationThe Effects of Adding Mass to the Legs on the Energetics and Biomechanics of Walking
BROWNING, R. C., MODICA, J. R., KRAM, R., & GOSWAMI, A. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31802b3562 · Cited by 603
Design and control of a bio-inspired soft wearable robotic device for ankle–foot rehabilitation
Park, Y.-L., Chen, B.-R., Pérez-Arancibia, N. O., Young, D., Stirling, L., Wood, R. J., Goldfield, E. C., & Nagpal, R. (2014) · Bioinspiration & Biomimetics · doi:10.1088/1748-3182/9/1/016007 · Cited by 497
“Powered AFOs have been proposed for supplementing weak muscles for both dorsiflexion and plantarflexion using McKibben pneumatic artificial muscle actuators [20, 21] and bidirectional pneumatic rotary actuators [22], combined with carbon fiber reinforced foot and leg frames.”
MethodExoskeletons and orthoses: classification, design challenges and future directions
Herr, H. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-21 · Cited by 477
Autonomous exoskeleton reduces metabolic cost of human walking during load carriage
Mooney, L. M., Rouse, E. J., & Herr, H. M. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-80 · Cited by 461
An improved powered ankle–foot orthosis using proportional myoelectric control
Ferris, D. P., Gordon, K. E., Sawicki, G. S., & Peethambaran, A. (2006) · Gait & Posture · doi:10.1016/j.gaitpost.2005.05.004 · Cited by 342
Self-citationRobot-Aided Neurorehabilitation: A Novel Robot for Ankle Rehabilitation
Roy, A., Krebs, H. I., Williams, D. J., Bever, C. T., Forrester, L. W., Macko, R. M., & Hogan, N. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2009.2019783 · Cited by 337
Learning to walk with a robotic ankle exoskeleton
Gordon, K. E., & Ferris, D. P. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.12.006 · Cited by 318
Self-citationJiménez-Fabián, R., & Verlinden, O. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.11.018 · Cited by 313
Mechanics and energetics of level walking with powered ankle exoskeletons
Sawicki, G. S., & Ferris, D. P. (2008) · Journal of Experimental Biology · doi:10.1242/jeb.009241 · Cited by 297
Self-citationAssistive mobility devices focusing on Smart Walkers: Classification and review
Martins, M. M., Santos, C. P., Frizera-Neto, A., & Ceres, R. (2012) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2011.11.015 · Cited by 260
Opportunities and challenges in the development of exoskeletons for locomotor assistance
Siviy, C., Baker, L. M., Quinlivan, B. T., Porciuncula, F., Swaminathan, K., Awad, L. N., & Walsh, C. J. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00984-1 · Cited by 258
A pneumatically powered knee-ankle-foot orthosis (KAFO) with myoelectric activation and inhibition
Sawicki, G. S., & Ferris, D. P. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-23 · Cited by 248
Self-citationMechanical performance of artificial pneumatic muscles to power an ankle–foot orthosis
Gordon, K. E., Sawicki, G. S., & Ferris, D. P. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.05.018 · Cited by 223
“Construction of earlier prototypes of the ankle–foot orthosis have been described in detail (Ferris et al., 2005, in press).”
MethodSelf-citationA Survey on applications of Pneumatic Artificial Muscles
Andrikopoulos, G., Nikolakopoulos, G., & Manesis, S. (2011) · 2011 19th Mediterranean Conference on Control & Automation (MED) · doi:10.1109/med.2011.5982983 · Cited by 199
“In [48], [49], [50], the authors developed a powered ankle–foot orthosis (Figure 4.”
BackgroundA PHYSIOLOGIST'S PERSPECTIVE ON ROBOTIC EXOSKELETONS FOR HUMAN LOCOMOTION
FERRIS, D. P., SAWICKI, G. S., & DALEY, M. A. (2007) · International Journal of Humanoid Robotics · doi:10.1142/s0219843607001138 · Cited by 185
Self-citationAn Upper-Limb Power-Assist Exoskeleton Using Proportional Myoelectric Control
Tang, Z., Zhang, K., Sun, S., Gao, Z., Zhang, L., & Yang, Z. (2014) · Sensors · doi:10.3390/s140406677 · Cited by 182
“Ferris [19–21] built an ankle-foot orthosis actuated by two pneumatic muscles for studying human walking and assisting gait rehabilitation using proportional myoelectric control.”
BackgroundSawicki, G. S., & Ferris, D. P. (2009) · Journal of Experimental Biology · doi:10.1242/jeb.017269 · Cited by 179
“Specific details on the design and performance of the exoskeletons are documented elsewhere (Ferris et al., 2005; Ferris et al., 2006; Gordon et al., 2006; Sawicki and Ferris, 2008; Sawicki et al., 2005).”
BackgroundSelf-citationDesign and Validation of a Torque-Controllable Knee Exoskeleton for Sit-to-Stand Assistance
Shepherd, M. K., & Rouse, E. J. (2017) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2017.2704521 · Cited by 174
“Despite a rich history in powered lower-limb exoskeletons [8]–[10], there are no suitable devices on the market to perform the proposed research.”
BackgroundBio-inspired active soft orthotic device for ankle foot pathologies
Park, Y.-L., Chen, B.-R., Young, D., Stirling, L., Wood, R. J., Goldfield, E., & Nagpal, R. (2011) · 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2011.6094933 · Cited by 130
“McKibben pneumatic artificial muscle actuators with carbon fiber reinforced foot and leg frames have been implemented for supplementing weak muscles for both dorsiflexion and plantarflexion [8], [11].”
MethodMartins, N. R. B., Angelica, A., Chakravarthy, K., Svidinenko, Y., Boehm, F. J., Opris, I., Lebedev, M. A., Swan, M., Garan, S. A., Rosenfeld, J. V., et al. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00112 · Cited by 91
Metadata
- Authors
- Ferris, D. P., Czerniecki, J. M., & Hannaford, B.
- Venue
- Journal of Applied Biomechanics
- Publisher
- Human Kinetics
- Published
- 2005-05
- Volume
- 21
- Issue
- 2
- Pages
- 189-197
- ISSN
- 1065-8483 (ISSN-L)
- 1543-2688
- OpenAlex
- W2130934472
- Cited by
- 376
- References
- 52
- FWCI
- 10.84
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.