Next-generation probes, particles, and proteins for neural interfacing
Open accessThe DOI matches its Crossref record; 247 of the 249 references it cites were found in a registry or an index.
Abstract
Multimodal and multidisciplinary approaches lead to next-generation technologies for reading and modulating neural function.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
![Fig. 1 Electrical interface in neural tissue. (A) Equivalent circuit of electrode/tissue interface; in this case, recording is considered [that is, neurons acting as a voltage source (Ve) and use of an amplifier]. However, similar concepts apply for stimulation. (B) Influence of neuroinflammatory reaction (astroglial scar) on local electrical impedance. The neuroinflammatory response adversely affects the signal from the neurons and the spreading resistance and introduces a scar impedance (Zscar) due to the formation of a dense layer of inflammatory cells (ED1), astrocytes (GFAP), and a distancing of neurons (NeuN) from the recording site. Fluorescence image is reproduced, in part, from the study of Biran et al. (31). (C) Influence of enhanced electrode coatings on improving the impedance of the electrode itself. Nanostructuring of traditional electrode materials, use of CNTs/graphene, or conducting polymers (CPs) allow for intimate ion interaction with the electrode, allowing for a marked drop in impedance. The comparison of impedance and resulting stimulation profile for a given biphasic current pulse and recording quality [signal-to-noise ratio (SNR)] is shown for a flat electrode (gray, dotted) and for an electrode with an enhancing coating (black line; for example, CPs).](https://figures.cochat.ai/paper-figures/f10643b5fd4c4e14bc24a50543ca3bfd/next-generation-probes-particles-and-proteins-for-neural-interfacing-figure-1.jpg)







Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“As a material whose features resemble water-rich tissue in the human body, hydrogels can greatly reduce the inflammatory response of foreign objects, regulate cell or protein attachment, and prevent device failure in vivo,[52] which is important for implants.[53,54]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [54]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 201–247 of 247
Evolution of Physical and Electrochemical Properties of Polypyrrole during Extended Oxidation
Schlenoff, J. B., & Xu, H. (1992) · Journal of The Electrochemical Society · doi:10.1149/1.2221238 · Cited by 123 · cited 1×
“In addition, some organic electrode coatings, such as the CP polypyrrole (PPy), can overoxidize easily due to defective polymer backbone coupling (28).”
BackgroundMagnetogenetics: remote non-invasive magnetic activation of neuronal activity with a magnetoreceptor
Long, X., Ye, J., Zhao, D., & Zhang, S.-J. (2015) · 中国科学通报:英文版 · doi:10.1007/s11434-015-0902-0 · Cited by 121
Nakatsuji, H., Numata, T., Morone, N., Kaneko, S., Mori, Y., Imahori, H., & Murakami, T. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201505534 · Cited by 120
Skousen, J. L., Merriam, S. M. E., Srivannavit, O., Perlin, G., Wise, K. D., & Tresco, P. A. (2011) · Progress in Brain Research · doi:10.1016/b978-0-444-53815-4.00009-1 · Cited by 111
Bansal, A., Liu, H., Jayakumar, M. K. G., Andersson‐Engels, S., & Zhang, Y. (2016) · Small · doi:10.1002/smll.201503792 · Cited by 111
Induction of Calcium Influx in Cortical Neural Networks by Nanomagnetic Forces
Tay, A., Kunze, A., Murray, C., & Di Carlo, D. (2016) · ACS Nano · doi:10.1021/acsnano.5b07118 · Cited by 108
Lee, H. J., Son, Y., Kim, J., Lee, C. J., Yoon, E.-S., & Cho, I.-J. (2015) · Lab on a Chip · doi:10.1039/c4lc01321b · Cited by 105
Optical Stimulation of Neurons
C. Thompson, A., R. Stoddart, P., & Jansen, E. D. (2015) · Current Molecular Imaging · doi:10.2174/2211555203666141117220611 · Cited by 105 · cited 1×
“For example, short-pulse IR light has been demonstrated for photothermal stimulation as a result of thermally sensitive ion channels or due to a change in cell capacitance (159).”
BackgroundConducting Polymer Electrodes for Electroencephalography
Leleux, P., Badier, J., Rivnay, J., Bénar, C., Hervé, T., Chauvel, P., & Malliaras, G. G. (2014) · Advanced Healthcare Materials · doi:10.1002/adhm.201300311 · Cited by 103
Self-citationMarshall, J. D., & Schnitzer, M. J. (2013) · ACS Nano · doi:10.1021/nn401410k · Cited by 102 · cited 1×
“Similar to voltage-sensitive dyes, in concept, inorganic quantum dots have also been proposed as voltage sensors because of their superior photo-stability (107, 108).”
BackgroundMechanically adaptive nanocomposites for neural interfacing
Capadona, J. R., Tyler, D. J., Zorman, C. A., Rowan, S. J., & Weder, C. (2012) · MRS Bulletin · doi:10.1557/mrs.2012.97 · Cited by 101
Son, Y., Jenny Lee, H., Kim, J., Shin, H., Choi, N., Justin Lee, C., Yoon, E.-S., Yoon, E., Wise, K. D., Geun Kim, T., et al. (2015) · Scientific Reports · doi:10.1038/srep15466 · Cited by 101
A polymer-based neural microimplant for optogenetic applications: design and first in vivo study
Rubehn, B., Wolff, S. B. E., Tovote, P., Lüthi, A., & Stieglitz, T. (2013) · Lab on a Chip · doi:10.1039/c2lc40874k · Cited by 100 · cited 3×
“(56) withMEMS-based polymer probes provides two examples of the potential for combined optical, chemical (fluidic), and electrical bidirectional probes (55).”
BackgroundInfluentialRowland, C. E., Susumu, K., Stewart, M. H., Oh, E., Mäkinen, A. J., O’Shaughnessy, T. J., Kushto, G., Wolak, M. A., Erickson, J. S., L. Efros, A., et al. (2015) · Nano Letters · doi:10.1021/acs.nanolett.5b02725 · Cited by 97
Light-evoked hyperpolarization and silencing of neurons by conjugated polymers
Feyen, P., Colombo, E., Endeman, D., Nova, M., Laudato, L., Martino, N., Antognazza, M. R., Lanzani, G., Benfenati, F., & Ghezzi, D. (2016) · Scientific Reports · doi:10.1038/srep22718 · Cited by 97
Activation of the central nervous system induced by micro-magnetic stimulation
Park, H.-J., Bonmassar, G., Kaltenbach, J. A., Machado, A. G., Manzoor, N. F., & Gale, J. T. (2013) · Nature Communications · doi:10.1038/ncomms3463 · Cited by 94
The Brain Research Through Advancing Innovative Neurotechnologies (BRAIN) Initiative and Neurology
Bargmann, C. I., & Newsome, W. T. (2014) · JAMA Neurology · doi:10.1001/jamaneurol.2014.411 · Cited by 93
Guerrero, G., Siegel, M. S., Roska, B., Loots, E., & Isacoff, E. Y. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75361-7 · Cited by 93
MRI contrast agents for functional molecular imaging of brain activity
Jasanoff, A. (2007) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2007.11.002 · Cited by 90
Elastomeric and soft conducting microwires for implantable neural interfaces
Kolarcik, C. L., Luebben, S. D., Sapp, S. A., Hanner, J., Snyder, N., Kozai, T. D. Y., Chang, E., Nabity, J. A., Nabity, S. T., Lagenaur, C. F., et al. (2015) · Soft Matter · doi:10.1039/c5sm00174a · Cited by 88 · cited 1×
“For example, a PEDOT-based elastomeric composite can be extruded and later insulated to achieve microwires that are five orders of magnitude lower in the Young’s modulus than their tungsten counterparts (57).”
BackgroundDynamic imaging with MRI contrast agents: quantitative considerations
Shapiro, M. G., Atanasijevic, T., Faas, H., Westmeyer, G. G., & Jasanoff, A. (2006) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2005.12.033 · Cited by 87
A Fluorescent, Genetically-Encoded Voltage Probe Capable of Resolving Action Potentials
Barnett, L. M., Platiša, J., Popovic, M. A., Pieribone, V. A., & Hughes, T. E. (2012) · PLoS ONE · doi:10.1371/journal.pone.0043454 · Cited by 86
Lugo, K., Miao, X., Rieke, F., & Lin, L. Y. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.000447 · Cited by 84 · cited 1×
“However, this mode of stimulation still requires development for in vivo applications (157).”
BackgroundBenfenati, V., Martino, N., Antognazza, M. R., Pistone, A., Toffanin, S., Ferroni, S., Lanzani, G., & Muccini, M. (2013) · Advanced Healthcare Materials · doi:10.1002/adhm.201300179 · Cited by 80
Fendyur, A., Mazurski, N., Shappir, J., & Spira, M. E. (2011) · Frontiers in Neuroengineering · doi:10.3389/fneng.2011.00014 · Cited by 73
Manganese-Enhanced MRI: Biological Applications in Neuroscience
Malheiros, J. M., Paiva, F. F., Longo, B. M., Hamani, C., & Covolan, L. (2015) · Frontiers in Neurology · doi:10.3389/fneur.2015.00161 · Cited by 71
Nanotechnology and neurophysiology
Angle, M. R., Cui, B., & Melosh, N. A. (2015) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2015.03.014 · Cited by 71
Seidl, K., Herwik, S., Torfs, T., Neves, H. P., Paul, O., & Ruther, P. (2011) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2011.2167661 · Cited by 68 · cited 2×
“The literature on specific binding for biosensors is vast (94).”
BackgroundMethodNew approaches for CMOS-based devices for large-scale neural recording
Ruther, P., & Paul, O. (2015) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2014.10.007 · Cited by 62 · cited 2×
“To minimize the external electronics and improve recording quality, higher-level logic should be integrated into implantable devices, including amplifiers, spike detection and closed-loop capabilities, calibration, and other analog and digital circuitry (11, 93).”
BackgroundMethodGabrielsson, E. O., Janson, P., Tybrandt, K., Simon, D. T., & Berggren, M. (2014) · Advanced Materials · doi:10.1002/adma.201401258 · Cited by 55 · cited 1×
“OEIPs require a reservoir of solubilized ions and are often limited by the capacity of their driving source and target electrodes; however, the ability to continuously regenerate the electrodes has been proposed (102).”
BackgroundWietek, J., Broser, M., Krause, B. S., & Hegemann, P. (2016) · Journal of Biological Chemistry · doi:10.1074/jbc.m115.699637 · Cited by 55
Tanaka, J., Toku, K., Sakanaka, M., & Maeda, N. (1999) · Neuroscience Research · doi:10.1016/s0168-0102(99)00041-3 · Cited by 50 · cited 1×
“For example, complex ECM coatings such as fixed astrocyte ECMcan effectively reducemicroglial activation and can do so more effectively than individual ECM components such as laminin or fibronectin (37).”
BackgroundOrganic electrochemical transistors for signal amplification in fast scan cyclic voltammetry
Tybrandt, K., Kollipara, S. B., & Magnus Berggren, A. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.01.097 · Cited by 48 · cited 1×
“Coupling FSCV with an electrochemical transistor may overcome these hurdles and has been demonstrated formeasuringmicromolar dopamine concentrations (97).”
BackgroundGrandy, T. H., Greenfield, S. A., & Devonshire, I. M. (2012) · Journal of Neurophysiology · doi:10.1152/jn.00512.2011 · Cited by 41
Lopez-Izquierdo, A., Warren, M., Riedel, M., Cho, S., Lai, S., Lux, R. L., Spitzer, K. W., Benjamin, I. J., Tristani-Firouzi, M., & Jou, C. J. (2014) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00344.2014 · Cited by 37 · cited 1×
“VSDI has been shown to work in stem cell–derived human tissues (126); however, characterized voltage-sensitive dyes have not been approved by the U.”
BackgroundSommakia, S., Gaire, J., Rickus, J. L., & Otto, K. J. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00033 · Cited by 32
Gigaohm resistance membrane seals with stealth probe electrodes
Verma, P., & Melosh, N. A. (2010) · Applied Physics Letters · doi:10.1063/1.3464954 · Cited by 28
Is there a path beyond BOLD? Molecular imaging of brain function
Koretsky, A. P. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.02.076 · Cited by 28 · cited 1×
“To address these limitations, several other molecular imaging methods have been developed to monitor brain activity (188, 191, 192).”
MethodWeld line improvement of short fiber reinforced thermoplastics with a movable flow obstacle
Janko, M., Spiegl, B., Kaufmann, A., Lucyshyn, T., & Holzer, C. (2015) · Journal of Applied Polymer Science · doi:10.1002/app.42025 · Cited by 24
Wireless Activation of Neurons in Brain Slices Using Nanostructured Semiconductor Photoelectrodes
Zhao, Y., Larimer, P., Pressler, R. T., Strowbridge, B. W., & Burda, C. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200806093 · Cited by 23
Bioengineered Probes for Molecular Magnetic Resonance Imaging in the Nervous System
Hsieh, V., & Jasanoff, A. (2012) · ACS Chemical Neuroscience · doi:10.1021/cn300059r · Cited by 21
Quantum dots for electrical stimulation of neural cells
Winter, J. O., Gomez, N. V., Korgel, B. A., & Schmidt, C. E. (2005) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.602363 · Cited by 21 · cited 1×
“Semiconducting nanoparticle stimulation approaches (149, 150), on the other hand,mayhave an additional benefit of being targeted to stimulate certain neural types (for example, ganglion cells).”
BackgroundKim, Y. T., Bridge, M. J., & Tresco, P. A. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2007.01.002 · Cited by 16 · cited 1×
“In addition to helping mechanical matching, hydrogels or other soft coatings can act as passive sinks that help effectively “clear” soluble inflammatory factors (13, 35).”
BackgroundSchwaerzle, M., Pothof, F., Paul, O., & Ruther, P. (2015) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2015.7181290 · Cited by 15
Bernstein, J. G., Allen, B. D., Guerra, A., & Boyden, E. S. (2015) · The Journal of Engineering · doi:10.1049/joe.2014.0304 · Cited by 14
Basics of PhotoactivationPreprint
Ellis‐Davies, G. C. R. (2009) · Cold Spring Harbor Protocols · doi:10.1101/pdb.top55 · Cited by 10 · cited 1×
“Many compounds have been developed for caging molecules with various properties; most of these are excited by 300- to 400-nmwavelengths (allowing use with a 700- to 800-nm, two-photon system) (129).”
BackgroundIndocyanine Green is a Voltage-Sensitive Fluorescent Dye
Treger, J. S., Priest, M. F., Iezzi, R., & Bezanilla, F. (2014) · Biophysical Journal · doi:10.1016/j.bpj.2013.11.4346 · Cited by 3 · cited 1×
“Food and Drug Administration (FDA) [nevertheless, note that an FDA-approved compound has recently been found to have voltage-sensitive optical properties (127)].”
Background
Research works printed but not linked: 1
- 10.1038/nmat3404 · DOI · Paper page
Cited by
Yuk, H., Lu, B., & Zhao, X. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00595h · Cited by 2,108
Organic electronics for neuromorphic computing
van de Burgt, Y., Melianas, A., Keene, S. T., Malliaras, G., & Salleo, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0103-3 · Cited by 1,104
“Additional development could further enhance the connection between synaptic memristive arrays and adaptive control of physiology and processes of cells, tissue and organs; and vice versa to enhance site-specific sensing and monitoring 106,110 .”
BackgroundSelf-citationLu, B., Yuk, H., Lin, S., Jian, N., Qu, K., Xu, J., & Zhao, X. (2019) · Nature Communications · doi:10.1038/s41467-019-09003-5 · Cited by 1,035
Soft and elastic hydrogel-based microelectronics for localized low-voltage neuromodulation
Liu, Y., Liu, J., Chen, S., Lei, T., Kim, Y., Niu, S., Wang, H., Wang, X., Foudeh, A. M., Tok, J. B.-H., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0335-6 · Cited by 811
Self-citationDesign of biodegradable, implantable devices towards clinical translation
Li, C., Guo, C., Fitzpatrick, V., Ibrahim, A., Zwierstra, M. J., Hanna, P., Lechtig, A., Nazarian, A., Lin, S. J., & Kaplan, D. L. (2019) · Nature Reviews Materials · doi:10.1038/s41578-019-0150-z · Cited by 808
Metadata
- Authors
- Rivnay, J., Wang, H., Fenno, L., Deisseroth, K., & Malliaras, G. G.
- Affiliations
- Northwestern University (US)
- Stanford University (US)
- Department of Bioelectronics, École Nationale Supérieure des Mines, CMP-EMSE, MOC, Gardanne 13541, France.
- Corresponding author
- Rivnay, Jonathan
- Venue
- Science Advances
- Published
- 2017-06-02
- Volume
- 3
- Issue
- 6
- Pages
- e1601649-e1601649
- ISSN
- 2375-2548 (ISSN-L)
- PMC
- PMC5466371
- OpenAlex
- W2624351657
- Semantic Scholar
- 39e8a8d75d6bb3089f0b224ff49a8767fab5ffbe
- Cited by
- 514
- References
- 249
- Citations by year
- 2026: 32 · 2025: 65 · 2024: 53 · 2023: 63 · 2022: 49 · 2021: 85 · 2020: 59 · 2019: 60 · 2018: 40 · 2017: 7
- FWCI
- 5.59
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- Science Advances (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Cambridge University Engineering Department Publications Database (submittedVersion)
- Funders
- Defense Advanced Research Projects Agency (ID0EQWBI15408, W911NF-14-2-0013)
- European Commission (ID0E31BI15409, OLIMPIA, ID0E5CCI15410, OrgBio)
- National Institutes of Health (ID0EALCI15411)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Social Sciences › Education › Undergraduate Neuroscience Education and Research
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Keywords
- neural interfaces, bidirectional neural interface, neurostimulation, nanoparticles, fluorescent dyes, neuronal signaling, neural prostheses, neurotherapeutics
- MeSH terms
- Animals, Brain, Humans, Nervous System Physiological Phenomena, Neurons, Physical Stimulation, Molecular Probe Techniques, Biosensing Techniques, Electrophysiological Phenomena, Molecular Imaging, Multimodal Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.