CoChat

Multilayered electronic transfer tattoo that can enable the crease amplification effect

Open access
Tang, Lixue, Shang, Jin, Jiang, Xingyu · 2021 · Science Advances

The DOI matches its Crossref record; 37 of the 38 references it cites were found in a registry or an index.

Abstract

Liquid metal electronic tattoo with the crease amplification effect increases the freedom and accuracy of motion recognition.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1126/sciadv.abe3778

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Schematic illustrations and optical images of the three-layered METT. (A) Exploded schematics of the METT containing three circuit layers. (B) Schematic illustrations of the layer-by-layer fabrication of the METT. (C) Optical image of the METT after transferring onto the skin; inset, the METT can be embedded into the creases on the finger joints. (D) Optical image of the METT for remotely controlling a robotic hand. Photo credit: Lixue Tang, Southern University of Science and Technology.
Fig. 1 Schematic illustrations and optical images of the three-layered METT. (A) Exploded schematics of the METT containing three circuit layers. (B) Schematic illustrations of the layer-by-layer fabrication of the METT. (C) Optical image of the METT after transferring onto the skin; inset, the METT can be embedded into the creases on the finger joints. (D) Optical image of the METT for remotely controlling a robotic hand. Photo credit: Lixue Tang, Southern University of Science and Technology.CC BY-NC · PubMed Central
Fig. 2 The METT is conformal and sticky, which can enable the crease amplification effect. (A) ΔR/R of the MPC in METT versus different tensile strains from 0 to 800%. Error bars in this paper represent SE. (B) ΔR/R of the MPC in METT versus tensile strains from 0 to 150%. (C) Real-time monitoring of the strain sensor in METT by stretching the METT from a strain of 0 to 50% for about 100 cycles. (D) Photograph of the METT embedded in the creases of fingers. (E) The METT can be embedded in the fingerprint. (F) Photograph of peeling off the METT from the skin. (G) Enlarged view of the METT attaching to the proximal interphalangeal joints (PIPs) during bending. (H) Schematic illustrations of the crease amplification effect; “a” presents the initial length of the suspended part. Dashed box, the crease model. (I) Schematic illustrations of different substrates with different thicknesses on the crease. The initial length of the suspended part, a1 < a2. Strain when bending, red > orange > yellow. (J) Photographs of the strain sensors on the skin of finger joints with reference. (K) A comparison of the output signals of the MPC strain sensors on different substrates with different thicknesses when bending the index finger to 105°. Photo credit: Lixue Tang, Southern University of Science and Technology.
Fig. 2 The METT is conformal and sticky, which can enable the crease amplification effect. (A) ΔR/R of the MPC in METT versus different tensile strains from 0 to 800%. Error bars in this paper represent SE. (B) ΔR/R of the MPC in METT versus tensile strains from 0 to 150%. (C) Real-time monitoring of the strain sensor in METT by stretching the METT from a strain of 0 to 50% for about 100 cycles. (D) Photograph of the METT embedded in the creases of fingers. (E) The METT can be embedded in the fingerprint. (F) Photograph of peeling off the METT from the skin. (G) Enlarged view of the METT attaching to the proximal interphalangeal joints (PIPs) during bending. (H) Schematic illustrations of the crease amplification effect; “a” presents the initial length of the suspended part. Dashed box, the crease model. (I) Schematic illustrations of different substrates with different thicknesses on the crease. The initial length of the suspended part, a1 < a2. Strain when bending, red > orange > yellow. (J) Photographs of the strain sensors on the skin of finger joints with reference. (K) A comparison of the output signals of the MPC strain sensors on different substrates with different thicknesses when bending the index finger to 105°. Photo credit: Lixue Tang, Southern University of Science and Technology.CC BY-NC · PubMed Central
Fig. 3 The scalability of the METT. (A) Optical image of the seven-layered heater. (B) The thermal image of the heater without deformation (left) and with 30% strain (right). (C) The numbers of the erupted liquid metal droplets depend on the thickness of the SBS layer after the stretch cycles. (D) Scanning electron microscopy (SEM) characterization of the surface of the SBS corresponding to (C); the thickness of the SBS in I (left) and II (right) is 4.8 and 18.13 μm, respectively. (E) SEM characterizations of the electric connection point. The dotted lines present the edge of the electric connection point, which is covered by liquid metal particles. (F) Cross section of a three-layered METT.
Fig. 3 The scalability of the METT. (A) Optical image of the seven-layered heater. (B) The thermal image of the heater without deformation (left) and with 30% strain (right). (C) The numbers of the erupted liquid metal droplets depend on the thickness of the SBS layer after the stretch cycles. (D) Scanning electron microscopy (SEM) characterization of the surface of the SBS corresponding to (C); the thickness of the SBS in I (left) and II (right) is 4.8 and 18.13 μm, respectively. (E) SEM characterizations of the electric connection point. The dotted lines present the edge of the electric connection point, which is covered by liquid metal particles. (F) Cross section of a three-layered METT.CC BY-NC · PubMed Central
Fig. 4 The METT can monitor the movements of the hand. (A) ΔR/R of strain sensors in different position versus angles. Inset: The schematic illustration of the measurement positions of the strain sensors. (B) Resistance response of the METT attached to PIP in different bending angles. (C) ΔR/R of strain sensors in the METT with different layers depending on the bending angles of the index PIP. (D) Schematic illustration of the measurement positions of the strain sensors. (E) Optical images of the three-layered METT attaching to the hand. (F) The thermal image of the three-layered METT on hand. (G) The real-time signal changes of the 15 strain sensors and temperature changes of the heater on the METT with different hand movements. Photo credit: Lixue Tang, Southern University of Science and Technology.
Fig. 4 The METT can monitor the movements of the hand. (A) ΔR/R of strain sensors in different position versus angles. Inset: The schematic illustration of the measurement positions of the strain sensors. (B) Resistance response of the METT attached to PIP in different bending angles. (C) ΔR/R of strain sensors in the METT with different layers depending on the bending angles of the index PIP. (D) Schematic illustration of the measurement positions of the strain sensors. (E) Optical images of the three-layered METT attaching to the hand. (F) The thermal image of the three-layered METT on hand. (G) The real-time signal changes of the 15 strain sensors and temperature changes of the heater on the METT with different hand movements. Photo credit: Lixue Tang, Southern University of Science and Technology.CC BY-NC · PubMed Central
Fig. 5 The METT can control the robotic hand remotely. (A) Photograph of transferring the tattoo onto the hand. (B) Photograph showing METT on the skin (left) and disposal glove (right). Dotted frame, the external contact pads. (C) System-level block diagram of the robot controlling system. (D) The METT can remotely control the movements of the robotic hand. Photo credit: Lixue Tang, Southern University of Science and Technology.
Fig. 5 The METT can control the robotic hand remotely. (A) Photograph of transferring the tattoo onto the hand. (B) Photograph showing METT on the skin (left) and disposal glove (right). Dotted frame, the external contact pads. (C) System-level block diagram of the robot controlling system. (D) The METT can remotely control the movements of the robotic hand. Photo credit: Lixue Tang, Southern University of Science and Technology.CC BY-NC · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 37 references

Cited by

Metadata

Authors
Tang, L., Shang, J., & Jiang, X.
Affiliations
  • Capital Medical University (CN)
  • National Center for Nanoscience and Technology (CN)
  • Southern University of Science and Technology (CN)
Corresponding author
Jiang, Xingyu
Venue
Science Advances
Published
2021-01-15
Volume
7
Issue
3
ISSN
2375-2548 (ISSN-L)
OpenAlex
W3119535577
Cited by
231
References
38
Citations by year
2026: 15 · 2025: 54 · 2024: 55 · 2023: 58 · 2022: 33 · 2021: 16
FWCI
12.30
Type
journal article
Language
en
Open access
Locations
  • Science Advances (publishedVersion, cc-by-nc)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
Funders
  • National Natural Science Foundation of China (21535001, 81730051, 21761142006)
  • National Key Research and Development Program of China Stem Cell and Translational Research (2018YFA0902600, 2017YFA0205901)
  • Tencent Foundation through the XPLORER PRIZE
  • Shenzhen Bay Laboratory (SZBL2019062801004)
  • High-level University Construction Fund from Shenzhen Government (No. G02386301, G02386401)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
Keywords
electronic tattoos, stretchable electronics, strain sensors, layer-by-layer assembly, motion monitoring, telerobotics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.